Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

DIS82.ACHANNAAX

DIS82.ACHANNAAX
Product family: External display and operation module
External display and operation module
VEGA DIS82.ACHANNAAX
External display and operation module;Scope Europe;Approval ATEX II 1G, 2G Ex ia IIC T6 Ga, Gb;Electronics Two-wire 4 ... 20 mA/HART;Housing Aluminium;Protection IP66/IP68 NEMA 6P (0.2bar);Cable entry / Connection ½NPT / Blind plug;Indicating/adjustment module (PLICSCOM) mounted;Mounting for wall mounting with Aluminium or StSt housing;Certificates No

Order Code:DIS82.ACHANNAAX

Name:External display and operation module

Configuration

CodeNameOrderSpecification
010ScopeAEurope
020ApprovalCATEX II 1G, 2G Ex ia IIC T6 Ga, Gb
030ElectronicsHTwo-wire 4 ... 20 mA/HART
050HousingAAluminium
060ProtectionNIP66/IP68 NEMA 6P (0.2bar)
070Cable entry / ConnectionN½NPT / Blind plug
080Indicating/adjustment module (PLICSCOM)Amounted
100MountingAfor wall mounting with Aluminium or StSt housing
110CertificatesXNo

Configuration Explained

This is a DIS82 external display and operating module, provides external display and adjustment for 4-20mA HART sensors, Europe version, with ATEX intrinsically safe approval II 1G, 2G Ex ia IIC T6, two-wire 4-20mA HART power supply, aluminium housing, IP66/68, ½ NPT entry with blind plug, wall mounted next to an aluminium or stainless steel housing, no need to climb the tank when the instrument is out of reach, suitable for on-site display in hazardous areas.

10 models · click to collapse