NPW-160 Total Phosphorus/Total Nitrogen Analyzer
Measuring principle:
Total phosphorus measurement (compliant with GB11893-89): Potassium persulfate is used as the oxidant to digest the water sample at 120°C for 30 min, converting phosphorus compounds into phosphate ions. The total phosphorus content in water is determined by the molybdenum blue spectrophotometric method (measuring wavelength: 700 nm).
Total nitrogen measurement (compliant with HJ636-2012): Potassium persulfate is used as the oxidant to digest the water sample at 120°C for 30 min, converting nitrogen compounds into nitrate ions. The pH of the sample solution is adjusted to 2-3, and the total nitrogen content in water is determined by UV spectrophotometric method (measuring wavelength: 220 nm, 275 nm turbidity correction: A = A220 - A275 × 2).
COD (UV) measurement: Dual-wavelength spectrophotometric method (UV 254 nm, visible light 546 nm).
Instrument features:
● The NPW-160 total nitrogen analyzer/total phosphorus analyzer has a built-in multi-wavelength detector and can measure three parameters: total phosphorus, total nitrogen, and COD (UV).
● Independently designed heating digestion unit, and the integrated design of digestion and measurement within the total phosphorus/total nitrogen analyzer system simplifies piping connections.
● The NPW-160 total nitrogen analyzer/total phosphorus analyzer has a built-in CF card for long-term data storage.
● Equipped with a Chinese touchscreen operation interface for fast and accurate readings, combined with wireless transmission function, intelligent and reliable.
● Low reagent consumption and waste liquid discharge, low operation and maintenance costs, and minimal secondary pollution.
Measuring range: Total nitrogen, 0–2 mg/L to 200 mg/L
Total phosphorus, 0–0.5 mg/L to 20 mg/L
Repeatability: ≤± 3% FS
Analysis interval: 1 hour to 6 hours, freely settable
Sample conditions: Temperature, 2–40°C
Pressure, 0.02–0.05 MPa
Flow rate, 1–3 L/min
Sample volume per analysis approx. 67.5 mL
Reagent replenishment interval: 1 month
Ambient conditions: Temperature, 2–40°C, 85% relative humidity, indoor installation
Analog output: 4–20 mA, load 600 ohm
Relays: Configurable upper/lower limit alarms, fault messages, etc.
Power supply: 220 VAC, 50/60 HZ
Power consumption: 500 VA (max.) 200 VA (average)
Data communication: RS485 serial port
Dimensions: 450 × 380 × 1430 mm
Weight: Approx. 80 Kg
Spare parts
| Spare part Order No. | Instrument model | Chinese description | English description |
|---|---|---|---|
| 103C202 | NPW-160 total phosphorus/total nitrogen analyzer | Lamp module (including light source lamp) | |
| 113D099 | NPW-160 total phosphorus/total nitrogen analyzer | Temperature sensor for heating digestion bath | |
| 115A641 | NPW-160 total phosphorus/total nitrogen analyzer | O-ring | |
| 115A871 | NPW-160 total phosphorus/total nitrogen analyzer | O-ring | |
| 116D005 | NPW-160 total phosphorus/total nitrogen analyzer | Reagent tube 2×3 (Red) | Teflon Tube 2×3 (Red) |
| 116D007 | NPW-160 total phosphorus/total nitrogen analyzer | Reagent tube 2×3 (Orange) | Teflon Tube 2×3 (Orange) |
| 116D302 | NPW-160 total phosphorus/total nitrogen analyzer | PFA tube 2×3 | PFA Tube 2×3 |
| 1.16E+67 | NPW-160 total phosphorus/total nitrogen analyzer | Tube 7×10 | Uni Tube 7×10 |
| 117K041 | NPW-160 total phosphorus/total nitrogen analyzer | Sleeve (Z-union 6 PP.) | Sleeve |
| 131F083 | NPW-160 total phosphorus/total nitrogen analyzer | Printer ribbon cassette | Cassette Ribbon |
| 131H404 | NPW-160 total phosphorus/total nitrogen analyzer | Printer roll paper | Roll Paper |
| 133B493 | NPW-160 total phosphorus/total nitrogen analyzer | Heater for heating digestion bath | |
| 133D156 | NPW-160 total phosphorus/total nitrogen analyzer | Thermostat for heating digestion bath | Thermostat : US-603AXTFL |
| 134C178 | NPW-160 total phosphorus/total nitrogen analyzer | Switching power supply (PS3) | |
| 134C359 | NPW-160 total phosphorus/total nitrogen analyzer | Switching regulator (PS4) | |
| 134C594 | NPW-160 total phosphorus/total nitrogen analyzer | Switching power supply (PS2) | |
| 134G006 | NPW-160 total phosphorus/total nitrogen analyzer | Replacement filter cartridge for G-10 pure water unit | |
| 134G015 | NPW-160 total phosphorus/total nitrogen analyzer | G-10 pure water unit (conductivity meter, with pre/post filters) | |
| 134G3031 | NPW-160 total phosphorus/total nitrogen analyzer | Filter cartridge for built-in pure water unit | |
| 136C025 | NPW-160 total phosphorus/total nitrogen analyzer | Plastic cylinder | |
| 136C135 | NPW-160 total phosphorus/total nitrogen analyzer | Square reagent bottle | |
| 136C136 | NPW-160 total phosphorus/total nitrogen analyzer | Plastic cylinder | |
| 1.36E+108 | NPW-160 total phosphorus/total nitrogen analyzer | Syringe | |
| 5461210K | NPW-160 total phosphorus/total nitrogen analyzer | Syringe pump head assembly | Syringe Pump Head Ass'y |
| 6753031F | NPW-160 total phosphorus/total nitrogen analyzer | CPU board | |
| 6753061F | NPW-160 total phosphorus/total nitrogen analyzer | I/O board (for XH) | |
| 67715000 | NPW-160 total phosphorus/total nitrogen analyzer | Manifold A (Receiver Tank lower part) | |
| 67715100 | NPW-160 total phosphorus/total nitrogen analyzer | Manifold B (Receiver Tank upper part) | |
| 67717300 | NPW-160 total phosphorus/total nitrogen analyzer | Piston | Piston |
| 67745600 | NPW-160 total phosphorus/total nitrogen analyzer | Pure water tank T2 *Pyrex | Reservoir Tank 2 *Pyrex |
| 6775930U | NPW-160 total phosphorus/total nitrogen analyzer | Built-in pure water unit | |
| 6776342K | NPW-160 total phosphorus/total nitrogen analyzer | New type (for XH) | |
| 67776800 | NPW-160 total phosphorus/total nitrogen analyzer | Filter | |
| 67777100 | NPW-160 total phosphorus/total nitrogen analyzer | Manifold C | |
| 67910300 | NPW-160 total phosphorus/total nitrogen analyzer | Reaction vessel, 30 ml *Pyrex | Reaction Vessel, 30ml *Pyrex |
| 6803930K | NPW-160 total phosphorus/total nitrogen analyzer | Sampling tank ASSY | |
| 6804160K | NPW-160 total phosphorus/total nitrogen analyzer | Heater core assembly | Heater Ass'y |
| 6804270K | NPW-160 total phosphorus/total nitrogen analyzer | Reagent pump, 1 unit | |
| 6804350K | NPW-160 total phosphorus/total nitrogen analyzer | 500 mL reagent bottle kit | |
| 6804420S | NPW-160 total phosphorus/total nitrogen analyzer | Syringe assembly (1 set) | |
| 6804470K | NPW-160 total phosphorus/total nitrogen analyzer | Solenoid valve assembly AV-3202 | Solenoid Valve Ass'y AV-3202 |
| 6804490S | NPW-160 total phosphorus/total nitrogen analyzer | Reagent pump motor assembly | Reagent Pump Motor Ass'y |
| 6952210K | NPW-160 total phosphorus/total nitrogen analyzer | Silicone oil (3 g pack) | Greese |
| 6991440F | NPW-160 total phosphorus/total nitrogen analyzer | Terminal board | |
| 7030880F | NPW-160 total phosphorus/total nitrogen analyzer | COD-203 RS232C module (for touchscreen-control unit communication) | |
| 7051510K | NPW-160 total phosphorus/total nitrogen analyzer | Silicone oil (100 g pack) | |
| 7053710F | NPW-160 total phosphorus/total nitrogen analyzer | Driver board | |
| 7101780S | NPW-160 total phosphorus/total nitrogen analyzer | Temperature sensor for reaction vessel | |
| 7135042K | NPW-160 total phosphorus/total nitrogen analyzer | Micro flash memory card (formatted) | |
| 7166041B | NPW-160 total phosphorus/total nitrogen analyzer | 20 mm detector (for China) | |
| 7166051B | NPW-160 total phosphorus/total nitrogen analyzer | 10 mm detector (for China) | |
| 7166061B | NPW-160 total phosphorus/total nitrogen analyzer | 5 mm detector (for China) | |
| 7313240U | NPW-160 total phosphorus/total nitrogen analyzer | Titration pump |
Ordering guide
Standard configuration includes: main unit, operation manual, installation accessories, etc.
NPW160-0-2C11EA000A001
Total phosphorus: 0~0.5 mg/L (factory setting)
Total nitrogen: 0~20 mg/L (factory setting)
20 mm measuring cell, suitable for surface water and tap water as well as compliant municipal wastewater discharge outlets
NPW160-0-2C11GE000A001
Total phosphorus: 0~10 mg/L (factory setting)
Total nitrogen: 0~50 mg/L (factory setting)
10 mm measuring cell, suitable for the wastewater industry
NPW160-0-2C11HF000A001
Total phosphorus: 0~20 mg/L (factory setting)
Total nitrogen: 0~100 mg/L (factory setting)
5 mm measuring cell, suitable for special applications
Source: HACH Water Quality website public information
Recomendados similares
HACHAnalizador de fósforo total / ortofosfato Sigma
HACHAnalizador de sílice en línea
HACHAnalizador automático multiparamétrico de agua
HACHAnalizador de dureza del agua en línea
HACHAnalizador de nitrógeno amoniacal
Analizador COD en línea por método dicromato sc
HACHAnalizador multiparamétrico de agua en línea
HACH