产品概述
The next standard in the evolution of turbidity
Compliant with EPA approved Hach Method 10258 and perfect for membrane filtration applications, the TU5400sc employs a patented optical design that sees more of your sample than any other turbidimeter, delivering the best low level precision and sensitivity while minimizing variability between measurements. For the first time you will be able to remove uncertainty of which measurement to trust between your lab and process instruments, thanks to identical 360° x 90° Detection® Technology in any TU5 Series® turbidimeter. The TU5400sc Ultra-High Precision Low Range Laser Turbidimeter dramatically reduces the time needed to get a turbidity measurement you can rely on. With a 10mL sample size, response time is over 15 times faster than an FT660. A stable laser light source eliminates the need for annual lamp replacements. The turbidimeter’s measurement surface area has been reduced by 98%, allowing you to save time cleaning. With a mounting pattern identical to the FT660, replacing your previous turbidimeter is fast and simple. All of this, along with the ability to measure to 0.0002 NTU, gives you the next standard in the evolution of turbidity. A flow meter is included with this turbidimeter that continuously measures flow through the instrument and displays the flow value on screen. Current flow can be output to SCADA via 4-20mA or digital communications. Ensure that your turbidimeter is always functioning properly with this TU5's System Check capability. With the ability to provide information on measurement status and vial cleanliness, you can have full confidence in your turbidity measurement. RFID technology included with this turbidimeter delivers easy calibration and simple, paperless turbidity measurement comparisons between your process turbidimeter and the TU5200.
主要特点
- Groundbreaking 360° x 90° Detection™ Technology:The TU5 Series employs a patented optical design that sees more of your sample than any other turbidimeter, delivering the best low level precision and sensitivity while minimizing variability from test to test.
- Everything about turbidity – faster:The TU5 Series dramatically reduces the time needed to get a turbidity measurement you can rely on, with 98% less online sample surface area to clean, sealed vials for calibration, and the elimination of the need for indexing and silicone oil in the lab. Not to mention, a smaller online sample volume means you will detect events almost immediately.
- Easy Adoption:The familiar experience of a modern touchscreen, the ability to use your current Hach sensors, and the same footprint as the SC200, make installation and integration of the SC4500 Controller seamless.
- No Time for Downtime:The SC4500's built-in predictive diagnostic software ensures measurement confidence and reduces the risk of unexpected equipment downtime by enabling proactive maintenance planning via MSM, including step-by-step instructions.
技术参数
| 参数名称 | 说明 |
|---|---|
| Accuracy | ±2% or 0.01 NTU from 0 - 40 NTU ±10% of reading from 40 - 1000 NTU based on Formazin primary standard |
| Cable Length | 1.6 m (5.25 ft), extendable up to 50 m (164 ft) for instrument without accessories |
| Calibration Method | For Formazin and Stablcal®: 20 NTU from 0 to 40 NTU; at 20 FNU and 600 NTU for full range Custom calibration for up to 6-point calibrations |
| Certifications | CE compliant US FDA accession number: 1420493-000 EPA version, 1420492-000 ISO version Australian ACMA Marking |
| Communication | System Check & RFID |
| Controller | 2 Channels, 100-240 VAC |
| Dimensions (H x W x D) | 249 mm x 268 mm x 190 mm |
| Enclosure Rating | Electronic compartment IP55; all other functional units IP65 with process head/ACM attached to the TU5300sc/TU5400sc instrument |
| Fitting Type | Sample quick connector: ¼-in. for ¼-in. tubing |
| Instrument | With Flow Sensor |
| Light Source | Class 2 laser product, with embedded 650 nm (EPA 0.43 mW) or Class 1 laser product, with embedded 850 nm (ISO), max. 0.55 mW (complies with IEC/EN 60825-1 and to 21 CFR 1040.10 in accordance with Laser Notice No. 50) |
| Material | ASA Luran S 777K / RAL7000, TPE RESIN Elastocon® STK40, Thermoplastic Elastomer TPS-SEBS |
| Model | TU5400sc |
| Mounting Configurations | Wall Mount |
| Operating Humidity | Relative humidity: 5 - 95% at different temperatures, non-condensing |
| Operating Temperature Range | 0 - 50 °C (32 - 122 °F) |
| Options | Process Head & Flow Sensor |
| Range | EPA: 0 - 700 NTU / FNU / TE/F / FTU 0 - 100 mg/L 0 - 175 EBC ISO: 0 - 1000 NTU / FNU / TE/F / FTU 0 - 100 mg/L 0 - 250 EBC |
| Regulatory | EPA |
| Repeatability | Better than 1% of reading or ±0.002 NTU (TU5300sc) or ±0.0006 NTU (TU5400sc) on Formazin at 25 °C (77 °F), whichever is greater |
| Resolution | 0.0001 NTU / FNU / TE/F / FTU / EBC |
| Response Time | TU5300sc: T90 <45 seconds at 100 mL/min TU5400sc: T90 <30 seconds at 100 mL/min |
| Sample Flow Rate | 100 - 1000 mL/min; optimal flow rate: 200 - 500 mL/min |
| Sample Pressure | 6 bar (87 psi) maximum, compared to air at sample temperature range from 2 - 40 °C (35.6 - 104 °F) |
| Sample Temperature | 2 - 60 °C (35 - 140 °F) |
| Signal Average Time | TU5300sc: 30 - 90 seconds TU5400sc: 1 - 90 seconds |
| Storage Conditions | -40 - 60 °C (-40 - 140 °F) |
| Stray Light | <10 mNTU |
| Units | NTU, FNU, TE/F, FTU, EBC |
| Verification | Liquid: Stablcal®, Formazin (0.1 - 40 NTU) Dry: Glass Rod at <0.1 NTU |
| Weight | 5.95 lbs. (2.7 kg); 11 lbs. (5.0 kg) with all accessories |
| What's included? | Controller, Non-Claros + Embedded Prognosys, without power cord; includes mounting hardware |
应用领域
Filtration · Membrane Protection · Regulations · Water Reuse
同系列其他配置
| 型号 | |
|---|---|
| LXV525.97KTO039 | TU5400sc Ultra-High Precision Low Range Laser Turbidimeter, EPA, Auto |
资料下载
- Care Advantage Flyer : Complete service solution for all your instruments
- Care Advantage Brochure : Complete service solution for all your instruments
- Stablcal Turbidity Standards for TU5 Series Turbidimeters
- Bộ đo độ đục dòng TU5
- Installation Manual : SC4500 Controller
- Basic User Manual : SC4500 Controller
- Basic User Manual : SC4500 Controller
- Instruction Sheet: 2FF SIM Card for SC4500 and SC1500 - MSM (8796100)
Casos de servicio
Tratamiento de Aguas Residuales Municipales — Controladores y sensores: caso de aplicación
Situación en planta
Se trata de un cliente del sector Tratamiento de Aguas Residuales Municipales cuya planta está en las etapas de entrada, biológica y salida de una planta municipal. La tarea principal era monitorización en línea con combinación de controlador y sensores.
El problema
La dificultad está en alto contenido de sólidos y componentes corrosivos, con grandes variaciones diarias de caudal; a la vez, los parámetros del efluente oscilan y las sondas se ensucian con lodos y biopelícula. Por eso la especificación implica emparejar cada canal del controlador con su tipo de sensor.
Qué hicimos
Adoptamos un enfoque de Hach: suministrar según referencias originales de Hach. La entrega se construyó en torno a emparejar cada canal del controlador con su tipo de sensor; se verificó punto por punto: cumplimiento estable del nivel 1A y reporte de datos en línea.
Resultado operativo
En servicio el sistema responde a lo previsto: combinaciones de fábrica que facilitan localizar fallos, con un mantenimiento rutinario notablemente menor.
Alimentación y Bebidas — Controladores y sensores: caso de aplicación
Contexto de aplicación
las etapas de dosificación, pasteurización, llenado y limpieza CIP es un servicio típico de Alimentación y Bebidas. El proyecto partió de Controladores y sensores, centrándose en monitorización en línea con combinación de controlador y sensores.
Limitaciones del proceso
las limpiezas frecuentes exigen instrumentos resistentes a ciclos CIP/SIP con sosa caliente, y jarabes, lácteos y bebidas proclives a incrustaciones, con estrictos requisitos higiénicos no hace sino acentuarlo. Por eso la especificación de Controladores y sensores debe cubrir emparejar cada canal del controlador con su tipo de sensor.
Enfoque de suministro
La entrega se gestionó como Hach: suministrar según referencias originales de Hach. La ejecución se centró en emparejar cada canal del controlador con su tipo de sensor, junto con requisitos de seguridad alimentaria y diseño higiénico 3-A / EHEDG.
Resultados en campo
La operación evidencia el beneficio: combinaciones de fábrica que facilitan localizar fallos, con una confianza claramente mayor en este punto de medición.
Química y Farmacéutica — Controladores y sensores: caso de aplicación
Perfil del cliente
El entorno típico en Química y Farmacéutica es reactores, vasijas de dosificación y tanques de producto terminado. El punto de medición es Controladores y sensores; el foco es monitorización en línea con combinación de controlador y sensores.
Dificultades clave
Las condiciones son medios muy corrosivos con disolventes y cristalización, en parte en atmósferas explosivas y, encima, la corrosión y la protección Ex acortan la vida útil y encarecen las paradas, algo que una configuración estándar no soporta mucho tiempo. El diseño parte de emparejar cada canal del controlador con su tipo de sensor.
Implementación
El alcance se canalizó por la vía de Hach: suministrar según referencias originales de Hach. Técnicamente se apoya en emparejar cada canal del controlador con su tipo de sensor, y en estos requisitos: certificación Ex y trazabilidad de datos según GMP.
Beneficio para el cliente
En la práctica esto significa combinaciones de fábrica que facilitan localizar fallos, lo que redujo la carga del equipo de mantenimiento.
Energía y Electricidad — Controladores y sensores: caso de aplicación
Antecedentes del proyecto
El proyecto abarca agua de alimentación, condensado de turbina y sistemas de desulfuración/DeNOx. El trabajo se centra en Controladores y sensores y la tarea principal es monitorización en línea con combinación de controlador y sensores.
Condiciones de servicio
El medio y el servicio se caracterizan por alta temperatura y presión, con vapor y agua salina, y además deriva a alta temperatura y presión, con paradas no programadas muy costosas. Por eso Controladores y sensores no puede especificarse de forma genérica: requiere emparejar cada canal del controlador con su tipo de sensor.
Solución
El equipo técnico de Ainstru trabajó por la vía de Hach: suministrar según referencias originales de Hach. La configuración incluye emparejar cada canal del controlador con su tipo de sensor; se cuidaron estos requisitos: cumplimiento de normativas del sector y objetivos de disponibilidad.
Resultados
Desde la puesta en marcha el sistema funciona de forma estable; el resultado práctico es combinaciones de fábrica que facilitan localizar fallos.