Order Code:5W5B1H-AAHIBAEAAFAAABAQD320AA1+AB
Name:Promag W 500, 5W5B1H, DN100 4"
Configuration
| Code | Name | Order | Specification |
|---|---|---|---|
| 010 | Approval; Transmitter; Sensor | AA | Non-hazardous area |
| 011 | Design | H | Lap joint flange, 0 x DN inlet/ outlet runs |
| 015 | Power Supply | I | AC 100...240V/DC 24V |
| 020 | Output; Input 1 | BA | 4-20mA HART |
| 021 | Output; Input 2 | E | Pulse/freq./switch output |
| 022 | Output; Input 3 | A | W/o; |
| 023 | Output; Input 4 | A | W/o; |
| 030 | Display; Operation | F | 4-line illum.; touch control |
| 035 | Integrated ISEM Electronic | A | Sensor |
| 041 | Transmitter Housing | A | Alu, coated |
| 042 | Sensor Junction Housing | A | Alu, coated |
| 045 | Cable, Sensor Connection | B | 20m/60ft digital |
| 050 | Electrical Connection | A | Gland M20 |
| 060 | Liner | Q | PTFE 90oC |
| 070 | Process Connection | D32 | PN16, carbon steel, lap joint flange EN1092-1 |
| 075 | Electrodes | 0 | 1.4435/316L |
| 080 | Flow Calibration | A | 0.5% |
| 480 | Device Model | A1 | 1 |
| 500 | Operation Language Display | AB | German |
Configuration Explained
This is a 5W4C electromagnetic flowmeter, non-hazardous area, loose flange design with no straight pipe requirement upstream or downstream for a flexible installation position, 100-230V AC or 24V DC supply, 4-20mA HART plus pulse, frequency and switch, four-line backlit display with touch keys, remote transmitter with 20m digital cable, PTFE liner rated to 90 °C, PN16 carbon steel loose flange, 316L electrodes, suitable for flow metering in large-diameter wastewater pipes.