Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

5W8C/5W8B Battery-powered electromagnetic flowmeter

5W8C/5W8B Battery-powered electromagnetic flowmeter
Battery-powered electromagnetic flowmeter
Endress+Hauser 5W8C/5W8B
Promag W 800 is ideal for off-grid applications in the water industry, even flow measurement in direct underground installation or underwater. Promag 800 covers basic functionality, Promag 800 Advanced offers the full performance spectrum. The battery-powered transmitter provides worldwide transmission of measured data without additional energy supply. Heartbeat Technology ensures measurement reliability and compliant verification.

Promag W is a specialist sensor for all applications in the water industry. In regions without a backbone power grid, Promag W 800 combined with the battery-powered Proline 800 transmitter is used for water and wastewater measurement and is the preferred solution for all applications in this industry. Promag L 800 also provides worldwide transmission of measurement data and events via e-mail and SMS.

Advantages
Suitable for direct burial or long-term underwater use - certified sensor
Safe and reliable long-term operation - fully welded sensor, robust and durable
Energy-efficient flow measurement - cross-section identical to the pipe, no pressure loss
Maintenance-free - no moving parts
No backbone grid required - battery life up to 15 years
Worldwide transmission of measurement data and events via e-mail and SMS - integrated GSM/GPS modem
Reliable data storage - integrated SD card

Application
The bidirectional measuring principle is not limited by pressure, density, temperature or viscosity
Certified sensor for the most demanding water and wastewater applications
Device characteristics
International drinking water approvals
Protection rating IP68 (6P housing)
Transmitter housing in durable polycarbonate
Battery and wireless modem all housed in the same enclosure
Measuring cycle can be adjusted individually

 

Spare Parts & Accessories 45

45 spare parts · click to collapse
Order codeDescription
XPD0055-Electronic module, Advanced Input/Output Option I, 800(C)Usage: Promag 800(C), (C) = generation index C, Adv. = Functionality: Transmitter Advanced. Consists of: Main electronic (amplifier and I/O), Display.Enquire
XPD0056-Electronic module, Advanced I/O option M, 800(C)Usage: Promag 800(C), (C) = generation index C, Adv. = Functionality: Transmitter Advanced. Consists of: Main electronic (amplifier and I/O), Display.Enquire
XPD0057-Electronic plug-in module, Advanced input/output option P, 800(C)Usage: Promag 800(C), (C) = generation index C, Adv. = Functionality: Transmitter Advanced. Consists of: Main electronic (amplifier and I/O), Display, Cellular radio module.Enquire
71484378Power supply kit, AC 100...240 V / DC 19...30 VUsage: Promag 800(C), (C) = generation index C, transmitter housing.Details
71484379External power supply connection board kitUsage: Promag 800(C), (C) = generation index C, transmitter housing.Details
XPD0058-Electronic, Std., I/O option K, 800(C)Usage: Promag 800(C), (C) = generation index C, Std. = Functionality: Standard transmitter. Consists of: Main electronics (amplifier and I/O), Display. Usage: Promag 800(C), (C) = generation index C, Std. = Functionality: Standard transmitter. Consists of: Main electronics (amplifier and I/O), Display.Enquire
XPD0059-Electronic, Std., I/O option N, 800(C)Usage: Promag 800(C), (C) = generation index C, Std. = Functionality: Standard transmitter. Consists of: Main electronics (amplifier and I/O), Display. Usage: Promag 800(C), (C) = generation index C, Std. = Functionality: Standard transmitter. Consists of: Main electronics (amplifier and I/O), Display.Enquire
71484380Kit connection board I/O-modules, 800(C)Usage: Promag 800(C), (C) = generation index C, transmitter housing.Details
71484382Kit S+T-DAT, compact, Promag 800(C)Electronic storage module unprogrammed Usage: Promag 800(C), (C) = generation index C. Consists of: S+T-DAT.Details
71484383Connection board kit + S+T-DAT, remoteElectronic storage module unprogrammed Usage: Promag 800(C), (C) = generation index C. transmitter housing. Consists of: S+T-DAT.Details
71484384Circuit + battery carrier kit, 800(C)Usage: Promag 800(C), (C) = generation index C, transmitter housing. Consists of: circuit carrier electronic, support with hinge, cover to power output, cover to circuit carrier electronic.Details
71484385Kit electronic-ribbon cable, 800(C)Usage: Promag 800(C), (C) = generation index C, transmitter housing.Details
71484386Power supply terminal kitUsage: Promag 800(C), (C) = generation index C, transmitter housing. Consists of: 1x connecting terminal pluggable 3-Pol., 2x connecting terminal pluggable 4-Pol.Details
71484387Terminal kit, external power supplyUsage: Promag 800(C), (C) = generation index C, transmitter housing. Consists of: 2x connecting terminal pluggable 4-Pol.Details
71496693Kit antenna complete, Promag 800(C)Usage: Promag 800(C), (C) = generation index C, transmitter housing. Consists of: antenna, connection cable in the transmitter, assembly material.Details
71488161Kit conn. board, remote, sensor WUsage: Promag 800(C), (C) = generation index C, Sensor connection housing. Consists of: connection board.Details
71615503terminal boardUsage: Promag 400(C) sensor L/W non-haz, Promag 800(C) sensor W non-haz. (C) = generation index C, Sensor connection housing. Consists of: connection board.Details
71408508housing coverUsage: Promag/Prosonic Flow 400, Promag/Promass/Prosonic Flow/t-mass/ Teqwave MW 500 digital, Promag 800(C), (C) = generation index C, transmitter housing polycarbonate. Consists of: cover polycarbonate complete, O-Ring 196,44x3,53 VMQ, default and -50oC/-58oF, wire with screw lock 1,5x150.Details
71278077Polycarbonate cover gasketUsage: Prosonic Flow 400, Promag/Promass/Prosonic Flow/t-mass/ Teqwave MW 500 digital, Promag 400/800(C), (C) = generation index C, transmitter housing polycarbonate. Consists of: 10x O-Ring 196,44x3,53 VMQ.Details
71228796Cover assemblyUsage: Promag 10/500, Promass 500, Promag/Promass/Prosonic Flow/t-mass/ Teqwave MW 500 digital, Promag 400/800(C), (C) = generation index C, sensor connection housing. Consists of: cover Alu, O-Ring 113,90x3,53 HNBR.Details

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

 

 

Source:Endress+Hauserwebsite public information

Measuring principle video

Click to play
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Electromagnetic flow meter — Application Case

Site Conditions

This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was volumetric flow of conductive liquids.

The Problem

The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means choosing liner and electrode pairing by conductivity, solids and abrasion.

What We Did

We took a flow range approach — flow solution matched to line size, medium and range. Delivery was built around choosing liner and electrode pairing by conductivity, solids and abrasion, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.

Operating Outcome

In service the system performs as intended — no obstruction, so pressure loss is minimal and upkeep low, with routine maintenance falling noticeably.

Food & Beverage

Food & Beverage · Electromagnetic flow meter — Application Case

Application Context

dosing, pasteurising, filling and CIP stages is a typical Food & Beverage duty. The project started from Electromagnetic flow meter, focusing on volumetric flow of conductive liquids.

Process Constraints

frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, and syrups, dairy and beverages that scale easily, under strict hygienic requirements only amplify it. The Electromagnetic flow meter specification must therefore cover choosing liner and electrode pairing by conductivity, solids and abrasion.

Delivery Approach

Delivery was handled as the flow range — flow solution matched to line size, medium and range. Execution centred on choosing liner and electrode pairing by conductivity, solids and abrasion, together with food-safety and hygienic design per 3-A / EHEDG.

Field Results

Operation shows the benefit clearly — no obstruction, so pressure loss is minimal and upkeep low, with confidence in this measuring point improving markedly.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Electromagnetic flow meter — Application Case

Customer Profile

The typical setting in Chemical & Pharmaceutical is reactors, metering vessels and finished-product tanks. The measuring point is Electromagnetic flow meter; the focus is volumetric flow of conductive liquids.

Key Difficulties

Conditions are highly corrosive media with solvents and crystallisation, partly in explosive atmospheres and, on top of that, corrosion plus Ex protection shortens instrument life and makes downtime costly, which a standard configuration cannot handle for long. The design therefore starts with choosing liner and electrode pairing by conductivity, solids and abrasion.

Implementation

The scope ran through the flow range: flow solution matched to line size, medium and range. Technically it hinges on choosing liner and electrode pairing by conductivity, solids and abrasion, and on these requirements: Ex certification and GMP traceability of records.

Customer Benefit

In practice this means no obstruction, so pressure loss is minimal and upkeep low, which cut the workload on the site maintenance team.

Power & Energy

Power & Energy · Electromagnetic flow meter — Application Case

Project Background

The project covers boiler feedwater, turbine condensate and FGD/DeNOx systems. The work centres on Electromagnetic flow meter and the core task is volumetric flow of conductive liquids.

Operating Challenges

The medium and duty are characterised by high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. So Electromagnetic flow meter cannot be specified generically — it calls for choosing liner and electrode pairing by conductivity, solids and abrasion.

Solution

The Ainstru engineering team worked through the flow range: flow solution matched to line size, medium and range. The configuration involves choosing liner and electrode pairing by conductivity, solids and abrasion, with these requirements in view: compliance with power-industry codes and unit availability targets.

Results

Since start-up the system has run steadily; the practical result is no obstruction, so pressure loss is minimal and upkeep low.