Vortex flowmeter
Prowirl F 200, 7F2B50, DN50 2";Approval NEPSI Ex ia IIC Zone 0/1 DIP A21;Output/Input 4-20mA HART;Display/Operation SD02 4-line; push buttons + data backup function;Housing GT20 dual compartment, alu,
Order Code:7F2B50-N4ACCD1D2SK+AK
Name:Prowirl F 200, 7F2B50, DN50 2"
Configuration
| Code | Name | Order | Specification |
|---|---|---|---|
| 010 | Approval | N4 | NEPSI Ex ia IIC Zone 0/1 DIP A21 |
| 020 | Output; Input | A | 4-20mA HART |
| 030 | Display; Operation | C | SD02 4-line; push buttons + data backup function |
| 040 | Housing | C | GT20 dual compartment, alu, coated |
| 050 | Electrical connection | D | Thread NPT1/2 |
| 060 | Sensor Version | 1 | Volume flow basic, 316L, -40...+260oC/-40...+500oF |
| 070 | Process Connection | D2S | PN40, flange EN1092-1-B1 |
| 080 | Calibration Flow | K | 0.75% volume 3-point |
| 500 | Operation Language Display | AK | Chinese simplified |
Configuration Explained
This is a 7F2B50 vortex flowmeter, multi-function type, with wet steam detection, measures volumetric flow, with NEPSI intrinsically safe approval for Zone 0 and Zone 1, with 4-20mA HART output, four-line LCD display with data backup, aluminium dual chamber housing, PN40 European standard B1 flange, 316L sensor withstands -40 to 260 °C, 0.75% three-point calibration, Chinese interface, suitable for steam metering.
Related Products
Endress+HauserVortex flowmeter
View →
Endress+HauserVortex flowmeter
View →
Endress+HauserVortex flowmeter
View →
Endress+HauserVortex flowmeter
View →
Endress+HauserVortex flowmeter
View →
Endress+HauserVortex flowmeter
View →
Endress+HauserVortex flowmeter
View →
Endress+HauserVortex flowmeter
View →