Technical Data
CompareDisinfection
| Measuring Principle | |
| Application | Drinking water Utilities of all industries For low sample flow |
| Characteristic | Flow through assembly for one disinfection sensor |
| Design | Flow assembly with direct inflow to the membran |
| Material | Plexiglas (PMMA) |
| Dimension | 85 mm x 85 mm x 220 mm (3.35 inch x 3.35 inch x 8.64 inch) |
| Process temperature | Max. 60 °C (Max. 140 °F) |
| Process pressure | Max. 4 bar relative (Max. 58 psi relative) |
The Flowfit CCA151 assembly is used to install disinfectant sensors that do not require pH compensation, such as chlorine dioxide sensors, and is easy to use. The sensor is installed in an acrylic glass rod, allowing high-precision measurement as long as the medium flow rate is at least 5 l/h (1.32 gph). Precise control of the disinfection process therefore requires only minimal water loss. The Flowfit CCA151 offers flexible installation with panel, wall and pipe mounting options, allowing the disinfectant sensor to be installed at the most suitable location for optimal measurement results.
Benefits
-
Minimum water loss: when the sensor is installed in the Flowfit CCA151, high-precision chlorine dioxide measurement is possible as long as the medium flow rate is at least 5 l/h (1.32 gph). Only a very small amount of water is consumed.
-
Reliable measurement: flexible installation allows the sensor to be positioned precisely where the chlorine dioxide concentration needs to be accurately determined.
-
Cost-effective upgrade of your measuring point: identical external dimensions to the CCA250, making replacement simple.
Applications
-
The CCA151 flow assembly has no pH compensation function and is used to install disinfectant sensors, e.g. chlorine dioxide sensors, and is suitable for:
-
Drinking water
-
Utilities in various industries
-
Low-flow applications
Spare Parts & Accessories 3
3 spare parts · click to collapse
| Order code | Description | |
|---|---|---|
| 71372020 | CCA151 spare part: blind headContent: Locking screw, blind plug with O-ring | Details |
| 71372109 | CCA151 wall mounting fastener | Details |
| 71372027 | CCA151 adapter kit CCS5x + CCS5xD, incl.: retaining ring, thrust ring, sealing ringContent: Clamp ring, thrust ring, + sealing | Details |
Configurator / Comparison
Source: Endress+Hauserpublic information from the website
Manuals & Documents 2
All documents for this modelCase Studies
Municipal Wastewater Treatment · sterilize — Application Case
Customer Profile
The typical setting in Municipal Wastewater Treatment is the inlet, biological and outlet stages of a municipal plant. The measuring point is sterilize; the focus is monitoring and controlling disinfectant dosing and efficacy.
Key Difficulties
Conditions are high solids and corrosive fractions, with large diurnal flow swings and, on top of that, effluent parameters drift and probes foul with sludge and biofilm, which a standard configuration cannot handle for long. The design therefore starts with matching monitoring points to the disinfection route (chlorine, UV, ozone).
Implementation
The scope ran through the analyser range: selecting as part of a complete water-analysis system. Technically it hinges on matching monitoring points to the disinfection route (chlorine, UV, ozone), and on these requirements: stable compliance with Grade 1A discharge limits and online data reporting.
Customer Benefit
In practice this means on-demand dosing, lowering both by-products and cost, which cut the workload on the site maintenance team.
Food & Beverage · sterilize — Application Case
Project Background
The project covers dosing, pasteurising, filling and CIP stages. The work centres on sterilize and the core task is monitoring and controlling disinfectant dosing and efficacy.
Operating Challenges
The medium and duty are characterised by syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. So sterilize cannot be specified generically — it calls for matching monitoring points to the disinfection route (chlorine, UV, ozone).
Solution
The Ainstru engineering team worked through the analyser range: selecting as part of a complete water-analysis system. The configuration involves matching monitoring points to the disinfection route (chlorine, UV, ozone), with these requirements in view: food-safety and hygienic design per 3-A / EHEDG.
Results
Since start-up the system has run steadily; the practical result is on-demand dosing, lowering both by-products and cost.
Chemical & Pharmaceutical · sterilize — Application Case
Project Overview
The site is reactors, metering vessels and finished-product tanks. The customer wanted sterilize properly configured on the existing plant, with the aim of monitoring and controlling disinfectant dosing and efficacy.
Technical Challenges
What actually causes trouble is highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. All of this means the sterilize configuration has to involve matching monitoring points to the disinfection route (chlorine, UV, ozone).
Configuration
Supply and installation were organised through the analyser range: selecting as part of a complete water-analysis system. On site this meant matching monitoring points to the disinfection route (chlorine, UV, ozone), checked line by line against: Ex certification and GMP traceability of records.
Performance
After commissioning the outcome is on-demand dosing, lowering both by-products and cost, and the readings are now used for process tuning.
Power & Energy · sterilize — Application Case
Site Conditions
This is a Power & Energy customer whose plant is at boiler feedwater, turbine condensate and FGD/DeNOx systems. The main task was monitoring and controlling disinfectant dosing and efficacy.
The Problem
The difficulty lies in high temperature and pressure with both steam and saline water; at the same time drift under high temperature and pressure, with very costly unplanned outages. Specification therefore means matching monitoring points to the disinfection route (chlorine, UV, ozone).
What We Did
We took a analyser range approach — selecting as part of a complete water-analysis system. Delivery was built around matching monitoring points to the disinfection route (chlorine, UV, ozone), with point-by-point checks on: compliance with power-industry codes and unit availability targets.
Operating Outcome
In service the system performs as intended — on-demand dosing, lowering both by-products and cost, with routine maintenance falling noticeably.