Instrumentation · Engineering · Package · PLC
0755-8222 1901 sales@ainstru.com

CCS55D Free Bromine Sensor

CCS55D Free Bromine Sensor

游离溴传感器

Memosens digital sensors for measuring seawater and process water
Compare

Disinfection

Measuring Principle
Application Seawater - to ensure reliable disinfection
Process water - wide range of application due to large measuring range
Pool water - efficient dosing thanks to precise measurement
Characteristic Amperometric measurement of dissolved free bromine
Measuring range Trace: 0 ... 5 mg/l HOBr
Standard: 0 ... 20 mg/l HOBr
High: 0 ... 200 mg/l HOBr
Measuring principle Closed, membrane covered measuring cell
Reduction of free bromine at the working electrode
Design Closed amperometric 2-electrode measuring cell with PET membrane
Material Sensor shaft: POM
Membrane: PET
Membrane cap: PVDF
Dimension Diameter: 25 mm (0.98 in)
Length: 161 mm (6.34 in)
Process temperature +0...55 °C (32 ... 130°F), non-freezing
Process pressure Max. 1 bar (max. 14.5 psi)
Temperature sensor 10k NTC integrated (Memosens)
Connection Inductive, digital connection head with Memosens technology

The Memosens CCS55D is a low-maintenance digital free bromine sensor. It measures reliably in seawater desalination plants, process water, cooling water, swimming pools and fish farms, delivering stable measured values. The free bromine sensor safely disinfects even with small amounts of water. Its fast response ensures efficient process control. The CCS55D uses Memosens digital technology for maximum process and data integrity, and it is simple to operate.

Advantages
Different sensor versions for different applications: from trace measurement up to a free bromine concentration of no more than 200 mg/l.
Fast response (t90 < 20 seconds) with high-precision indication of the process status, enabling prompt action in response to process changes and efficient process control. It remains active in bromine-free media and measures as soon as bromine appears.
Greater process safety: precise measurement with high long-term stability enables permanent process monitoring and flexible, on-demand adjustment of the disinfectant dosage.
Safe seawater disinfection, because adding chlorine to seawater forms bromine compounds. Monitoring the chlorine concentration would cause measurement errors and poor disinfection results.
Fast, convenient sensor replacement and longer trouble-free operating time: the sensor can be precalibrated in the laboratory and is ready for plug-and-play in the field.
Combined with the Liquiline multiparameter transmitter, it can simultaneously measure other relevant water analysis parameters, such as pH and ORP.

Application areas
The Memosens CCS55D free bromine sensor is suitable for all kinds of water quality:
Seawater applications, e.g. seawater desalination plants, ensuring reliable disinfection and avoiding overdosing
Food industry, high-precision control of fish farm water
Process water and cooling water, using bromine disinfectants to reduce corrosion
Swimming pool water and bathing water, using bromine instead of chlorine as the disinfectant due to water salinity

 

E+H Product Model Configurator

Please enter the product model to configure

Product comparison

Please enter the product models to compare in the input fields below; up to three products can be compared

 

   

Technical documentation

   

Technical data

 

 

Documents / Manuals / Software

 

 

Accessories / Spare parts

 

A

Source:Endress+Hauserpublic information from the website

Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · Disinfection Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Disinfection.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Disinfection for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · Disinfection Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Disinfection.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Disinfection for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · Disinfection Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Disinfection.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Disinfection for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · Disinfection Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Disinfection.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Disinfection for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.