CCS55D Free Bromine Sensor

CCS55D Free Bromine Sensor
Free bromine sensor
Memosens digital sensors for measuring seawater and process water
Compare

Disinfection

Measuring Principle
Application Seawater - to ensure reliable disinfection
Process water - wide range of application due to large measuring range
Pool water - efficient dosing thanks to precise measurement
Characteristic Amperometric measurement of dissolved free bromine
Measuring range Trace: 0 ... 5 mg/l HOBr
Standard: 0 ... 20 mg/l HOBr
High: 0 ... 200 mg/l HOBr
Measuring principle Closed, membrane covered measuring cell
Reduction of free bromine at the working electrode
Design Closed amperometric 2-electrode measuring cell with PET membrane
Material Sensor shaft: POM
Membrane: PET
Membrane cap: PVDF
Dimension Diameter: 25 mm (0.98 in)
Length: 161 mm (6.34 in)
Process temperature +0...55 °C (32 ... 130°F), non-freezing
Process pressure Max. 1 bar (max. 14.5 psi)
Temperature sensor 10k NTC integrated (Memosens)
Connection Inductive, digital connection head with Memosens technology

The Memosens CCS55D is a low-maintenance digital free bromine sensor. It measures reliably in seawater desalination plants, process water, cooling water, swimming pools and fish farms, delivering stable measured values. The free bromine sensor safely disinfects even with small amounts of water. Its fast response ensures efficient process control. The CCS55D uses Memosens digital technology for maximum process and data integrity, and it is simple to operate.

Advantages

  • Different sensor versions for different applications: from trace measurement up to a free bromine concentration of no more than 200 mg/l.

  • Fast response (t90 < 20 seconds) with high-precision indication of the process status, enabling prompt action in response to process changes and efficient process control. It remains active in bromine-free media and measures as soon as bromine appears.

  • Greater process safety: precise measurement with high long-term stability enables permanent process monitoring and flexible, on-demand adjustment of the disinfectant dosage.

  • Safe seawater disinfection, because adding chlorine to seawater forms bromine compounds. Monitoring the chlorine concentration would cause measurement errors and poor disinfection results.

  • Fast, convenient sensor replacement and longer trouble-free operating time: the sensor can be precalibrated in the laboratory and is ready for plug-and-play in the field.

  • Combined with the Liquiline multiparameter transmitter, it can simultaneously measure other relevant water analysis parameters, such as pH and ORP.

Application areas

  • The Memosens CCS55D free bromine sensor is suitable for all kinds of water quality:

  • Seawater applications, e.g. seawater desalination plants, ensuring reliable disinfection and avoiding overdosing

  • Food industry, high-precision control of fish farm water

  • Process water and cooling water, using bromine disinfectants to reduce corrosion

  • Swimming pool water and bathing water, using bromine instead of chlorine as the disinfectant due to water salinity

Spare Parts & Accessories 7

7 spare parts · click to collapse
Order codeDescription
CCV05-Maintenance Kit CCV05Memosens CCSxxD/fixed cable sensor CCSxxEnquire
71372025CCA250 adapter kit CCS5x + CCS5xDDetails
71372026CYA112 adapter kit CCS5x + CCS5xDDetails
71372027CCA151 adapter kit CCS5x + CCS5xD, incl.: retaining ring, thrust ring, sealing ringContent: Clamp ring, thrust ring, + sealingDetails
71554885Adapter kit CCS5x(D/E) for CYA27-xxxB*Details
COY8-Zero-Point Gel COY8Zero point: Verification, calibration, adjustment at zero point of oxygen and disinfection sensors ::Amperometric and optical sensors ::12, 25 and 40mm diameter ::Application in the lab, in the fieldEnquire
71257946Handheld DPD Colorimetric Calibrator PF-3colorimetric measurement of free and total chlorine 0,05 - 6mg/l Disinfection, drinking and process water hand held photometer, IP67-graded, with cuvettes, DPD, according to ISO 7393 delivery in plastic case, test kit for free and total chlorine included hand-held photometer for calibration and verification of disinfection loopsDetails

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

Accessories / Spare parts

Source:Endress+Hauserpublic information from the website

All documents for this model
3 documents · click to expand
BA

Memosens CCS55D English

Rev. 0220 56 pages
Preview
TI

Memosens CCS55D Chinese

Rev. 0119 16 pages
Preview
TI

Memosens CCS55D English

Rev. 0119 16 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · sterilize — Application Case

Customer Profile

The typical setting in Municipal Wastewater Treatment is the inlet, biological and outlet stages of a municipal plant. The measuring point is sterilize; the focus is monitoring and controlling disinfectant dosing and efficacy.

Key Difficulties

Conditions are high solids and corrosive fractions, with large diurnal flow swings and, on top of that, effluent parameters drift and probes foul with sludge and biofilm, which a standard configuration cannot handle for long. The design therefore starts with matching monitoring points to the disinfection route (chlorine, UV, ozone).

Implementation

The scope ran through the analyser range: selecting as part of a complete water-analysis system. Technically it hinges on matching monitoring points to the disinfection route (chlorine, UV, ozone), and on these requirements: stable compliance with Grade 1A discharge limits and online data reporting.

Customer Benefit

In practice this means on-demand dosing, lowering both by-products and cost, which cut the workload on the site maintenance team.

Food & Beverage

Food & Beverage · sterilize — Application Case

Project Background

The project covers dosing, pasteurising, filling and CIP stages. The work centres on sterilize and the core task is monitoring and controlling disinfectant dosing and efficacy.

Operating Challenges

The medium and duty are characterised by syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. So sterilize cannot be specified generically — it calls for matching monitoring points to the disinfection route (chlorine, UV, ozone).

Solution

The Ainstru engineering team worked through the analyser range: selecting as part of a complete water-analysis system. The configuration involves matching monitoring points to the disinfection route (chlorine, UV, ozone), with these requirements in view: food-safety and hygienic design per 3-A / EHEDG.

Results

Since start-up the system has run steadily; the practical result is on-demand dosing, lowering both by-products and cost.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · sterilize — Application Case

Project Overview

The site is reactors, metering vessels and finished-product tanks. The customer wanted sterilize properly configured on the existing plant, with the aim of monitoring and controlling disinfectant dosing and efficacy.

Technical Challenges

What actually causes trouble is highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. All of this means the sterilize configuration has to involve matching monitoring points to the disinfection route (chlorine, UV, ozone).

Configuration

Supply and installation were organised through the analyser range: selecting as part of a complete water-analysis system. On site this meant matching monitoring points to the disinfection route (chlorine, UV, ozone), checked line by line against: Ex certification and GMP traceability of records.

Performance

After commissioning the outcome is on-demand dosing, lowering both by-products and cost, and the readings are now used for process tuning.

Power & Energy

Power & Energy · sterilize — Application Case

Site Conditions

This is a Power & Energy customer whose plant is at boiler feedwater, turbine condensate and FGD/DeNOx systems. The main task was monitoring and controlling disinfectant dosing and efficacy.

The Problem

The difficulty lies in high temperature and pressure with both steam and saline water; at the same time drift under high temperature and pressure, with very costly unplanned outages. Specification therefore means matching monitoring points to the disinfection route (chlorine, UV, ozone).

What We Did

We took a analyser range approach — selecting as part of a complete water-analysis system. Delivery was built around matching monitoring points to the disinfection route (chlorine, UV, ozone), with point-by-point checks on: compliance with power-industry codes and unit availability targets.

Operating Outcome

In service the system performs as intended — on-demand dosing, lowering both by-products and cost, with routine maintenance falling noticeably.