Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

FMR10 Micropilot

FMR10 Micropilot

Micropilot FMR10

Configurable Models 7 models
Micropilot FMR10 offers continuous non-contact level measurement and is a perfect application fit for the water & wastewater industry and utilities across all industries. FMR10 belongs to the first radars with Bluetooth® commissioning, operation and maintenance app. Signal curves can be shown via app on every Bluetooth®-enabled smartphone or tablet (iOS, Android). With the compact design, thanks to unique chip, the device is ideal for limited space applications.
Compare

Continuous / Liquids

Measuring Principle Level radar
Characteristic / Application Simple applications in Water & Wastewater
Utility applications in all industries
Easy storage tanks
Specialities Bluetooth® commissioning,
Operation and maintenance via SmartBlue App
Supply / Communication 2-wire (4…20 mA)
Bluetooth® wireless technology and App
Frequency K-band (~26 GHz)
Accuracy +/- 5 mm (0,2")
Process temperature -40…+60°C
(-40…+140°F)
Process pressure / max. overpressure limit -1…3 bar (-14,50…43 psi)
Main wetted parts PVDF, PBT
Process connection Thread:
G1", NPT1"; G1 1/2", NPT1 1/2"
Max. measurement distance Standard: 8 m (26.2 ft)
With flooding protection tube: 12 m (39.4 ft)
Communication Bluetooth® wireless technology
Certificates / Approvals CSA C/US
Options Flooding protection tube
Different mounting possibilities
Application limits DK < 4:
FMR5x;
Turbulent surfaces:
FMR5x;
Ammoniacal gas phase:
FMR54 in stilling well;
Strong build-up formation:
FMR54 with air purge;
Only PTFE resistant:
FMR52;
Custody transfer measurement:
FMR5xx or NMR8x

The Micropilot FMR10 performs continuous non-contact level measurement and is especially suitable for the water and wastewater industry and for utilities in all industries. The FMR10 is the first non-contact radar to be commissioned, operated and maintained via a Bluetooth® app. The app displays the signal curve on any Bluetooth®-enabled smartphone or tablet (iOS, Android). With its compact design and unique chip, the instrument can be installed and used in confined spaces.

 

Benefits

Non-contact radar commissioned, operated and maintained via a Bluetooth® app

Ultra-compact radar with unique radar chip design for applications in confined spaces

The most cost-effective radar

Especially suited to the water and wastewater industry and utilities in all industries (IP 66 / NEMA4x)

The all-PVDF housing can be installed outdoors; the sealed wiring and fully encapsulated electronics are completely waterproof, allowing use under harsh conditions

Setting just three main parameters satisfies most application requirements

Simple and safe wireless remote access via Bluetooth®, even in hazardous areas or confined spaces

 

Application areas

Radar for continuous level measurement. Can be used in tanks, open basins, pumping stations or sumps.

Process connection: thread

Process temperature: -40...+60 °C (-40...+140 °F)

Process pressure: -1...+3 bar (-14.5...+43 psi)

Measuring range: up to 12 m (26 ft) when a protective stilling well is installed

Measuring accuracy: ± 5 mm (0.2")

Operating frequency: 26 GHz

Spare Parts & Accessories 16

16 spare parts · click to expand
Order codeDescription
917199-0001***Nut, Hex- (A/F41) G1 BK_PA6.6Enquire
71325079可调式安装支架适合FDU90, FMR10, FMR20.Enquire
71093130安装支架Material: 316L. Usage: FDU90/FDU91/FDU91F/FDU92/FDU93/FDU95, FMR10, FMR20.Enquire
71325090***防溢管材质:金属化PBT-PC 适用于40mm/1-1/2"天线且前端过程连接为G1- 1/2"的型号 应用:FMR10,FMR20Enquire
71452315传感器支架 500mm, 316LMounting 1" sensor. Material: 316L. Usage: FDU90, FDU91, FDU91F, FDU92, FDU93, FDU95, FMR10, FMR20, FMR10B, FMR20B.Enquire
71452316传感器支架 1000mm, 316L, US-sensorMounting 1" sensor. Material: 316L. Usage: FDU90, FDU91, FDU91F, FDU92, FDU93, FDU95, FMR10, FMR20, FMR10B, FMR20B.Enquire
52014146安装螺母六角形,SW60 适合FTW31,FTW32,FMI21Details
71429905***Reflector plate horizontal mountingHorizontal mounting bracket for installation in limited space in sewer shaft. Usage: FMR10/FMR20.Enquire
71429910Swiveling mounting bracket, sewerFor installation in manhole above sewer. Material: 316L. Usage: FMR10, FMR20, FMR10B, FMR20B.Enquire
71452318传感器支架 500mm, 316L, 1.5"sensorMounting 1-1/2" sensor. Material: 316L. USage: FMR10, FMR20, FMU30, FMU40, FMR10B, FMR20B, FRM30B.Enquire
71452319传感器支架 1000mm, 316L, 1.5" sensorMounting 1-1/2" sensor. Material: 316L. Usage: FMR10, FMR20, FMU30, FMU40, FMR10B, FMR20B, FMR30B.Enquire
71452326支架 1400mm, 316LPipe diameter: 1". Material: 316L. Usage: FMR10B, FMR20B, FMR30B, FDU90, FDU91, FDU91F, FDU92, FDU93, FDU95, FMR10, FMR20, FMU30, FMU40, FMU41.Enquire
71452327支架 700mm, 316LPipe diameter: 1". Material: 316L. Usage: FMR10B, FMR20B, FMR30B, FDU90, FDU91, FDU91F, FDU92, FDU93, FDU95, FMR10, FMR20, FMU30, FMU40, FMU41.Enquire
71452324安装支架 250x400x120 G1-1/2Material: 316L. Usage: FMR10, FMR20, FMU30, FMU40, FMR10B, FMR20B, FMR30B.Enquire
71452323墙挂式传感器支架, 316LMaterial: 316L. Usage: FMR10B, FMR20B, FMR30B, FDU90, FDU91, FDU91F, FDU92, FDU93, FDU95, FMR10, FMR20, FMU30, FMU40, FMU41.Enquire
52025686遮阳罩材质:PVDF 适合FDU90/FDU91, FMR10, FMR20.Enquire

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

   

Measuring principle video

Click to play

Source: public information from the Endress+Hauser website

7 models · click to expand
Model Name
FMR10-AAQBMWDEWFE2 Radar level transmitter
FMR10-AAQBMWDEWFE2+R7 Radar level transmitter
FMR10-AAQBMVCEVEE2 Radar level transmitter
FMR10-AAQBMVCEWFE2 Radar level transmitter
FMR10-AAQBMVCEWFE2+R7 Radar level transmitter
FMR10-1009/0 Radar level transmitter
FMR10-1144/0 Radar level transmitter
All documents for this model
4 documents · click to expand
BA

BA Micropilot FMR10 Chinese

Rev. 0423 72 pages
Preview
BA

BA Micropilot FMR10 English

Rev. 0423 72 pages
Preview
TI

Micropilot FMR10 Chinese

Rev. 0922 40 pages
Preview
TI

Micropilot FMR10 English

Rev. 0922 40 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · radar — Application Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted radar properly configured on the existing plant, with the aim of continuous radar level measurement of liquids and solids.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the radar configuration has to involve choosing antenna type by dielectric constant, range and process connection.

Configuration

Supply and installation were organised through the level range: level solution matched to the actual tank and silo geometry. On site this meant choosing antenna type by dielectric constant, range and process connection, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is reliable under heavy dust and vapour, reducing manual dipping, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · radar — Application Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was continuous radar level measurement of liquids and solids.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means choosing antenna type by dielectric constant, range and process connection.

What We Did

We took a level range approach — level solution matched to the actual tank and silo geometry. Delivery was built around choosing antenna type by dielectric constant, range and process connection, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — reliable under heavy dust and vapour, reducing manual dipping, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · radar — Application Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from radar , focusing on continuous radar level measurement of liquids and solids.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The radar specification must therefore cover choosing antenna type by dielectric constant, range and process connection.

Delivery Approach

Delivery was handled as the level range — level solution matched to the actual tank and silo geometry. Execution centred on choosing antenna type by dielectric constant, range and process connection, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — reliable under heavy dust and vapour, reducing manual dipping, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · radar — Application Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is radar ; the focus is continuous radar level measurement of liquids and solids.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with choosing antenna type by dielectric constant, range and process connection.

Implementation

The scope ran through the level range: level solution matched to the actual tank and silo geometry. Technically it hinges on choosing antenna type by dielectric constant, range and process connection, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means reliable under heavy dust and vapour, reducing manual dipping, which cut the workload on the site maintenance team.