Micropilot FMR10
Technical Data
CompareContinuous / Liquids
| Measuring Principle | Level radar |
| Characteristic / Application | Simple applications in Water & Wastewater Utility applications in all industries Easy storage tanks |
| Specialities | Bluetooth® commissioning, Operation and maintenance via SmartBlue App |
| Supply / Communication | 2-wire (4…20 mA) Bluetooth® wireless technology and App |
| Frequency | K-band (~26 GHz) |
| Accuracy | +/- 5 mm (0,2") |
| Process temperature | -40…+60°C (-40…+140°F) |
| Process pressure / max. overpressure limit | -1…3 bar (-14,50…43 psi) |
| Main wetted parts | PVDF, PBT |
| Process connection | Thread: G1", NPT1"; G1 1/2", NPT1 1/2" |
| Max. measurement distance | Standard: 8 m (26.2 ft) With flooding protection tube: 12 m (39.4 ft) |
| Communication | Bluetooth® wireless technology |
| Certificates / Approvals | CSA C/US |
| Options | Flooding protection tube Different mounting possibilities |
| Application limits | DK < 4: FMR5x; Turbulent surfaces: FMR5x; Ammoniacal gas phase: FMR54 in stilling well; Strong build-up formation: FMR54 with air purge; Only PTFE resistant: FMR52; Custody transfer measurement: FMR5xx or NMR8x |
The Micropilot FMR10 performs continuous non-contact level measurement and is especially suitable for the water and wastewater industry and for utilities in all industries. The FMR10 is the first non-contact radar to be commissioned, operated and maintained via a Bluetooth® app. The app displays the signal curve on any Bluetooth®-enabled smartphone or tablet (iOS, Android). With its compact design and unique chip, the instrument can be installed and used in confined spaces.
Benefits
Non-contact radar commissioned, operated and maintained via a Bluetooth® app
Ultra-compact radar with unique radar chip design for applications in confined spaces
The most cost-effective radar
Especially suited to the water and wastewater industry and utilities in all industries (IP 66 / NEMA4x)
The all-PVDF housing can be installed outdoors; the sealed wiring and fully encapsulated electronics are completely waterproof, allowing use under harsh conditions
Setting just three main parameters satisfies most application requirements
Simple and safe wireless remote access via Bluetooth®, even in hazardous areas or confined spaces
Application areas
Radar for continuous level measurement. Can be used in tanks, open basins, pumping stations or sumps.
Process connection: thread
Process temperature: -40...+60 °C (-40...+140 °F)
Process pressure: -1...+3 bar (-14.5...+43 psi)
Measuring range: up to 12 m (26 ft) when a protective stilling well is installed
Measuring accuracy: ± 5 mm (0.2")
Operating frequency: 26 GHz
Spare Parts & Accessories 16
16 spare parts · click to expand
| Order code | Description | |
|---|---|---|
| 917199-0001 | ***Nut, Hex- (A/F41) G1 BK_PA6.6 | Enquire |
| 71325079 | 可调式安装支架适合FDU90, FMR10, FMR20. | Enquire |
| 71093130 | 安装支架Material: 316L. Usage: FDU90/FDU91/FDU91F/FDU92/FDU93/FDU95, FMR10, FMR20. | Enquire |
| 71325090 | ***防溢管材质:金属化PBT-PC 适用于40mm/1-1/2"天线且前端过程连接为G1- 1/2"的型号 应用:FMR10,FMR20 | Enquire |
| 71452315 | 传感器支架 500mm, 316LMounting 1" sensor. Material: 316L. Usage: FDU90, FDU91, FDU91F, FDU92, FDU93, FDU95, FMR10, FMR20, FMR10B, FMR20B. | Enquire |
| 71452316 | 传感器支架 1000mm, 316L, US-sensorMounting 1" sensor. Material: 316L. Usage: FDU90, FDU91, FDU91F, FDU92, FDU93, FDU95, FMR10, FMR20, FMR10B, FMR20B. | Enquire |
| 52014146 | 安装螺母六角形,SW60 适合FTW31,FTW32,FMI21 | Details |
| 71429905 | ***Reflector plate horizontal mountingHorizontal mounting bracket for installation in limited space in sewer shaft. Usage: FMR10/FMR20. | Enquire |
| 71429910 | Swiveling mounting bracket, sewerFor installation in manhole above sewer. Material: 316L. Usage: FMR10, FMR20, FMR10B, FMR20B. | Enquire |
| 71452318 | 传感器支架 500mm, 316L, 1.5"sensorMounting 1-1/2" sensor. Material: 316L. USage: FMR10, FMR20, FMU30, FMU40, FMR10B, FMR20B, FRM30B. | Enquire |
| 71452319 | 传感器支架 1000mm, 316L, 1.5" sensorMounting 1-1/2" sensor. Material: 316L. Usage: FMR10, FMR20, FMU30, FMU40, FMR10B, FMR20B, FMR30B. | Enquire |
| 71452326 | 支架 1400mm, 316LPipe diameter: 1". Material: 316L. Usage: FMR10B, FMR20B, FMR30B, FDU90, FDU91, FDU91F, FDU92, FDU93, FDU95, FMR10, FMR20, FMU30, FMU40, FMU41. | Enquire |
| 71452327 | 支架 700mm, 316LPipe diameter: 1". Material: 316L. Usage: FMR10B, FMR20B, FMR30B, FDU90, FDU91, FDU91F, FDU92, FDU93, FDU95, FMR10, FMR20, FMU30, FMU40, FMU41. | Enquire |
| 71452324 | 安装支架 250x400x120 G1-1/2Material: 316L. Usage: FMR10, FMR20, FMU30, FMU40, FMR10B, FMR20B, FMR30B. | Enquire |
| 71452323 | 墙挂式传感器支架, 316LMaterial: 316L. Usage: FMR10B, FMR20B, FMR30B, FDU90, FDU91, FDU91F, FDU92, FDU93, FDU95, FMR10, FMR20, FMU30, FMU40, FMU41. | Enquire |
| 52025686 | 遮阳罩材质:PVDF 适合FDU90/FDU91, FMR10, FMR20. | Enquire |
Configurator / Comparison
Measuring principle video
Click to playSource: public information from the Endress+Hauser website
Manuals & Documents 4
All documents for this modelCase Studies
Municipal Wastewater Treatment · radar — Application Case
Project Overview
The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted radar properly configured on the existing plant, with the aim of continuous radar level measurement of liquids and solids.
Technical Challenges
What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the radar configuration has to involve choosing antenna type by dielectric constant, range and process connection.
Configuration
Supply and installation were organised through the level range: level solution matched to the actual tank and silo geometry. On site this meant choosing antenna type by dielectric constant, range and process connection, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.
Performance
After commissioning the outcome is reliable under heavy dust and vapour, reducing manual dipping, and the readings are now used for process tuning.
Food & Beverage · radar — Application Case
Site Conditions
This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was continuous radar level measurement of liquids and solids.
The Problem
The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means choosing antenna type by dielectric constant, range and process connection.
What We Did
We took a level range approach — level solution matched to the actual tank and silo geometry. Delivery was built around choosing antenna type by dielectric constant, range and process connection, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.
Operating Outcome
In service the system performs as intended — reliable under heavy dust and vapour, reducing manual dipping, with routine maintenance falling noticeably.
Chemical & Pharmaceutical · radar — Application Case
Application Context
reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from radar , focusing on continuous radar level measurement of liquids and solids.
Process Constraints
corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The radar specification must therefore cover choosing antenna type by dielectric constant, range and process connection.
Delivery Approach
Delivery was handled as the level range — level solution matched to the actual tank and silo geometry. Execution centred on choosing antenna type by dielectric constant, range and process connection, together with Ex certification and GMP traceability of records.
Field Results
Operation shows the benefit clearly — reliable under heavy dust and vapour, reducing manual dipping, with confidence in this measuring point improving markedly.
Power & Energy · radar — Application Case
Customer Profile
The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is radar ; the focus is continuous radar level measurement of liquids and solids.
Key Difficulties
Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with choosing antenna type by dielectric constant, range and process connection.
Implementation
The scope ran through the level range: level solution matched to the actual tank and silo geometry. Technically it hinges on choosing antenna type by dielectric constant, range and process connection, and on these requirements: compliance with power-industry codes and unit availability targets.
Customer Benefit
In practice this means reliable under heavy dust and vapour, reducing manual dipping, which cut the workload on the site maintenance team.
Related Products
Endress+HauserMicropilot FMR20
Endress+HauserMicropilot FMR50
Endress+HauserMicropilot FMR56
Endress+HauserMicropilot FMR52
Endress+HauserMicropilot FMR60
Endress+HauserMicropilot FMR57
Endress+HauserMicropilot FMR62
Endress+Hauser