Micropilot FMR60
Technical Data
CompareContinuous / Liquids
| Measuring Principle | Level radar |
| Characteristic / Application | For basic level measurement in liquids, pastes and slurries; non affected by changing media, temperature changes, gas blankets or vapor; For applications with many obstacles due to the very small beam angle. |
| Specialities | Heartbeat Technology, SIL 2/3 according to IEC 61508, Bluetooth® commissioning, Operation and maintenance SmartBlue App, Safety and reliability with Multi-Echo Tracking HistoROM RFID TAG for easy identification |
| Supply / Communication | 2-wire (HART) Bluetooth® wireless technology and App (optional) |
| Frequency | W-band (~80 GHz) |
| Accuracy | +/- 1 mm (0.04 in) |
| Ambient temperature | -40…+80 °C (-40…+176 °F) |
| Process temperature | -40…+130 °C (-40…+266 °F) |
| Process pressure / max. overpressure limit | Vacuum …16 bar (Vacuum … 232 psi) |
| Main wetted parts | PTFE antenna PP or 316L process connections |
| Process connection | Thread: G1-1/2", MNPT1-1/2"; Flange: UNI DN80…DN150 (3"…6") |
| Max. measurement distance | 50 m (164 ft) |
| Communication | 4…20 mA HART, Additional switch, Bluetooth® wireless technology |
| Certificates / Approvals | ATEX, FM, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, KC, EAC, UK Ex |
| Safety approvals | Overfill protection WHG SIL 2, SIL 3 |
| Design approvals | EN 10204-3.1 |
| Options | Display, Customized parameterization, Remote operation via SmartBlue App using Bluetooth®, Gas-tight feed through, PWIS free |
| Application limits | Process temp. > 130 °C (266 °F) -> FMR62 Very aggressive media -> FMR62 Strong turbulences and foam, stilling well and bypass -> FMR5x, FMP5x |
Micropilot FMR60 is the first 80 GHz radar designed in accordance with the IEC 61508 international functional safety standard. The non-contact radar uses a droplet antenna, improved algorithms and a small beam angle for maximum reliability. It enables non-contact continuous level measurement of liquids, pastes and sludge. The measurement result is unaffected by changes in the medium, temperature fluctuations, gas phase layer or vapor. In addition, it is equipped with Heartbeat Technology intelligent sensor functions.
Benefits
Hardware and software designed in accordance with IEC 61508, achieving maximum safety SIL3 in redundant systems
Heartbeat Technology ensures economical and safe operation of the device throughout its entire life cycle
The HistoROM data management concept enables fast and simple commissioning, maintenance and diagnostics
Small beam angle and multi-echo tracking algorithm ensure maximum reliability of measurement in vessels with internal obstacles
The 80 GHz radar can be integrated into the process more conveniently, reducing design effort
The innovative droplet antenna is made of PTFE for maximum system suitability
The world's simplest SIL proof test concept, along with WHG, saving time and costs
Application
The 80 GHz droplet antenna can measure in free space with a maximum range of 50 m, has a highly focused beam angle and is suitable for applications with multiple obstructions in the vessel.
Process connection: thread or flange
Temperature: -40...+130°C (-40...+266°F)
Pressure: –1...+16 bar (–14.5...+232 psi)
Measuring range: Max. 50 m (164 ft)
Measuring accuracy: ±1 mm (0.04 in)
W-band: 80 GHz
International explosion protection certificates, WHG overflow protection approval, SIL, marine approval, 5-point linearity protocol
E+H Product Configurator
Please enter the product model to configure
Product Comparison
Please enter the product models to compare in the fields below. Up to three products can be compared
Technical Documentation
Technical Specifications
Documents/Manuals/Software
Accessories/Spare Parts
Measuring Principle Video
Source:Endress+Hauserwebsite public information
Case Studies
Municipal Wastewater Treatment — Wastewater Treatment Plant · Radar Application Case
Project Background
Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Radar.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Radar for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage — Food Production Line · Radar Application Case
Project Background
Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Radar.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Radar for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical — Reactors and Storage Tanks · Radar Application Case
Project Background
Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Radar.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Radar for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy — Power Plant Boiler and Turbine · Radar Application Case
Project Background
Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Radar.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Radar for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.