Micropilot FMR20 performs continuous non-contact level and flow measurement (via linearization table) and is especially suitable for the water and wastewater industry as well as utilities in all industries. It can be commissioned via HART or wirelessly using the Bluetooth® app or a remote display unit. The app can display signal curves on any Bluetooth®-enabled smartphone or tablet (iOS, Android). With its compact design and unique chip, the device can be installed and used in confined spaces.
Benefits
Non-contact radar commissioned via HART or wirelessly using the Bluetooth® app or a remote display unit
Ultra-compact radar with unique radar chip design, meeting the requirements of confined-space applications
Radar with the best price-performance ratio
Especially suitable for the water and wastewater industry and utilities in all industries (IP66, 68 / NEMA4x, 6P)
The all-PVDF housing can be installed outdoors; sealed wiring and fully encapsulated electronics are completely waterproof and suitable for harsh conditions
Simple setting of three main parameters meets most application requirements
Simple and safe wireless remote access via Bluetooth®, even for use in hazardous areas or confined spaces
Application
Radar for continuous level measurement and flow measurement (in open channels or measuring weirs, via linearization table). Can be used in storage tanks, open basins, pumping stations or sewer basins.
Process connection: thread, flange
Process temperature: -40...+80°C (-40...+176°F)
Process pressure: -1...+3 bar (-14.5...+43 psi)
Maximum measuring range for liquids: 15 m (33 ft), 20 m (66 ft)
Maximum measuring range for solids: 10 m (33 ft)
Measuring accuracy: ± 2 mm (0.08")
Operating frequency: 26 GHz
International explosion protection approval
Spare Parts & Accessories 25
25 spare parts · click to collapse
| Order code | Description | |
|---|---|---|
| 52000598 | Plastic ring | Hexagon nut (SW70) G2, bk, PCfor sensor 2" Prosonic T/Prosonic M | Details |
| 71162777 | Angle adjustment device 3"/DN80/80, horn 80 mmNPS 3" Cl.150 / DN80 PN16 / 10K 80. Max 4bar abs/58psia. Material: PP. Usage: 80mm/3" horn. Usage: FMR20, FMR50, FMR56, FMR20B, FMR30B. | Details |
| 71162778 | angle adjustment device 4"/DN100/100, horn 80mmNPS 4" Cl.150 / DN100 PN16 / 10K 100. Max 4bar abs/58psia. Material: PP. Usage: 80mm/3" horn. Usage: FMR20, FMR50, FMR56, FMR20B, FMR30B. | Details |
| 71162780 | Angle adjustment device 6"/DN150/150, horn 80 mmNPS 6" Cl.150 / DN150 PN16 / 10K 150. Max 4bar abs/58psia. Material: PP. Usage: 80mm/3" horn. Usage: FMR20, FMR50, FMR56, FMR20B, FMR30B. | Details |
| 71325087 | HART communication resistorUsage: FMG50, FMR20, FMX21 with RIA15. | Details |
| 52014146 | mounting nut六角形,SW60 适合FTW31,FTW32,FMI21 | Details |
| 71325090 | *** anti-overflow pipe材质:金属化PBT-PC 适用于40mm/1-1/2"天线且前端过程连接为G1- 1/2"的型号 应用:FMR10,FMR20 | Details |
| 71327051 | *** anti-overflow pipeMaterial: metallized PBT-PC. Suitable for 80mm/3" antenna. Usage: FMR20. | Details |
| 71093130 | mounting bracketMaterial: 316L. Usage: FDU90/FDU91/FDU91F/FDU92/FDU93/FDU95, FMR10, FMR20. | Details |
| 71325079 | adjustable mounting bracket适合FDU90, FMR10, FMR20. | Details |
| 52025686 | Sunshade材质:PVDF 适合FDU90/FDU91, FMR10, FMR20. | Details |
| 71429905 | Reflector plate, horizontal mountingHorizontal mounting bracket for installation in limited space in sewer shaft. Usage: FMR10/FMR20. | Details |
| 71429910 | Swiveling mounting bracket, sewerFor installation in manhole above sewer. Material: 316L. Usage: FMR10, FMR20, FMR10B, FMR20B. | Details |
| 71452315 | Sensor bracket 500 mm, 316LMounting 1" sensor. Material: 316L. Usage: FDU90, FDU91, FDU91F, FDU92, FDU93, FDU95, FMR10, FMR20, FMR10B, FMR20B. | Details |
| 71452316 | Sensor bracket 1000mm, 316L, US-sensorMounting 1" sensor. Material: 316L. Usage: FDU90, FDU91, FDU91F, FDU92, FDU93, FDU95, FMR10, FMR20, FMR10B, FMR20B. | Details |
| FAX50- | Threaded Flange FAX50Usage: FMP50, FMP51, FMP52, FMP53, FMP54, FMP55, FMP56, FMP57, FMR20, FMR20B, FMR30B, FMR60, FMR67, FMR60B, FMR66B, FMU30, FMU40, FMU41, FMU42, FMU44, FDU90, FDU91, FDU92, FDU93, FDU95, FTI51, FTI52, FTI55, FTI56, FTI77. | Enquire |
| 71452323 | Wall-mounted sensor bracket, 316LMaterial: 316L. Usage: FMR10B, FMR20B, FMR30B, FDU90, FDU91, FDU91F, FDU92, FDU93, FDU95, FMR10, FMR20, FMU30, FMU40, FMU41. | Details |
| 71452324 | Mounting bracket 250x400x120 G1-1/2Material: 316L. Usage: FMR10, FMR20, FMU30, FMU40, FMR10B, FMR20B, FMR30B. | Details |
| 71452325 | Mounting bracket 250x400x120 G2Material: 316L. Usage: FMR10B, FMR20B, FMR30B, FMR20, FMU30, FMU41. | Details |
| 71452318 | Sensor bracket 500mm, 316L, 1.5" sensorMounting 1-1/2" sensor. Material: 316L. USage: FMR10, FMR20, FMU30, FMU40, FMR10B, FMR20B, FRM30B. | Details |
Configurator / Comparison
Measuring Principle Video
Click to playSource:Endress+Hauserwebsite public information
12 documents · click to expand
Micropilot FMR20 Modbus RS485 操作手册 Chinese
Micropilot FMR20 HART 操作手册 Chinese
Micropilot FMR20 MODBUS RS485 English
Micropilot FMR20 HART English
Micropilot FMR20 MODBUS RS485 English
Micropilot FMR20 HART English
Micropilot FMR20 HART Chinese
Micropilot FMR20 Modbus RS485 Chinese
TI 文丘里水槽QV302...QV316 Chinese
TI Micropilot FMR20 (Solid) Modbus RS485 Chinese
Micropilot FMR20 HART English
Micropilot FMR20 Modbus RS485 English
Case Studies
Municipal Wastewater Treatment · radar — Application Case
Project Overview
The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted radar properly configured on the existing plant, with the aim of continuous radar level measurement of liquids and solids.
Technical Challenges
What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the radar configuration has to involve choosing antenna type by dielectric constant, range and process connection.
Configuration
Supply and installation were organised through the level range: level solution matched to the actual tank and silo geometry. On site this meant choosing antenna type by dielectric constant, range and process connection, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.
Performance
After commissioning the outcome is reliable under heavy dust and vapour, reducing manual dipping, and the readings are now used for process tuning.
Food & Beverage · radar — Application Case
Site Conditions
This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was continuous radar level measurement of liquids and solids.
The Problem
The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means choosing antenna type by dielectric constant, range and process connection.
What We Did
We took a level range approach — level solution matched to the actual tank and silo geometry. Delivery was built around choosing antenna type by dielectric constant, range and process connection, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.
Operating Outcome
In service the system performs as intended — reliable under heavy dust and vapour, reducing manual dipping, with routine maintenance falling noticeably.
Chemical & Pharmaceutical · radar — Application Case
Application Context
reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from radar , focusing on continuous radar level measurement of liquids and solids.
Process Constraints
corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The radar specification must therefore cover choosing antenna type by dielectric constant, range and process connection.
Delivery Approach
Delivery was handled as the level range — level solution matched to the actual tank and silo geometry. Execution centred on choosing antenna type by dielectric constant, range and process connection, together with Ex certification and GMP traceability of records.
Field Results
Operation shows the benefit clearly — reliable under heavy dust and vapour, reducing manual dipping, with confidence in this measuring point improving markedly.
Power & Energy · radar — Application Case
Customer Profile
The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is radar ; the focus is continuous radar level measurement of liquids and solids.
Key Difficulties
Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with choosing antenna type by dielectric constant, range and process connection.
Implementation
The scope ran through the level range: level solution matched to the actual tank and silo geometry. Technically it hinges on choosing antenna type by dielectric constant, range and process connection, and on these requirements: compliance with power-industry codes and unit availability targets.
Customer Benefit
In practice this means reliable under heavy dust and vapour, reducing manual dipping, which cut the workload on the site maintenance team.