Source container FQG60
Technical Data
CompareContinuous / Liquids
| Measuring Principle | Radiometric |
| Characteristic / Application | Source container Emission angle: 40 / 20 degrees Approximately 18kg |
| Specialities | With manual switch-on and switch-off |
| Ambient temperature | –40...+120 °C (–40...+248 °F) |
| Process temperature | Any |
| Process pressure / max. overpressure limit | Any |
| Main wetted parts | Non-contact |
| Process connection | Non-contact |
Continuous / Solids
| Measuring Principle | Radiometric |
| Characteristic / Application | Source container Emission angle: 40 / 20 degrees Approximately 18kg |
| Specialities | Control area calculation with Applicator |
| Ambient temperature | –40...+120 °C (–40...+248 °F) |
| Process temperature | Any |
| Process pressure / max. overpressure limit | Any |
| Main wetted parts | Non-contact |
| Process connection | Non-contact |
Density
| Measuring Principle | Radiometric Density |
| Characteristic / Application | Source container Emission angle: 5/ 20 / 40 degrees Approximately 18kg |
| Ambient temperature | –40...+120 °C (–40...+248 °F) |
| Process temperature | Any |
| Process pressure | Any |
| Wetted parts | Non-contact |
| Hygienic | Non-contact |
| Specialities | Control area calculation with Applicator |
Point Level / Liquids
| Measuring Principle | Radiometric Limit |
| Characteristic / Application | Source container Emission angle: 5 degrees Approximately 18kg |
| Specialities | Control area calculation with Applicator |
| Ambient temperature | –40 ...+120 °C (–40 ...+248 °F) |
| Process temperature | Any |
| Process pressure / max. overpressure limit | Any |
| Main wetted parts | Non-contact |
| Process connection | Non-contact |
Point Level / Solids
| Measuring Principle | Radiometric Limit |
| Characteristic / Application | Source container Emission angle: 5 degrees Approximately 18kg |
| Specialities | Control area calculation with Applicator |
| Ambient temperature | –40...+120 °C (–40...+248 °F) |
| Process temperature | Any |
| Process pressure / max. overpressure limit | Any |
| Main wetted parts | Non-contact |
| Process connection | Non-contact |
The FQG60 source container holds a radioactive source and is used for radiometric limit detection as well as continuous level and density measurement. The radiation is emitted almost unattenuated in only one direction and is shielded in all other directions, ensuring maximum personal safety and reliable measurement.
Advantages
Small size and low weight, providing optimum shielding
Radioactive source of the highest safety class (DIN 25426/ISO 2919, typical classification C66646)
Fire-resistant 821°C / 30 minutes
Integrated device for convenient installation
Multiple radiation angles for optimum application results
Integrated installation device for pipe density measurement
Manual opening and closing
Application
The FQG60 source container is used to house the radioactive source during radiometric limit detection and continuous level and density measurement. The radiation is emitted almost unattenuated in only one direction and is shielded in all other directions.
E+H Product Configurator
Please enter the product model to configure
Product comparison
Please enter the product models to compare in the boxes below (max. three products)
Technical documentation
Technical data
Documents/Manuals/Software
Accessories/Spare parts
Source:Endress+Hauserwebsite public information
Case Studies
Municipal Wastewater Treatment — Wastewater Treatment Plant · Radiometric Application Case
Project Background
Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Radiometric.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Radiometric for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage — Food Production Line · Radiometric Application Case
Project Background
Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Radiometric.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Radiometric for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical — Reactors and Storage Tanks · Radiometric Application Case
Project Background
Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Radiometric.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Radiometric for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy — Power Plant Boiler and Turbine · Radiometric Application Case
Project Background
Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Radiometric.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Radiometric for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Related Products
Endress+HauserGammapilot FMG50
Endress+HauserSource container FQG62
Endress+HauserSource container FQG66
Endress+HauserGamma source FSG61, Co60
Endress+HauserGamma source FSG60, Cs137
Endress+HauserGammapilot M FMG60
Endress+HauserSource container FQG63
Endress+Hauser