Technical Data
CompareContinuous / Liquids
| Measuring Principle | Radiometric |
| Characteristic / Application | Source container Emission angle: 40 / 20 degrees Approximately 18kg |
| Specialities | With manual switch-on and switch-off |
| Ambient temperature | –40...+120 °C (–40...+248 °F) |
| Process temperature | Any |
| Process pressure / max. overpressure limit | Any |
| Main wetted parts | Non-contact |
| Process connection | Non-contact |
Continuous / Solids
| Measuring Principle | Radiometric |
| Characteristic / Application | Source container Emission angle: 40 / 20 degrees Approximately 18kg |
| Specialities | Control area calculation with Applicator |
| Ambient temperature | –40...+120 °C (–40...+248 °F) |
| Process temperature | Any |
| Process pressure / max. overpressure limit | Any |
| Main wetted parts | Non-contact |
| Process connection | Non-contact |
Density
| Measuring Principle | Radiometric Density |
| Characteristic / Application | Source container Emission angle: 5/ 20 / 40 degrees Approximately 18kg |
| Ambient temperature | –40...+120 °C (–40...+248 °F) |
| Process temperature | Any |
| Process pressure | Any |
| Wetted parts | Non-contact |
| Hygienic | Non-contact |
| Specialities | Control area calculation with Applicator |
Point Level / Liquids
| Measuring Principle | Radiometric Limit |
| Characteristic / Application | Source container Emission angle: 5 degrees Approximately 18kg |
| Specialities | Control area calculation with Applicator |
| Ambient temperature | –40 ...+120 °C (–40 ...+248 °F) |
| Process temperature | Any |
| Process pressure / max. overpressure limit | Any |
| Main wetted parts | Non-contact |
| Process connection | Non-contact |
Point Level / Solids
| Measuring Principle | Radiometric Limit |
| Characteristic / Application | Source container Emission angle: 5 degrees Approximately 18kg |
| Specialities | Control area calculation with Applicator |
| Ambient temperature | –40...+120 °C (–40...+248 °F) |
| Process temperature | Any |
| Process pressure / max. overpressure limit | Any |
| Main wetted parts | Non-contact |
| Process connection | Non-contact |
The FQG60 source container holds a radioactive source and is used for radiometric limit detection as well as continuous level and density measurement. The radiation is emitted almost unattenuated in only one direction and is shielded in all other directions, ensuring maximum personal safety and reliable measurement.
Advantages
-
Small size and low weight, providing optimum shielding
-
Radioactive source of the highest safety class (DIN 25426/ISO 2919, typical classification C66646)
-
Fire-resistant 821°C / 30 minutes
-
Integrated device for convenient installation
-
Multiple radiation angles for optimum application results
-
Integrated installation device for pipe density measurement
-
Manual opening and closing
Application
The FQG60 source container is used to house the radioactive source during radiometric limit detection and continuous level and density measurement. The radiation is emitted almost unattenuated in only one direction and is shielded in all other directions.
Spare Parts & Accessories 4
4 spare parts · click to collapse
| Order code | Description | |
|---|---|---|
| 71099421 | nameplateWhen changing the source. Consists of: 1x label "radioactive". 3x nameplate, blank. Grooved drive stud, seal wire. Usage: FQG60/FQG61/FQG62/FQG63. | Details |
| 71301302 | padlockWith key, simultaneous locking. Usage: FQG61/FQG62/FQG66. | Details |
| 71130944 | Hook, for fixing the position of the radioactive source, suitable for FQG60Snap hook for fix switching position ON. Usage: FQG60. | Details |
| 916497-0000 | Label "caution radiation" _SSCorrosion resistant steel, 304. | Details |
Configurator / Comparison
Source:Endress+Hauserwebsite public information
Manuals & Documents 2
All documents for this modelCase Studies
Municipal Wastewater Treatment · radiant — Application Case
Site Conditions
This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was non-contact level measurement in extreme duty using radiometric principles.
The Problem
The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means sizing source strength against wall thickness, density and licensing requirements.
What We Did
We took a level range approach — level solution matched to the actual tank and silo geometry. Delivery was built around sizing source strength against wall thickness, density and licensing requirements, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.
Operating Outcome
In service the system performs as intended — measurable under high temperature, pressure and corrosion without intruding into the vessel, with routine maintenance falling noticeably.
Food & Beverage · radiant — Application Case
Application Context
dosing, pasteurising, filling and CIP stages is a typical Food & Beverage duty. The project started from radiant, focusing on non-contact level measurement in extreme duty using radiometric principles.
Process Constraints
frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, and syrups, dairy and beverages that scale easily, under strict hygienic requirements only amplify it. The radiant specification must therefore cover sizing source strength against wall thickness, density and licensing requirements.
Delivery Approach
Delivery was handled as the level range — level solution matched to the actual tank and silo geometry. Execution centred on sizing source strength against wall thickness, density and licensing requirements, together with food-safety and hygienic design per 3-A / EHEDG.
Field Results
Operation shows the benefit clearly — measurable under high temperature, pressure and corrosion without intruding into the vessel, with confidence in this measuring point improving markedly.
Chemical & Pharmaceutical · radiant — Application Case
Customer Profile
The typical setting in Chemical & Pharmaceutical is reactors, metering vessels and finished-product tanks. The measuring point is radiant; the focus is non-contact level measurement in extreme duty using radiometric principles.
Key Difficulties
Conditions are highly corrosive media with solvents and crystallisation, partly in explosive atmospheres and, on top of that, corrosion plus Ex protection shortens instrument life and makes downtime costly, which a standard configuration cannot handle for long. The design therefore starts with sizing source strength against wall thickness, density and licensing requirements.
Implementation
The scope ran through the level range: level solution matched to the actual tank and silo geometry. Technically it hinges on sizing source strength against wall thickness, density and licensing requirements, and on these requirements: Ex certification and GMP traceability of records.
Customer Benefit
In practice this means measurable under high temperature, pressure and corrosion without intruding into the vessel, which cut the workload on the site maintenance team.
Power & Energy · radiant — Application Case
Project Background
The project covers boiler feedwater, turbine condensate and FGD/DeNOx systems. The work centres on radiant and the core task is non-contact level measurement in extreme duty using radiometric principles.
Operating Challenges
The medium and duty are characterised by high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. So radiant cannot be specified generically — it calls for sizing source strength against wall thickness, density and licensing requirements.
Solution
The Ainstru engineering team worked through the level range: level solution matched to the actual tank and silo geometry. The configuration involves sizing source strength against wall thickness, density and licensing requirements, with these requirements in view: compliance with power-industry codes and unit availability targets.
Results
Since start-up the system has run steadily; the practical result is measurable under high temperature, pressure and corrosion without intruding into the vessel.
Related Products
Endress+HauserGammapilot FMG50
Endress+HauserGamma source FSG61, Co60
Endress+HauserSource container FQG62
Endress+HauserSource container FQG66
Endress+HauserGamma source FSG60, Cs137
Endress+HauserGammapilot M FMG60
Endress+HauserSource container FQG63
Endress+Hauser