FQG66 Source container

FQG66 Source container
Source container FQG66
The FQG66 source container is designed to hold the radioactive source with highest activities during radiometric point level detection, continuous level and density measurement. The radiation is emitted almost unattenuated in one direction only, and is damped in all other directions. This guarantees highest safety for the personnel and a reliable measurement.
Compare

Continuous / Liquids

Measuring Principle Radiometric
Characteristic / Application Source container
Emission angle: 40 / 20 degrees
435kg
Specialities Sliding source support rod for manual or pneumatic on/ off switching
Ambient temperature -55 °C...+100 °C
(-67 °F...+212 °F)
Process temperature Any
Process pressure / max. overpressure limit Any
Main wetted parts Non-contact
Process connection Non-contact

Continuous / Solids

Measuring Principle Radiometric
Characteristic / Application Source container
Emission angle: 40 / 20 degrees
435kg
Specialities Control area calculation with Applicator
Ambient temperature -55 °C...+100 °C
(-67 °F...+212 °F)
Process temperature Any
Process pressure / max. overpressure limit Any
Main wetted parts Non-contact
Process connection Non-contact

Density

Measuring Principle Radiometric Density
Characteristic / Application Source container
Emission angle: 5/ 20 / 40 degrees
435kg
Ambient temperature -55 °C...+100 °C
(-67 °F...+212 °F)
Process temperature Any
Process pressure Any
Wetted parts Non-contact
Hygienic Non-contact
Specialities Control area calculation with Applicator

Point Level / Liquids

Measuring Principle Radiometric Limit
Characteristic / Application Source container
Emission angle: 5 degrees
Approximately 435 kg
Specialities Control area calculation with Applicator
Ambient temperature -55 °C ... +100 °C
(-67 °F ...+212 °F)
Process temperature Any
Process pressure / max. overpressure limit Any
Main wetted parts Non- contact
Process connection Non- contact
Process connection hygienic Non- contact

Point Level / Solids

Measuring Principle Radiometric Limit
Characteristic / Application Source container
Emission angle: 5 degrees
435kg
Specialities Control area calculation with Applicator
Ambient temperature -55 °C...+100 °C
(-67 °F...+212 °F)
Process temperature Any
Process pressure / max. overpressure limit Any
Main wetted parts Non- contact
Process connection Non- contact
Process connection hygienic Non- contact

The radiation source capsule FQG66 is used to house the radiation source in radiometric limit detection, continuous level measurement and density measurement. The radiation is emitted almost without attenuation in only one direction and is shielded in all other directions, ensuring maximum personnel safety and measurement reliability.

Benefits

  • Highest safety class (DIN 25426/ISO 2919, typical class C66646), allowing simple and convenient source replacement

  • Extremely strong shielding effect, direct installation without a controlled area

  • Additional metal source capsule with O-ring seal protects the source from mechanical and chemical influences

  • Small space requirement, simple installation and various radiation angles for optimum application results

  • Open/close switch position locked with a padlock for anti-theft protection

  • Switch status conveniently visible through the glass window in the cover or via the remote display of a proximity switch

Applications

  • Houses the radiation source for radiometric limit detection, level and density measurement. Highly sensitive rod-type scintillator detectors minimize the surrounding radiation dose

  • Used when the shielding effect of smaller source capsules (FQG61/62) is insufficient

  • Source activity: 740 GBq (20,000 mCi) for 137Cs, 185 GBq (5,000 mCi) for 60Co

  • Process temperature: unrestricted (external installation)

  • Process pressure: unrestricted (external installation)

Spare Parts & Accessories 9

9 spare parts · click to collapse
Order codeDescription
71301286O-ringO-ring 138.0x6.0 FVMQ. Usage: FQG66.Details
71301296plain bearing assemblyConsists of: bearing bush, thrust washer. Usage: FQG66.Details
71341171boltConsisting of: Bolt, fixing wire with sleeve. Usage: FQG66.Details
71301299Sight glass FQG66, sealMaterial: 1.4305. Window: glas. Flat seal: FVMQ. Usage: hood FQG66.Details
71301302padlockWith key, simultaneous locking. Usage: FQG61/FQG62/FQG66.Details
71301303ScrewConsists of: ventilation screw 304. Pressure compensation filter. O-ring VMQ, protection lid. Usage: hood FQG66.Details
71099277Proximity switchUsage: FQG61/FQG62/FQG66. Two pieces per instrument are required.Details
71301298Junction BoxWith fixing screws. Usage: FQG66.Details
916497-0000Label "caution radiation" _SSCorrosion resistant steel, 304.Details

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

Source: Endress+Hauserpublic information from the website

All documents for this model
4 documents · click to expand
BA

BA FQG66源盒 Chinese

Rev. 0220 40 pages
Preview
BA

BA Source container FQG66 English

Rev. 0425 76 pages
Preview
TI

TI FQG66源盒 Chinese

Rev. 0320 24 pages
Preview
TI

Source container FQG66 English

Rev. 0320 24 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · radiant — Application Case

Site Conditions

This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was non-contact level measurement in extreme duty using radiometric principles.

The Problem

The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means sizing source strength against wall thickness, density and licensing requirements.

What We Did

We took a level range approach — level solution matched to the actual tank and silo geometry. Delivery was built around sizing source strength against wall thickness, density and licensing requirements, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.

Operating Outcome

In service the system performs as intended — measurable under high temperature, pressure and corrosion without intruding into the vessel, with routine maintenance falling noticeably.

Food & Beverage

Food & Beverage · radiant — Application Case

Application Context

dosing, pasteurising, filling and CIP stages is a typical Food & Beverage duty. The project started from radiant, focusing on non-contact level measurement in extreme duty using radiometric principles.

Process Constraints

frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, and syrups, dairy and beverages that scale easily, under strict hygienic requirements only amplify it. The radiant specification must therefore cover sizing source strength against wall thickness, density and licensing requirements.

Delivery Approach

Delivery was handled as the level range — level solution matched to the actual tank and silo geometry. Execution centred on sizing source strength against wall thickness, density and licensing requirements, together with food-safety and hygienic design per 3-A / EHEDG.

Field Results

Operation shows the benefit clearly — measurable under high temperature, pressure and corrosion without intruding into the vessel, with confidence in this measuring point improving markedly.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · radiant — Application Case

Customer Profile

The typical setting in Chemical & Pharmaceutical is reactors, metering vessels and finished-product tanks. The measuring point is radiant; the focus is non-contact level measurement in extreme duty using radiometric principles.

Key Difficulties

Conditions are highly corrosive media with solvents and crystallisation, partly in explosive atmospheres and, on top of that, corrosion plus Ex protection shortens instrument life and makes downtime costly, which a standard configuration cannot handle for long. The design therefore starts with sizing source strength against wall thickness, density and licensing requirements.

Implementation

The scope ran through the level range: level solution matched to the actual tank and silo geometry. Technically it hinges on sizing source strength against wall thickness, density and licensing requirements, and on these requirements: Ex certification and GMP traceability of records.

Customer Benefit

In practice this means measurable under high temperature, pressure and corrosion without intruding into the vessel, which cut the workload on the site maintenance team.

Power & Energy

Power & Energy · radiant — Application Case

Project Background

The project covers boiler feedwater, turbine condensate and FGD/DeNOx systems. The work centres on radiant and the core task is non-contact level measurement in extreme duty using radiometric principles.

Operating Challenges

The medium and duty are characterised by high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. So radiant cannot be specified generically — it calls for sizing source strength against wall thickness, density and licensing requirements.

Solution

The Ainstru engineering team worked through the level range: level solution matched to the actual tank and silo geometry. The configuration involves sizing source strength against wall thickness, density and licensing requirements, with these requirements in view: compliance with power-industry codes and unit availability targets.

Results

Since start-up the system has run steadily; the practical result is measurable under high temperature, pressure and corrosion without intruding into the vessel.