Technical Data
CompareContinuous / Liquids
| Measuring Principle | |
| Characteristic / Application | Compact transmitter Non-contact measuring technique, for extreme process conditions (temperature, pressure) |
| Interface measurement | Interfaces liquid / liquid also with emulsion layers and interfaces liquid / solid |
| Specialities | Interface, density and mass flow measurement |
| Supply / Communication | AC: 90-253V DC: 18-36V |
| Accuracy | +/-1% |
| Ambient temperature | -40...60°C (-40...140°F), With cooling jacket: 0...120°C (32...248°F) |
| Process temperature | Any |
| Process pressure / max. overpressure limit | Any |
| Main wetted parts | Non-contact |
| Process connection | Non-contact |
| Process connection hygienic | Non-contact |
| Sensor length | PVT scintillator 400mm...2000mm >2000mm cascade mode |
| Max. measurement distance | Unlimited measuring range Cascade |
| Communication | 4...20 mA HART FOUNDATION Fieldbus PROFIBUS PA |
| Certificates / Approvals | ATEX, FM, CSA, IEC Ex, INMETRO, JPN, NEPSI, EAC |
| Safety approvals | SIL1 |
| Components | Isotope: FSG60, FSG61 Source container: FQG60, FQG61, FQG62, FQG63, FQG66 Display: FHX40 Mounting accessories: FHG60 |
Continuous / Solids
| Measuring Principle | |
| Characteristic / Application | Compact transmitter |
| Specialities | Cascading for high silos |
| Supply / Communication | AC: 90-253V DC: 18-36V |
| Accuracy | +/-1% |
| Ambient temperature | -40...60°C (-40...140°F), With cooling jacket: 0...120°C (32...248°F |
| Process temperature | Any |
| Process pressure / max. overpressure limit | Any |
| Main wetted parts | Non-contact |
| Process connection | Non-contact |
| Process connection hygienic | Non-contact |
| Sensor length | PVT scintillator 400mm...2000mm >2000mm cascade mode |
| Max. measurement distance | Unlimited measuring range Cascade |
| Communication | 4...20 mA HART FOUNDATION Fieldbus PROFIBUS PA |
| Certificates / Approvals | ATEX, FM, CSA, IEC Ex, INMETRO, JPN, NEPSI, EAC |
| Safety approvals | SIL1 |
| Components | Isotope: FSG60, FSG61 Source container: FQG60, FQG61, FQG62, FQG63, FQG66 Display: FHX40 Mounting accessories: FHG60 |
Density
| Measuring Principle | |
| Characteristic / Application | Compact transmitter with PT100 input for temperature compensation |
| Supply / Communication | AC: 90-253V DC: 18-36V |
| Ambient temperature | -40°C...50°C / 60°C With cooling jacket: 0°C...120°C |
| Process temperature | Any |
| Process pressure | Any |
| Wetted parts | Non-contact |
| Hygienic | Non-contact |
| Sensor length | NaJ scintillator 50x50mm PVT scintillator 200...400mm |
| Output | 4-20mA HART FOUNDATION Fieldbus PROFIBUS PA |
| Certificates / Approvals | ATEX, FM, CSA, IECEx, TIIS, NEPSI, GOST |
| Components | Isotope: FSG60 Source container: FQG60, FQG61, FQG62, FQG63, QG2000 |
| Other approvals and certificates | SIL1 |
Point Level / Liquids
| Measuring Principle | |
| Characteristic / Application | Compact transmitter |
| Specialities | Interface measurement |
| Supply / Communication | DC: 90-253V AC: 18-36V |
| Ambient temperature | -40...60°C, (-40...140°F), With cooling jacket: 0...120°C (32...248°F) |
| Process temperature | Any |
| Process pressure / max. overpressure limit | Any |
| Min. density of medium | Any |
| Min. conductivity of medium | Any |
| Main wetted parts | Non-contact |
| Process connection | Non-contact |
| Process connection hygienic | Non-contact |
| Sensor length | PVT scintillator 200 mm PVT scintillator 400 mm NaI scintillator 50x50mm |
| Communication | 4-20mA HART FOUNDATION Fieldbus PROFIBUS PA |
| Certificates / Approvals | ATEX, FM, CSA, IEC Ex, INMETRO, JPN, NEPSI, EAC |
| Safety approvals | SIL1/ SIL2 |
| Components | Isotope: FSG60, FSG61 Source container: FQG60, FQG61, FQG62, FQG63, FQG66 |
Point Level / Solids
| Measuring Principle | |
| Characteristic / Application | Compact transmitter |
| Specialities | Optional separate housing |
| Supply / Communication | AC: 90-253V DC: 18-36V |
| Ambient temperature | -40...60°C (-40...140°F), With cooling jacket: 0...120°C (32...248°F) |
| Process temperature | Any |
| Process pressure / max. overpressure limit | Any |
| Min. density of medium | Any |
| Main wetted parts | Non-contact |
| Process connection | Non-contact |
| Process connection hygienic | Non-contact |
| Sensor length | PVT scintillator 200 mm (8") PVT scintillator 400 mm (16") NaJ scintillator 50x50mm (2") |
| Communication | 4...20 mA HART FOUNDATION Fieldbus PROFIBUS PA |
| Certificates / Approvals | ATEX, FM, CSA, IEC Ex, INMETRO, JPN, NEPSI, EAC |
| Safety approvals | SIL1/ SIL2 |
| Components | Isotope: FSG60, FSG61 Source container: FQG60, FQG61, FQG62, FQG63, FQG66 |
The Gammapilot FMG60 compact transmitter is used for non-contact limit detection and continuous level, interface and density measurement of liquids, solids, suspensions and sludge. The variable transmitter is equipped with NaI crystals or plastic scintillators of different lengths, ensuring optimum measurement results in different applications. The transmitter consists of a scintillator, a photomultiplier and an evaluation unit.
Benefits
-
Compact transmitter: one instrument performs all measuring tasks.
-
SIL2/3 certification in accordance with IEC 61508 for limit detection
-
Extremely high availability, reliability and safety even under extreme process and environmental conditions.
-
Extremely high sensitivity and accuracy at the lowest radiation dose (ALARA).
-
Aluminum housing or 316L stainless steel housing (for heavy-duty applications)
-
4-20 mA output for simple plant integration
Applications
-
Suitable for measuring liquids, solids, suspensions or sludge. Can also measure under extreme measuring conditions, e.g. high pressure, high temperature, corrosive, toxic or abrasive media. Suitable for all types of vessels, e.g. reactors, autoclaves, separators, acid tanks, mixers, cyclones and cupola furnaces. Suitable for the food industry without additional requirements or approvals.
-
Temperature: unrestricted (external)
-
Pressure: unrestricted (external)
-
International explosion-protection approval, WHG overflow protection
Spare Parts & Accessories 22
22 spare parts · click to collapse
| Order code | Description | |
|---|---|---|
| 52028420 | *** Stainless Steel CoverMaterial: 316L O-ring 82,22x2,62 Viton Terminal compartment B, Ex d (XP) Gammapilot M | Details |
| 71261143 | *** aluminum coverMaterial: aluminium. O-ring 82.22x2.62 FKM Viton. Terminal compartment B, Ex ia (IS). Usage: FMG60. | Details |
| 52028467 | *** Stainless Steel CoverMaterial: 316L O-ring 82,22x2,62 Viton Terminal compartment A, Ex d (XP) Gammapilot M | Details |
| 71261142 | *** aluminum coverMaterial: aluminium. O-ring 82.22x2.62 FKM Viton. Terminal compartment A, Ex d (XP). Usage: FMG60. | Details |
| 71003008 | Cooling tubewith mounting parts Gammapilot M | Details |
| 71003009 | Cooling tubewith mounting parts Gammapilot M | Details |
| 71002998 | Cooling tubewith mounting parts Gammapilot M | Details |
| 71002999 | Cooling tubewith mounting parts Gammapilot M | Details |
| 71003001 | Cooling tubewith mounting parts Gammapilot M | Details |
| 71003014 | Cooling tubewith mounting parts Gammapilot M | Details |
| 71003005 | Cooling tubeL=50mm with mounting parts Gammapilot M | Details |
| 71071848 | Cooling tube holderConsists of: 2x flat ring 316. 6x hexagon screw M6x20 (FHG65). 6x cylinder head screw M6x20 (FMG60). O-ring 91.67x3.53 FKM. Usage: FHG65, FMG60. | Details |
| 71000221 | Adapter cableConnection service tool RS232(52013675)/ ToF adapter FXA291 (71007843) > Micropilot M, Prosonic M, Levelflex M, Cerabar S, Deltabar S | Details |
| FHX40- | Remote display FHX40remote display + local operation Micropilot M, Prosonic M, Levelflex M, Gammapilot M in Aluminium field housing IP65 NEMA4X. 4-line LC-display. :: menu driven plain text operation :: Easy setup :: User language selectable :: envelope curve display on site | Enquire |
| 71002997 | NaI ray collimatorMounting parts. Usage: FMG60. | Details |
| 71034580 | *** PositionerConsists of: pipe holder DN140. Rod holder. Usage: FHG60. | Details |
| 71034582 | *** PositionerConsists of: pipe holder DN80. Rod holder. Usage: FHG60. | Details |
| 71034584 | *** Positionerconsists of: Pipe holder DN102 Rod holder | Details |
| 71130143 | *** Mounting AccessoriesTension band: 316L. Usage: Mounting FQG60>FMG60 SIL Min. FQG60 + FSG60 0.74MBq, please order separately. | Details |
| 71034581 | *** Probe Support, Pipe Clamp, FHG60 ComponentUsage: FHG60. | Details |
Configurator / Comparison
Source: Endress+Hauserpublic information from the website
Manuals & Documents 12
All documents for this model12 documents · click to expand
操作手册 Gammapilot M FMG60 Chinese
Gammapilot M FMG60 PROFIBUS PA Operating Instructions English
Gammapilot M FMG60 FOUNDATION Fieldbus Operating Instructions English
Gammapilot M FMG60 HART Operating Instructions English
Gammapilot M FMG60 4-20mA HART, PA, FF Description of Instument Functions English
Gammapilot M FMG60 PROFIBUS PA Operating Instructions English
Gammapilot M FMG60 Foundation Fieldbus Operating Instructions English
Gammapilot M FMG60 4-20mA HART Operating Instructions English
Gammapilot M FMG60 4-20mA HART, PA, FF Description of Instument Functions English
TI Gammapilot M FMG60 Chinese
技术资料 放射源源盒QG2000 Chinese
技术资料 放射线源盒QG2000 Chinese
Case Studies
Municipal Wastewater Treatment · radiant — Application Case
Site Conditions
This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was non-contact level measurement in extreme duty using radiometric principles.
The Problem
The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means sizing source strength against wall thickness, density and licensing requirements.
What We Did
We took a level range approach — level solution matched to the actual tank and silo geometry. Delivery was built around sizing source strength against wall thickness, density and licensing requirements, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.
Operating Outcome
In service the system performs as intended — measurable under high temperature, pressure and corrosion without intruding into the vessel, with routine maintenance falling noticeably.
Food & Beverage · radiant — Application Case
Application Context
dosing, pasteurising, filling and CIP stages is a typical Food & Beverage duty. The project started from radiant, focusing on non-contact level measurement in extreme duty using radiometric principles.
Process Constraints
frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, and syrups, dairy and beverages that scale easily, under strict hygienic requirements only amplify it. The radiant specification must therefore cover sizing source strength against wall thickness, density and licensing requirements.
Delivery Approach
Delivery was handled as the level range — level solution matched to the actual tank and silo geometry. Execution centred on sizing source strength against wall thickness, density and licensing requirements, together with food-safety and hygienic design per 3-A / EHEDG.
Field Results
Operation shows the benefit clearly — measurable under high temperature, pressure and corrosion without intruding into the vessel, with confidence in this measuring point improving markedly.
Chemical & Pharmaceutical · radiant — Application Case
Customer Profile
The typical setting in Chemical & Pharmaceutical is reactors, metering vessels and finished-product tanks. The measuring point is radiant; the focus is non-contact level measurement in extreme duty using radiometric principles.
Key Difficulties
Conditions are highly corrosive media with solvents and crystallisation, partly in explosive atmospheres and, on top of that, corrosion plus Ex protection shortens instrument life and makes downtime costly, which a standard configuration cannot handle for long. The design therefore starts with sizing source strength against wall thickness, density and licensing requirements.
Implementation
The scope ran through the level range: level solution matched to the actual tank and silo geometry. Technically it hinges on sizing source strength against wall thickness, density and licensing requirements, and on these requirements: Ex certification and GMP traceability of records.
Customer Benefit
In practice this means measurable under high temperature, pressure and corrosion without intruding into the vessel, which cut the workload on the site maintenance team.
Power & Energy · radiant — Application Case
Project Background
The project covers boiler feedwater, turbine condensate and FGD/DeNOx systems. The work centres on radiant and the core task is non-contact level measurement in extreme duty using radiometric principles.
Operating Challenges
The medium and duty are characterised by high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. So radiant cannot be specified generically — it calls for sizing source strength against wall thickness, density and licensing requirements.
Solution
The Ainstru engineering team worked through the level range: level solution matched to the actual tank and silo geometry. The configuration involves sizing source strength against wall thickness, density and licensing requirements, with these requirements in view: compliance with power-industry codes and unit availability targets.
Results
Since start-up the system has run steadily; the practical result is measurable under high temperature, pressure and corrosion without intruding into the vessel.