Gammapilot FMG50
Technical Data
CompareContinuous / Liquids
| Measuring Principle | Radiometric |
| Characteristic / Application | Compact transmitter for extreme process conditions (temperature, pressure); Non-contact measuring technique |
| Interface measurement | Interfaces liquid / liquid also with emulsion layers Interfaces liquid / solid |
| Specialities | Heartbeat Technology, SIL 2/3 according to IEC 61508, Bluetooth® commissioning, operation and maintenance with the SmartBlue App |
| Supply / Communication | 2-wire loop powered |
| Accuracy | +/-1% |
| Ambient temperature | -40 °C...+80 °C, (-40 °F...+176 °F) |
| Process temperature | Any |
| Process pressure / max. overpressure limit | Any |
| Main wetted parts | Non-contact |
| Process connection | Non-contact |
| Sensor length | PVT scintillator 400 mm...3000 mm, >3000 mm cascade mode |
| Max. measurement distance | Unlimited measuring range, Cascade |
| Communication | 4...20 mA HART |
| Certificates / Approvals | ATEX, IEC Ex, CSA C/US, NEPSI, INMETRO, EAC Ex, JPN Ex, KC Ex |
| Safety approvals | Overfill protection WHG SIL 2/3 |
| Design approvals | EN 10204-3.1 |
| Options | Display |
| Components | Isotope: FSG60, FSG61, Source container: FQG60, FQG61, FQG62, FQG63, FQG66, Mounting accessories: FHG61 |
Continuous / Solids
| Measuring Principle | Radiometric |
| Characteristic / Application | Compact transmitter for extreme process conditions (temperature, pressure); Non-contact measuring technique |
| Specialities | Heartbeat Technology, SIL 2/3 according to IEC 61508, Bluetooth® commissioning, operation and maintenance with the SmartBlue App |
| Supply / Communication | 2-wire loop powered |
| Accuracy | +/-1% |
| Ambient temperature | -40 °C...+80 °C, (-40 °F...+176 °F) |
| Process temperature | Any |
| Process pressure / max. overpressure limit | Any |
| Main wetted parts | Non-contact |
| Process connection | Non-contact |
| Sensor length | PVT scintillator 400 mm...3000 mm, >3000 mm cascade mode |
| Max. measurement distance | Unlimited measuring range, Cascade |
| Communication | 4...20 mA HART |
| Certificates / Approvals | ATEX, IEC Ex, CSA C/US, NEPSI, INMETRO, EAC Ex, JPN Ex, KC Ex |
| Safety approvals | Overfill protection WHG SIL 2/3 |
| Design approvals | EN 10204-3.1 |
| Options | Display |
| Components | Isotope: FSG60, FSG61, Source container: FQG60, FQG61, FQG62, FQG63, FQG66, Mounting accessories: FHG61 |
Density
| Measuring Principle | Radiometric Density |
| Characteristic / Application | Compact transmitter for extreme process conditions (temperature, pressure); Non-contact measuring technique |
| Supply / Communication | 2-wire loop powered |
| Ambient temperature | -40 °C...+80 °C, (-40 °F...+176 °F) |
| Process temperature | Any |
| Process pressure | Any |
| Wetted parts | Non-contact |
| Sensor length | PVT scintillator: 200 mm...400 mm, NAI scintillator: 50 x 50 mm, 50 x 100 mm |
| Output | 4...20 mA HART |
| Certificates / Approvals | ATEX, IEC Ex, CSA C/US, NEPSI, INMETRO, EAC Ex, JPN Ex, KC Ex |
| Options | Display |
| Specialities | Heartbeat Technology, SIL 2/3 according to IEC 61508, Bluetooth® commissioning, operation and maintenance with the SmartBlue App |
| Components | Isotope: FSG60, FSG61, Source container: FQG60, FQG61, FQG62, FQG63, FQG66, Mounting accessories: FHG61 |
Point Level / Liquids
| Measuring Principle | Radiometric Limit |
| Characteristic / Application | Compact transmitter for extreme process conditions (temperature, pressure); Non-contact measuring technique |
| Specialities | Heartbeat Technology, SIL 2/3 according to IEC 61508, Bluetooth® commissioning, operation and maintenance with the SmartBlue App |
| Supply / Communication | 2-wire loop powered |
| Ambient temperature | -40 °C...+80 °C, (-40 °F...+176 °F) |
| Process temperature | Any |
| Process pressure / max. overpressure limit | Any |
| Main wetted parts | Non-contact |
| Process connection | Non-contact |
| Sensor length | PVT scintillator: 200 mm...400 mm, NAI scintillator: 50 x 50 mm, 50 x 100 mm |
| Communication | 4...20 mA HART |
| Certificates / Approvals | ATEX, IEC Ex, CSA C/US, NEPSI, INMETRO, EAC Ex, JPN Ex, KC Ex |
| Safety approvals | Overfill protection WHG SIL 2/3 |
| Design approvals | EN 10204-3.1 |
| Options | Display |
| Components | Isotope: FSG60, FSG61, Source container: FQG60, FQG61, FQG62, FQG63, FQG66, Mounting accessories: FHG61 |
Point Level / Solids
| Measuring Principle | Radiometric Limit |
| Characteristic / Application | Compact transmitter for extreme process conditions (temperature, pressure); Non-contact measuring technique |
| Specialities | Heartbeat Technology, SIL 2/3 according to IEC 61508, Bluetooth® commissioning, operation and maintenance with the SmartBlue App |
| Supply / Communication | 2-wire loop powered |
| Ambient temperature | -40 °C...+80 °C, (-40 °F...+176 °F) |
| Process temperature | Any |
| Process pressure / max. overpressure limit | Any |
| Main wetted parts | Non-contact |
| Process connection | Non-contact |
| Sensor length | PVT scintillator: 200 mm...400 mm, NAI scintillator: 50 x 50 mm, 50 x 100 mm |
| Communication | 4...20 mA HART |
| Certificates / Approvals | ATEX, IEC Ex, CSA C/US, NEPSI, INMETRO, EAC Ex, JPN Ex, KC Ex |
| Safety approvals | Overfill protection WHG SIL 2/3 |
| Design approvals | EN 10204-3.1 |
| Options | Display |
| Components | Isotope: FSG60, FSG61, Source container: FQG60, FQG61, FQG62, FQG63, FQG66, Mounting accessories: FHG61 |
The Gammapilot FMG50 compact transmitter performs non-contact limit detection, continuous level measurement, interface measurement and density measurement in liquids, solids, suspensions or sludge. It is the first two-wire loop-powered compact transmitter, minimizing design and installation workload.
Benefits
A true two-wire loop-powered compact transmitter that minimizes design and installation workload
The first two-wire loop-powered compact transmitter, saving installation and design costs
Increased safety, efficiency and stability even under extreme process and environmental conditions
Designed in accordance with IEC 61508, fully meeting the measurement requirements of SIL2/3 applications
Advanced Heartbeat Technology reduces verification workload and minimizes device downtime
Innovative sensor technology for ambient temperatures up to +80°C (+176°F) without cooling
Bluetooth® wireless technology for remote operation outside the beam radiation range
Applications
Suitable for all types of process vessels, e.g. reactors, autoclaves, separation tanks, acid tanks, cyclones
Suitable for measuring media such as liquids, solids, suspensions or sludge
Suitable for extreme conditions, e.g. corrosive, abrasive, viscous or toxic media
Process temperature: unrestricted (non-contact measurement)
Process pressure: unrestricted (non-contact measurement)
Housing materials: 316L, aluminum
International explosion-protection approval, SIL certification and WHG overflow protection
E+H Product Model Configuration Tool
Please enter the product model to configure
Product comparison
Please enter the product models to compare in the fields below; up to three products can be compared
Technical documentation
Technical data
Documents/Manuals/Software
Accessories/Spare parts
Source: Endress+Hauserpublic information from the website
Case Studies
Municipal Wastewater Treatment — Wastewater Treatment Plant · Radiometric Application Case
Project Background
Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Radiometric.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Radiometric for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage — Food Production Line · Radiometric Application Case
Project Background
Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Radiometric.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Radiometric for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical — Reactors and Storage Tanks · Radiometric Application Case
Project Background
Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Radiometric.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Radiometric for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy — Power Plant Boiler and Turbine · Radiometric Application Case
Project Background
Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Radiometric.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Radiometric for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Related Products
Endress+HauserSource container FQG62
Endress+HauserGamma source FSG61, Co60
Endress+HauserSource container FQG66
Endress+HauserGamma source FSG60, Cs137
Endress+HauserGammapilot M FMG60
Endress+HauserSource container FQG63
Endress+HauserSource container FQG60
Endress+Hauser