Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

FQG74 Source container

FQG74 Source container
Source container
Product details for the source container FQG74. Radiometric level and density source container for demanding applications.
Compare

Continuous / Liquids

Measuring Principle Radiometric
Characteristic / Application Source container with flexible extension element to position up to 20 sources inside the process vessel (diptube)
Weight: 800 kg
Specialities With flexible extension elements
Ambient temperature -52°C...+120°C,
(-61°F...+248°F)
Process temperature -52°C...+450°C
(-61°F...+842°F)
Process pressure / max. overpressure limit Any
Main wetted parts Non-contact
Process connection Non-contact

Continuous / Solids

Measuring Principle Radiometric
Characteristic / Application Source container with flexible extension element to position up to 20 sources inside the process vessel (diptube)
Weight: 800 kg
Specialities With flexible extension elements
Ambient temperature -52°C...+120°C,
(-61°F...+248°F)
Process temperature -52°C...+450°C
(-61°F...+842°F)
Process pressure / max. overpressure limit Any
Main wetted parts Non-contact
Process connection Non-contact

Density

Measuring Principle Radiometric Density
Characteristic / Application Source container with flexible extension element to position up to 20 sources inside the process vessel (diptube)
Weight: 800 kg
Ambient temperature -52°C.…+120°C
(-61°F.…+248°F)
Process temperature -52°C.…+450°C
(-61°F.…+842°F)
Process pressure Any
Wetted parts Non-contact
Specialities With flexible extension elements
Wetted materials Non-contact
Measured variables Density
Max. process pressure Any

Point Level / Liquids

Measuring Principle Radiometric Limit
Characteristic / Application Source container with flexible extension element to position up to 20 sources inside the process vessel (diptube)
Weight: 800 kg
Specialities With flexible extension elements
Ambient temperature -52°C...+120°C,
(-61°F...+248°F)
Process temperature -52°C...+450°C
(-61°F...+842°F)
Process pressure / max. overpressure limit Any
Main wetted parts Non-contact
Process connection Non-contact

Point Level / Solids

Measuring Principle Radiometric Limit
Characteristic / Application Source container with flexible extension element to position up to 20 sources inside the process vessel (diptube)
Weight: 800 kg
Specialities With flexible extension elements
Ambient temperature -52°C...+120°C,
(-61°F...+248°F)
Process temperature -52°C...+450°C
(-61°F...+842°F)
Process pressure / max. overpressure limit Any
Main wetted parts Non-contact
Process connection Non-contact

FQG74, source container for radiometric level and density measurement that works reliably, is robust and easy to use, and can hold up to 20 radiation sources

Advantages

  • High safety (complies with Type A packaging requirements), high radiation protection rating

  • Easy commissioning of the radiation source; the source position inside the container can be adjusted individually via a separate cable (max. cable length 30 m)

  • Simplified safety measures, no controlled area required

  • Various container versions available to flexibly meet the requirements of different operating conditions

  • The switch position of the container can be securely locked with a padlock to prevent theft

Field of application

The FQG74 source container can hold up to 20 high-activity radiation sources during radiometric measurement. The container is robust, has a high radiation protection rating and can be easily installed on straight or angled tubes.

The FQG74 source container is used together with radiation detectors and is suitable for tasks such as limit detection, continuous level and density measurement. Suitable for large measuring range applications.

Oil and gas

  • Multi-point density measurement in the oil-water separation process

  • Level control of the catalyst bed in reactors during the hydrocracking process

Petrochemical/chemical

  • Level or multi-point density measurement of process reactors in PTA and urea production

 

Spare Parts & Accessories 10

10 spare parts · click to collapse
Order codeDescription
71677015Sealing Set FQG74Consists of: 1x o-ring for hood, D299x6, FKM, 1x o-ring for transportation lock, D113x6, FKM, 1x o-ring for shutter, D76x6, FKM. Usage: FQG74.Details
71676920Eyelet connection M16x24, 4 pcs.360° rotatable, 230° pivotable. Colour: pink. Usage: FQG74.Details
71677022Sight glass, in hood Rd125x15DIN7080-10 D125x15. Material: borosilicate glass. Usage: FQG74.Details
71695989Sight glass shutter, sealMaterials Housing: Stainless steel 1.4305, Window: ESG glas, Flat seal: FVMQ. Usage: FQG74.Details
71676925Cranked handle incl. Screw M8x30Consists of: Cranked handle manufacturer Ganter Norm, GN269-100-V12, Cylinder head screw ISO4762 - M8x30. Usage: FQG74.Details
71677014Transportation lock, weldedTransportation lock with hexagon screw ISO4014 - M16. Usage: FQG74.Details
71677019Hood, welded, with sight glassMaterial: 316L. Usage: FQG74.Details
71677023Welded safety sourceMaterial: 316L. Usage: FQG74.Details
XPF0018-Flexible extension cableUsage: FQG63, FQG74.Enquire
FHG74Accessory source container FHG74Accessory for Source container FQG74. 3 different adapters are available for 3 different applications. Usage: FQG74.Enquire

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

 

Source:Endress+Hauserpublic information from the website

All documents for this model
6 documents · click to expand
BA

BA 源盒FQG74 Chinese

Rev. 0324 80 pages
Preview
BA

BA 源盒FQG74 Chinese

Rev. 0224 76 pages
Preview
BA

BA Source container FQG74 Lowerable source magazine English

Rev. 0324 88 pages
Preview
BA

BA Source container FQG74 Source container with up to 20 radiation sources English

Rev. 0224 84 pages
Preview
TI

TI 源盒FQG74 Chinese

Rev. 0424 24 pages
Preview
TI

TI Source Container FQG74 English

Rev. 0626 28 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · radiant — Application Case

Site Conditions

This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was non-contact level measurement in extreme duty using radiometric principles.

The Problem

The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means sizing source strength against wall thickness, density and licensing requirements.

What We Did

We took a level range approach — level solution matched to the actual tank and silo geometry. Delivery was built around sizing source strength against wall thickness, density and licensing requirements, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.

Operating Outcome

In service the system performs as intended — measurable under high temperature, pressure and corrosion without intruding into the vessel, with routine maintenance falling noticeably.

Food & Beverage

Food & Beverage · radiant — Application Case

Application Context

dosing, pasteurising, filling and CIP stages is a typical Food & Beverage duty. The project started from radiant, focusing on non-contact level measurement in extreme duty using radiometric principles.

Process Constraints

frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, and syrups, dairy and beverages that scale easily, under strict hygienic requirements only amplify it. The radiant specification must therefore cover sizing source strength against wall thickness, density and licensing requirements.

Delivery Approach

Delivery was handled as the level range — level solution matched to the actual tank and silo geometry. Execution centred on sizing source strength against wall thickness, density and licensing requirements, together with food-safety and hygienic design per 3-A / EHEDG.

Field Results

Operation shows the benefit clearly — measurable under high temperature, pressure and corrosion without intruding into the vessel, with confidence in this measuring point improving markedly.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · radiant — Application Case

Customer Profile

The typical setting in Chemical & Pharmaceutical is reactors, metering vessels and finished-product tanks. The measuring point is radiant; the focus is non-contact level measurement in extreme duty using radiometric principles.

Key Difficulties

Conditions are highly corrosive media with solvents and crystallisation, partly in explosive atmospheres and, on top of that, corrosion plus Ex protection shortens instrument life and makes downtime costly, which a standard configuration cannot handle for long. The design therefore starts with sizing source strength against wall thickness, density and licensing requirements.

Implementation

The scope ran through the level range: level solution matched to the actual tank and silo geometry. Technically it hinges on sizing source strength against wall thickness, density and licensing requirements, and on these requirements: Ex certification and GMP traceability of records.

Customer Benefit

In practice this means measurable under high temperature, pressure and corrosion without intruding into the vessel, which cut the workload on the site maintenance team.

Power & Energy

Power & Energy · radiant — Application Case

Project Background

The project covers boiler feedwater, turbine condensate and FGD/DeNOx systems. The work centres on radiant and the core task is non-contact level measurement in extreme duty using radiometric principles.

Operating Challenges

The medium and duty are characterised by high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. So radiant cannot be specified generically — it calls for sizing source strength against wall thickness, density and licensing requirements.

Solution

The Ainstru engineering team worked through the level range: level solution matched to the actual tank and silo geometry. The configuration involves sizing source strength against wall thickness, density and licensing requirements, with these requirements in view: compliance with power-industry codes and unit availability targets.

Results

Since start-up the system has run steadily; the practical result is measurable under high temperature, pressure and corrosion without intruding into the vessel.