Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

FQR16 Soliwave

FQR16 Soliwave
Soliwave FQR16
Ultra-compact transceiver for non-contact point level detection of bulk solids and liquids, as well as piece goods counting and object detection. The Soliwave FQR16 is used together with the FDR16.
Compare

Point Level / Solids

Measuring Principle Microwave barrier
Characteristic / Application Microwave barrier
Non-contact point level detection
(min/max, e.g. full and empty detection for overflow
and dry run protection) for all types of bulk solids
(from powdery to lumpy) and liquids, also in potentially
explosive atmospheres (dust Ex).
Detection, counting, and positioning of objects
Object detection on conveyor belts
Specialities Detection range: max. 20 m
Supply / Communication 18 V ... 30 V DC,
Plug M12
Ambient temperature -20°C ... +60°C (-4°F ... +140°F)
Process temperature Non-contact installation: any
Within installation:
-20°C ... +60°C (-4°F ...+140°F)
With high temperature adapter:
up to +450°C (+842°F)
Process pressure / max. overpressure limit Non-contact installation: any
Within installation:
0.5 bar ... 6.8 bar (7.2 psi ... 99 psi) abs.
With high pressure adapter:
up to +21 bar (+305 psi) abs.
Min. density of medium Solid weight: > 10 g/l
Main wetted parts Non-contact installation:
no wetted parts
Contact installation:
316L, PTFE
Process connection ISO228-1: G1", G1-1/2"
ASME: NPT1-1/2"
Process connection hygienic Non-contact installation
Communication 3-wire-DC-PNP,
2 DC-PNP-outputs
Certificates / Approvals ATEX, IEC Ex
Design approvals EN10204-3.1
Hygienic approvals EG1935/2004
Options Mounting bracket
Counternut
Welding sleeve
Connection cable
Connecting cable
High-pressure adapter
High-temperature adapter
Extension for HT adapter
Mounting flange
Sight glass fitting
FAR50, FAR51, FAR52, FAR54
Components FDR16
Application limits Solid weight: < 10 g/l

Soliwave FDR16 is an ultra-compact microwave level barrier for non-contact limit detection, piece counting and object detection. Soliwave FDR16 is used together with FQR16 as a pair. The microwave level barrier uses a non-contact detection method and can be installed in hard-to-access positions or confined spaces. It can measure through the wall of non-metallic tanks.

Benefits
Non-contact measuring principle — process properties do not interfere with the detection process

  • High safety — with permanent self-diagnostics and comprehensive self-test functions

  • The first microwave level barrier with IP69 degree of protection

  • Complies with the requirements of EU Regulation 1935/2004

  • Easy commissioning and excellent price-performance ratio

  • Safe detection —— non-contact measuring method, wear-free, maintenance-free, continuous operation

  • Robust and durable —— stainless steel housing

Application
The microwave level barriers Soliwave FDR16 and FQR16 are used for low and high limit detection of powdered solids, pasty solids and liquids, for example tank overflow protection and pump dry-run protection. The instruments can also be used for piece counting and object detection. They meet the requirements of various industries and are widely used, for example in the primary raw materials, energy and food industries. 
 

 

Spare Parts & Accessories 65

65 spare parts · click to collapse
Order codeDescription
71530949Connection cable socket M12A, 5m, PURConnecting cable M12A, 5m, 4-pole, Right angle socket. Material: PUR. Usage: FDR16, FQR16, FTR16.Details
71530950Connection cable socket M12A, 10m, PURConnecting cable M12A, 10m, 4-pole, Right angle socket. Material: PUR. Usage: FDR16, FQR16, FTR16.Details
71530952Connecting cable M12A, 20m, PURConnecting cable socket M12A, 20m, 4-pole, Right angle socket. Material: PUR. Usage: FDR16, FQR16, FTR16.Details
71530971Connection cable socket M12A, Ex, 5 m, PURConnecting cable M12A, 5m, 4-pole, Right angle socket. Material: PUR. Usage: in Ex area. Usage: FDR16, FQR16, FTR16.Details
71530973Connection cable socket M12A, Ex, 10 m, PURConnecting cable M12A, 10m, 4-pole, Right angle socket. Material: PUR. Usage: in Ex area. Usage: FDR16, FQR16, FTR16.Details
71530943Connecting cable M12A, 5m, PURConnecting cable M12A, 5m, 4-pole, Right angle socket/right angle plug. Material: PUR. Usage: FDR16, FQR16, FTR16.Details
71530944Connecting cable M12A, 10m, PURConnecting cable M12A, 10m, 4-pole, Right angle socket/right angle plug. Material: PUR. Usage: FDR16, FQR16, FTR16.Details
71530945Connecting cable M12A, 25m, PURConnecting cable M12A, 20m, 4-pole, Right angle socket/right angle plug. Material: PUR. Usage: FDR16, FQR16, FTR16.Details
71530969Connecting cable M12A, Ex, 5m, PURConnecting cable M12A, 5m, 4-pole, Right angle socket/right angle plug. Material: PUR. Usage: in Ex area. Usage: FDR16, FQR16, FTR16.Details
71530970Connecting cable M12A, Ex, 10m, PURConnecting cable M12A, 10m, 4-pole, Right angle socket/right angle plug. Material: PUR. Usage: in Ex area. Usage: FDR16, FQR16, FTR16.Details
71381884Flange DN40 PN40, G1-1/2, 316TiUsage: FDR56/FDR57, FQR56/FQR57, FTR20.Details
71381885Flange DN40 PN40, G1-1/2, 316Ti, 3.1Usage: FDR56/FDR57, FQR56/FQR57, FTR20.Details
71530977Flange DN40 PN40, G1, 316TiFlange DN40 PN40 according to EN1092-1 for process connection G1 According to ISO228-1. Material: stainless steel 316Ti. Usage: FDR16, FQR16, FTR16.Details
71530992Flange DN40 PN40, G1, 316Ti, 3.1Flange DN40 PN40 according to EN1092-1 for process connection G1 According to ISO228-1. Inspection certificate 3.1 According to EN10204. Material: stainless steel 316Ti. Usage: FDR16, FQR16, FTR16.Details
71381887Flange DN50 PN16, G1-1/2, 316TiUsage: FDR56/FDR57, FQR56/FQR57, FTR20.Details
71381888Flange DN50 PN16, G1-1/2, 316Ti, 3.1Usage: FDR56/FDR57, FQR56/FQR57, FTR20.Details
71531009Flange DN50 PN16, G1, 316TiFlange DN50 PN16 according to EN1092-1 for process connection G1 According to ISO228-1. Material: stainless steel 316Ti. Usage: FDR16, FQR16, FTR16.Details
71531011Flange DN50 PN16, G1, 316Ti, 3.1Flange DN50 PN16 according to EN1092-1 for process connection G1 According to ISO228-1. Inspection certificate 3.1 According to EN10204. Material: stainless steel 316Ti. Usage: FDR16, FQR16, FTR16.Details
71381890Flange DN100 PN16, G1-1/2, 316TiUsage: FDR56/FDR57, FQR56/FQR57, FTR20.Details
71381891Flange DN100 PN16, G1-1/2, 316Ti, 3.1Usage: FDR56/FDR57, FQR56/FQR57, FTR20.Details

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

Accessories / Spare parts

 

Source: Endress+Hauser public website information

All documents for this model
3 documents · click to expand
BA

Soliwave FDR16/FQR16 Operating Instructions English

Rev. 0322 40 pages
Preview
TI

TI Accessory FAR52 English

Rev. 0325 8 pages
Preview
TI

TI Soliwave FDR16/FQR16 English

Rev. 0322 36 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · microwave limit — Application Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted microwave limit properly configured on the existing plant, with the aim of microwave point-level detection for solids or liquids.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the microwave limit configuration has to involve choosing contacting or non-contacting by stickiness and mounting position.

Configuration

Supply and installation were organised through the level range: level solution matched to the actual tank and silo geometry. On site this meant choosing contacting or non-contacting by stickiness and mounting position, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is build-up does not affect switching, keeping point detection dependable, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · microwave limit — Application Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was microwave point-level detection for solids or liquids.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means choosing contacting or non-contacting by stickiness and mounting position.

What We Did

We took a level range approach — level solution matched to the actual tank and silo geometry. Delivery was built around choosing contacting or non-contacting by stickiness and mounting position, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — build-up does not affect switching, keeping point detection dependable, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · microwave limit — Application Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from microwave limit, focusing on microwave point-level detection for solids or liquids.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The microwave limit specification must therefore cover choosing contacting or non-contacting by stickiness and mounting position.

Delivery Approach

Delivery was handled as the level range — level solution matched to the actual tank and silo geometry. Execution centred on choosing contacting or non-contacting by stickiness and mounting position, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — build-up does not affect switching, keeping point detection dependable, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · microwave limit — Application Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is microwave limit; the focus is microwave point-level detection for solids or liquids.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with choosing contacting or non-contacting by stickiness and mounting position.

Implementation

The scope ran through the level range: level solution matched to the actual tank and silo geometry. Technically it hinges on choosing contacting or non-contacting by stickiness and mounting position, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means build-up does not affect switching, keeping point detection dependable, which cut the workload on the site maintenance team.