Order Code:FTR525-1020/0
Corresponding ext. order code:FTR525-BA21
Name:Nivotester FTR525
Configuration
| Code | Name | Order | Specification |
|---|---|---|---|
| 010 | Approval | BA | ATEX II (1)G [Ex ia Ga] IIC ATEX II (1)D [Ex ia Da] IIIC |
| 020 | Output | 2 | 2x relay SPDT, 4-20mA |
| 070 | Application | 1 | Point level |
Configuration Explained
This is an FTR525 process transmitter, for the 57 series, with dual ATEX gas and dust intrinsically safe approval, accepts hazardous area sensors for point level detection, outputs 2 SPDT relays plus 4-20mA, separate alarms for high and low level, the relay interlocks the conveyor directly, simple wiring and fast commissioning, easy to use on site and simple to maintain later, suitable for point level control in hazardous area silos.