Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

LIQUILINE Liquiline Edge Module CYY7

LIQUILINE Liquiline Edge Module CYY7
Liquiline Edge Module CYY7
Endress+Hauser LIQUILINE
Liquiline Edge Module CYY7 for all industries and their utility applications, built into Liquiline platform products: Liquiline transmitters (CM442, CM442R, CM444, CM444R, CM448, CM448R); Liquiline analyzers (CA80AL aluminum analyzer, CA80AM ammonium analyzer, CA80COD chemical oxygen demand analyzer, CA80CR chromium analyzer, CA80FE iron analyzer, CA80HA hardness analyzer, CA80NO nitrite analyzer, CA80PH orthophosphate analyzer, CA80SI silicate analyzer, CA80TN total nitrogen analyzer, CA80TP total phosphorus analyzer); Liquistation fully automatic water samplers (CSF34, CSF48).

The Liquiline Edge Module CYY7 is suitable for all industries and their utility applications and is built into Liquiline platform products:

 

Advantages

  • Connect to the Netilion cloud platform:The device continuously uploads data from the measuring point to the Netilion IIoT cloud ecosystem. It supports remote data access and query, makes full use of the data and serves IIoT applications.

  • Save time and costs:Unlock data in the Netilion cloud platform and empower the field: view data overviews anytime, anywhere, monitor device health and simplify maintenance work, for example by receiving alarm messages for critical parameters.

  • Simple installation, seamless integration:Plug-and-play, saves installation space, and no need to consider the existing system architecture and fieldbus type. It has an intuitive operating wizard that simplifies device commissioning.

  • Cybersecurity:The Liquiline Edge Module CYY7 complies with high security standards and keeps data safe at all times. It is based on a unique security concept that avoids process interruptions.

  • Netilion Liquiline Assist:Clear visualization interface, sensor health status and overview interface help users make full use of the collected data.

  • Order as needed:It can be selected as a function option when ordering a new transmitter, as an upgrade option for existing Liquiline platform products (transmitters, samplers or analyzers), and flexibly as a radio version or Ethernet version.

 

Field of application

With the Liquiline Edge Module CYY7 wireless connectivity, large amounts of data can be uploaded from the measuring point (even from hard-to-access locations) to the Netilion cloud ecosystem. It supports remote querying of measured values, provides additional process information, serves IIoT applications and effectively simplifies maintenance work. The module is plug-and-play and easy to use, with no need to consider the existing system architecture and fieldbus type.

 

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

Accessories/Spare parts

 

 

Source:Endress+Hauserpublic information from the website

Municipal Wastewater Treatment

Municipal Wastewater Treatment · data manager — Application Case

Site Conditions

This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was centralised data acquisition, storage and forwarding to management platforms.

The Problem

The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means selected by channel count, storage depth and forwarding protocol.

What We Did

We took a system components range approach — supplying as a full cabinet and signal-chain configuration. Delivery was built around selected by channel count, storage depth and forwarding protocol, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.

Operating Outcome

In service the system performs as intended — automatic backfill after outages, greatly improving data completeness, with routine maintenance falling noticeably.

Food & Beverage

Food & Beverage · data manager — Application Case

Application Context

dosing, pasteurising, filling and CIP stages is a typical Food & Beverage duty. The project started from data manager, focusing on centralised data acquisition, storage and forwarding to management platforms.

Process Constraints

frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, and syrups, dairy and beverages that scale easily, under strict hygienic requirements only amplify it. The data manager specification must therefore cover selected by channel count, storage depth and forwarding protocol.

Delivery Approach

Delivery was handled as the system components range — supplying as a full cabinet and signal-chain configuration. Execution centred on selected by channel count, storage depth and forwarding protocol, together with food-safety and hygienic design per 3-A / EHEDG.

Field Results

Operation shows the benefit clearly — automatic backfill after outages, greatly improving data completeness, with confidence in this measuring point improving markedly.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · data manager — Application Case

Customer Profile

The typical setting in Chemical & Pharmaceutical is reactors, metering vessels and finished-product tanks. The measuring point is data manager; the focus is centralised data acquisition, storage and forwarding to management platforms.

Key Difficulties

Conditions are highly corrosive media with solvents and crystallisation, partly in explosive atmospheres and, on top of that, corrosion plus Ex protection shortens instrument life and makes downtime costly, which a standard configuration cannot handle for long. The design therefore starts with selected by channel count, storage depth and forwarding protocol.

Implementation

The scope ran through the system components range: supplying as a full cabinet and signal-chain configuration. Technically it hinges on selected by channel count, storage depth and forwarding protocol, and on these requirements: Ex certification and GMP traceability of records.

Customer Benefit

In practice this means automatic backfill after outages, greatly improving data completeness, which cut the workload on the site maintenance team.

Power & Energy

Power & Energy · data manager — Application Case

Project Background

The project covers boiler feedwater, turbine condensate and FGD/DeNOx systems. The work centres on data manager and the core task is centralised data acquisition, storage and forwarding to management platforms.

Operating Challenges

The medium and duty are characterised by high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. So data manager cannot be specified generically — it calls for selected by channel count, storage depth and forwarding protocol.

Solution

The Ainstru engineering team worked through the system components range: supplying as a full cabinet and signal-chain configuration. The configuration involves selected by channel count, storage depth and forwarding protocol, with these requirements in view: compliance with power-industry codes and unit availability targets.

Results

Since start-up the system has run steadily; the practical result is automatic backfill after outages, greatly improving data completeness.