Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

iTHERM ModuLine TM131

iTHERM ModuLine TM131
Product family: iTHERM ModuLine TM131
iTHERM ModuLine TM131
Endress+Hauser TM131-NACDHBB2BA5CBAB3AA1DA1
iTHERM ModuLine TM131;Approval NEPSI Ex ia IIC T1...T6 Ga/Gb, Ex ia IIIC T85oC...T450oC Db;Thermowell Thermometer with thermowell, hex, similar to DIN43772 Form 5, 8;Thermometer Design Removeable neck

Order Code:TM131-NACDHBB2BA5CBAB3AA1DA1

Name:iTHERM ModuLine TM131

Configuration

CodeNameOrderSpecification
010ApprovalNANEPSI Ex ia IIC T1...T6 Ga/Gb, Ex ia IIIC T85oC...T450oC Db
020ThermowellCThermometer with thermowell, hex, similar to DIN43772 Form 5, 8
030Thermometer DesignDRemoveable neck D11mm acc. to DIN43772
050Process/Thermowell Connection; MaterialHBG1/2 male thread compression fitting; 316L, ferrule 316L
060Thermowell Diameter; MaterialB211x2mm; 316L
070Tip ShapeBStraight (DIN 43772 form 2/2G/2F)
080Immersion Length UA5120 mm
090Removable Neck Length EC80 mm
100Lagging Length TBPredefined by design
110Sensor Type; Measuring Range; MaterialA1x Pt100 TF; -50...+400oC; 316L
130Sensor Standard; ClassificationBIEC60751; class A, 3-wire
140Electrical Connection3A4-20mA HART, 1-channel TMT72, head transmitter DIN B
150Terminal Head;Material;Protection ClassA1TA30A comfort flip cover; Alu; IP66/68
170Cable Entry Terminal HeadD2x M20x1.5 female thread
480Device ModelA11

Configuration Explained

This is a TM131 modular temperature transmitter, with NEPSI intrinsically safe approval and CCC marking, can be installed in hazardous areas, thermowell with hexagonal extension per DIN43772 Form 5/8, detachable neck D11, G1/2 adjustable compression fitting 316L, thermowell 11x2 mm, 120 mm insertion depth, 80 mm neck length, one Pt100 thin-film element, three-wire, class A, -50 to 400 °C, with TMT72 transmitter, 4-20 mA HART, TA30A housing IP66/68, suitable for intrinsically safe loops in chemical plants.

25 models · click to collapse