Temperature transmitters

Measuring Principle Field transmitter
Input 1 x RTD, TC, Ohm, mV
Output 1 x analog 4...20 mA / HART
Auxiliary power supply 11…36 V DC (standard-version)
11...30 V DC (Ex ia)
Communication HART-protocol
Bluetooth® wireless technology
Installation in field
Accuracy (Pt100, -50...200 °C) <=0,1 K
(Pt100, -58...392 °F) <=0,18 °F
Galvanic isolation yes
Certification ATEX Ex ia, Ex ic, Ex tc, Ex nA, Ex db, Ex tb
ATEX IECEx Ex ia, Ex tb, Ex db
IECEx Ex d, Ex tb
CSA C/US General Purpose
CSA C/US IS, NI, XP, DIP
INMETRO Ex ia, Ex d, Ex tb
NEPSI Ex ia, Ex d
EAC Ex ia, Ex d
UKCA Ex ia, Ex ic, Ex tb, Ex tc, Ex nA, Ex db
JPN Ex d, Ex tb
PESO Ex ia
IND Ex ia
KC

The single-channel iTEMP TMT142B temperature transmitter with backlit display delivers reliable, precise and long-term-stable measuring results under demanding conditions and in hazardous areas. It features a Bluetooth® interface for secure remote operation (Endress+Hauser SmartBlue app) and is equipped with a robust single-compartment field housing. It connects RTD, thermocouple (TC), resistance (Ω) or voltage (mV) signals and converts them into a 4...20 mA signal with HART® 7 communication.

Advantages

  • Numerous international approvals permit use in hazardous areas:

  • CSA (IS, NI, XP and DIP) and ATEX (Ex ia, Ex d and dust explosion protection)

  • Pressure-tight single-compartment housing with integrated overvoltage protection for reliable, long-term, stable and precise temperature measurement even under demanding conditions

  • Bluetooth® interface: use the Endress+Hauser SmartBlue app to save time and effort on instrument commissioning, configuration and maintenance

  • Advanced diagnostics and condensed status notifications support preventive maintenance in accordance with NAMUR NE107

  • Newly developed large-digit backlit display clearly shows process information under all environmental conditions

Application areas

  • Temperature transmitter supporting secure Bluetooth® and HART® 7 communication

  • Backlit display for clear on-site display of process and diagnostic information

  • Universal input signals for connecting RTD, thermocouple, resistance and voltage signals

  • High reliability, high long-term stability and high measuring accuracy for safe use under demanding conditions

  • Robust aluminum or stainless steel housing for safe use in hazardous areas or under demanding conditions

Spare Parts & Accessories 23

23 spare parts · click to collapse
Order codeDescription
TMT142X-Spare Part TMT142XSpare parts TMT142XEnquire
TMT142E-Electronic module TMT142EAttention: Only 1 piece per position orderable in offer/order because of item category group ZTA1.Enquire
TMT142X-Spare Part TMT142XSpare parts TMT142XEnquire
71158816O-ringDetails
71502617O-ring 88x3 HNBR 70° Shore PTFE_5pcsPacking unit: 5 piecesDetails
TMT142G-Housing TMT142GHousing TMT142GEnquire
71386275Integrable Surge Arrester ModuleFor subsequent mounting in field transmitter. Ensure compatibility.Details
51004948front cover latch pinScrew, washer, spring washerDetails
51006845cable glandCable gland NPT 1/2, D4-8.5, IP68Details
71638066Cable gland M20x1.5 ATEX/IECExDetails
510043871/2 NPT to M20x1.5 adapterAdapter M20x1,5/NPT1/2" cable entryDetails
51004915M24x1.5 to M20x1.5 adapterAdapter M20x1.5 exter./M24x1.5 intern.VADetails
71502941O-Ring 18.77x1.78 HNBR 70° Shore PTFEPacking unit: 10 piecesDetails
51004490blind coverDetails
51006888blind coverDetails
71525620Blind plug M20x1.5 Ex-d + O-ring, aluminiumDetails
71525621Blind plug G1/2 Ex-d + o-ring, AluDetails
71525622Blind plug M20x1.5 Ex-d + O-ring V4ADetails
71525623Blind plug G1/2 Ex-d + O-ring V4ADetails
51516983Communication interface FXA291Serial USB Computer Interface Technical Data: - USB Version1.1 or higher - Power supply via USB - IP51; NEMA/Typ 3 - Ambient temperature: -20....+60oC - Ex: II(2) G (EEx ia) II C - ATEX: BVS 05 ATEX E 095 Scope of deliovery: Commubox FXA 291 MS Windows USB driver Device is submitted for CSA/FM application. The device may not be modified and may be used with intrinsically safe circuits with corresponding characteristics only (see safety certificate).Details

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

Accessories / Spare parts

Source:Endress+Hauserpublic information from the website

All documents for this model
9 documents · click to expand
BA

BA iTEMP TMT142B Chinese

Rev. 1623 100 pages
Preview
BA

BA iTEMP TMT142B English

Rev. 1623 100 pages
Preview
BA

Operating instructions Temperature field transmitter iTEMP® HART® TMT142 English

HART 136 pages
Preview
TI

iTEMP TMT142B Chinese

Rev. 1621 24 pages
Preview
TI

温度变送器 Chinese

Rev. 1312 16 pages
Preview
TI

通用型温度变送器 Chinese

Rev. 0107 12 pages
Preview
TI

iTEMP TMT142B English

Rev. 1621 24 pages
Preview
TI

Technical Information iTEMP® HART® TMT142 English

HART Rev. 1312 14 pages
Preview
TI

Technical Information Temperature field transmitter iTEMP® HART® TMT142 English

HART 16 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Temperature transmitter — Application Case

Site Conditions

This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was converting RTD or thermocouple signals into a standard current output.

The Problem

The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means choosing integral or remote versions by ambient, Ex zone and mounting.

What We Did

We took a temperature range approach — temperature solution matched to measuring point and response needs. Delivery was built around choosing integral or remote versions by ambient, Ex zone and mounting, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.

Operating Outcome

In service the system performs as intended — better noise immunity and much smaller transmission error, with routine maintenance falling noticeably.

Food & Beverage

Food & Beverage · Temperature transmitter — Application Case

Application Context

dosing, pasteurising, filling and CIP stages is a typical Food & Beverage duty. The project started from Temperature transmitter, focusing on converting RTD or thermocouple signals into a standard current output.

Process Constraints

frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, and syrups, dairy and beverages that scale easily, under strict hygienic requirements only amplify it. The Temperature transmitter specification must therefore cover choosing integral or remote versions by ambient, Ex zone and mounting.

Delivery Approach

Delivery was handled as the temperature range — temperature solution matched to measuring point and response needs. Execution centred on choosing integral or remote versions by ambient, Ex zone and mounting, together with food-safety and hygienic design per 3-A / EHEDG.

Field Results

Operation shows the benefit clearly — better noise immunity and much smaller transmission error, with confidence in this measuring point improving markedly.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Temperature transmitter — Application Case

Customer Profile

The typical setting in Chemical & Pharmaceutical is reactors, metering vessels and finished-product tanks. The measuring point is Temperature transmitter; the focus is converting RTD or thermocouple signals into a standard current output.

Key Difficulties

Conditions are highly corrosive media with solvents and crystallisation, partly in explosive atmospheres and, on top of that, corrosion plus Ex protection shortens instrument life and makes downtime costly, which a standard configuration cannot handle for long. The design therefore starts with choosing integral or remote versions by ambient, Ex zone and mounting.

Implementation

The scope ran through the temperature range: temperature solution matched to measuring point and response needs. Technically it hinges on choosing integral or remote versions by ambient, Ex zone and mounting, and on these requirements: Ex certification and GMP traceability of records.

Customer Benefit

In practice this means better noise immunity and much smaller transmission error, which cut the workload on the site maintenance team.

Power & Energy

Power & Energy · Temperature transmitter — Application Case

Project Background

The project covers boiler feedwater, turbine condensate and FGD/DeNOx systems. The work centres on Temperature transmitter and the core task is converting RTD or thermocouple signals into a standard current output.

Operating Challenges

The medium and duty are characterised by high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. So Temperature transmitter cannot be specified generically — it calls for choosing integral or remote versions by ambient, Ex zone and mounting.

Solution

The Ainstru engineering team worked through the temperature range: temperature solution matched to measuring point and response needs. The configuration involves choosing integral or remote versions by ambient, Ex zone and mounting, with these requirements in view: compliance with power-industry codes and unit availability targets.

Results

Since start-up the system has run steadily; the practical result is better noise immunity and much smaller transmission error.