Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

TMT162 on-site temperature transmitter

TMT162 on-site temperature transmitter
iTEMP TMT162, Field Transmitter
Configurable Models 1 models
Electronic monitoring, conversion, and display of input signals using HART, foundation fieldbus ™ H1 or PROFIBUS ® PAHART ® Communication for all industries
Compare

Temperature transmitters

Measuring Principle Field transmitter
Input 2 x RTD, TC, Ohm, mV
Output 1 x analog 4...20 mA / HART
FOUNDATION Fieldbus H1
PROFIBUS PA
Auxiliary power supply 11,5...42 V DC (HART)
11,5...30 V DC (Ex ia)
9...32 V DC (FF, PA)
10,5...24 V DC (Ex ia, FF, PA)
Communication HART
FOUNDATION Fieldbus
PROFIBUS PA
Installation in field
Accuracy (Pt100) <= 0,1 K (HART, FF, PA)
(Pt100) <= 0,18 °F (HART, FF, PA)
Galvanic isolation yes
Certification UL rec. Comp (HART)
marine approval only for HART-protocol
SIL2/3 only for HART-protocol
ATEX Ex ia, Ex d, Ex tb, Ex ic, Ex nA
ATEX IECEx Ex tb
IECEx Ex ia, Ex d, Ex tb
CSA IS, NI, XP, DIP
CSA General Purpose
FM IS, NI, XP, DIP
FM+CSA XP,DIP, IS, NI
INMETRO Ex ia, Ex db, Ex tb
NEPSI Ex ia, Ex nA, Ex d
EAC Ex ia, Ex d
UKCA Ex db, Ex ia, Ex nA
PESO Ex ia
IND Ex ia
KC

Outstanding reliability, accuracy and long-term stability in critical process applications in all industries. Connected to a remote temperature transmitter, it transmits converted signals from RTD sensors and thermocouples, while also transmitting resistance and voltage signals using HART, FF Fieldbus™ H1 or PROFIBUS® PA HART® communication. Signals can be shown on a backlit display. The robust housing is suitable for field installation and can be used directly in demanding process areas, and is also available as an option for hygienic applications.

 

Advantages

Dual-compartment housing and one-piece fully sealed electronics for high reliability under harsh operating conditions

Backlit display with large measured value, bar graph and status indication

Diagnostic information complies with NAMUR NE107

International approvals such as FM, CSA (IS, NI, XP and DIP) and ATEX (Ex ia, Ex nA nL, Ex d and dust explosion protection); marine approval

SIL approval in accordance with IEC 61508:2010

2 kV isolation voltage (sensor input/output)

Spare Parts & Accessories 26

26 spare parts · click to collapse
Order codeDescription
TMT162X-Spare part TMT162XEnquire
TMT162X-Spare part TMT162XEnquire
TMT162G-Housing TMT162GEnquire
TMT162X-Spare part TMT162XEnquire
51004948front cover latch pinScrew, washer, spring washerDetails
71502617O-ring 88x3 HNBR 70° Shore PTFE_5pcsPacking unit: 5 piecesDetails
71158816O-ringDetails
TMT162X-Spare part TMT162XEnquire
TMT162E-Electronic module TMT162EAttention: Only 1 piece per position orderable in offer/order because of item category group ZTA1.Enquire
TMT162G-Housing TMT162GEnquire
TMT162X-Spare part TMT162XEnquire
FXA195-Communication interface FXA195Modem to connect HART field devices to a computer via USB. Commissioning of field devices with software tool. :: To connect to a intrinsically safe signal circuit. :: SIL2, IEC61508.Enquire
XPT0002-plug connectorEnquire
51006845cable glandCable gland NPT 1/2, D4-8.5, IP68Details
71638066Cable gland M20x1.5 ATEX/IECExDetails
51004915M24x1.5 to M20x1.5 adapterAdapter M20x1.5 exter./M24x1.5 intern.VADetails
71502941O-Ring 18.77x1.78 HNBR 70° Shore PTFEPacking unit: 10 piecesDetails
51006888blind coverDetails
51004490blind coverDetails
71525620Blind plug M20x1.5 Ex-d + O-ring, aluminiumDetails

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

Accessories / Spare parts

 

Measuring principle video

Click to play
1 models · click to collapse
Diagnostic codes(34 条)→
All documents for this model
12 documents · click to expand
BA

BA iTEMP TMT162 Chinese

Rev. 0424 114 pages
Preview
BA

BA iTEMP TMT162 English

Rev. 1623 88 pages
Preview
BA

Temperature field transmitter iTEMP TMT162, HART 5 specification English

HART Rev. 1419 160 pages
Preview
BA

iTEMP® TMT162 FOUNDATION Fieldbus™ Operating Instructions English

FOUNDATION-Fieldbus Rev. 1310 80 pages
Preview
BA

Operating instruction iTEMP TMT162 PROFIBUS® PA Temperature field transmitter English

Rev. 1209 94 pages
Preview
BA

BA iTEMP TMT162 English

Rev. 0424 122 pages
Preview
BA

Operating instructions iTEMP HART TMT162 Temperature field transmitter English

HART Rev. 0410 156 pages
Preview
BA

BA iTEMP TMT162 English

Rev. 0323 96 pages
Preview
BA

Operating instruction iTEMP TMT162 PROFIBUS® PA Temperature field transmitter English

Rev. 0111 94 pages
Preview
BA

Operating Manuals ReadWin 2000 (GB) English

Rev. 0110 124 pages
Preview
BA

ReadWin® Quick Setup English

15 pages
Preview
BA

Operating Manuals ReadWin 2000 (GB) English

64 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Temperature transmitter — Application Case

Site Conditions

This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was converting RTD or thermocouple signals into a standard current output.

The Problem

The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means choosing integral or remote versions by ambient, Ex zone and mounting.

What We Did

We took a temperature range approach — temperature solution matched to measuring point and response needs. Delivery was built around choosing integral or remote versions by ambient, Ex zone and mounting, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.

Operating Outcome

In service the system performs as intended — better noise immunity and much smaller transmission error, with routine maintenance falling noticeably.

Food & Beverage

Food & Beverage · Temperature transmitter — Application Case

Application Context

dosing, pasteurising, filling and CIP stages is a typical Food & Beverage duty. The project started from Temperature transmitter, focusing on converting RTD or thermocouple signals into a standard current output.

Process Constraints

frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, and syrups, dairy and beverages that scale easily, under strict hygienic requirements only amplify it. The Temperature transmitter specification must therefore cover choosing integral or remote versions by ambient, Ex zone and mounting.

Delivery Approach

Delivery was handled as the temperature range — temperature solution matched to measuring point and response needs. Execution centred on choosing integral or remote versions by ambient, Ex zone and mounting, together with food-safety and hygienic design per 3-A / EHEDG.

Field Results

Operation shows the benefit clearly — better noise immunity and much smaller transmission error, with confidence in this measuring point improving markedly.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Temperature transmitter — Application Case

Customer Profile

The typical setting in Chemical & Pharmaceutical is reactors, metering vessels and finished-product tanks. The measuring point is Temperature transmitter; the focus is converting RTD or thermocouple signals into a standard current output.

Key Difficulties

Conditions are highly corrosive media with solvents and crystallisation, partly in explosive atmospheres and, on top of that, corrosion plus Ex protection shortens instrument life and makes downtime costly, which a standard configuration cannot handle for long. The design therefore starts with choosing integral or remote versions by ambient, Ex zone and mounting.

Implementation

The scope ran through the temperature range: temperature solution matched to measuring point and response needs. Technically it hinges on choosing integral or remote versions by ambient, Ex zone and mounting, and on these requirements: Ex certification and GMP traceability of records.

Customer Benefit

In practice this means better noise immunity and much smaller transmission error, which cut the workload on the site maintenance team.

Power & Energy

Power & Energy · Temperature transmitter — Application Case

Project Background

The project covers boiler feedwater, turbine condensate and FGD/DeNOx systems. The work centres on Temperature transmitter and the core task is converting RTD or thermocouple signals into a standard current output.

Operating Challenges

The medium and duty are characterised by high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. So Temperature transmitter cannot be specified generically — it calls for choosing integral or remote versions by ambient, Ex zone and mounting.

Solution

The Ainstru engineering team worked through the temperature range: temperature solution matched to measuring point and response needs. The configuration involves choosing integral or remote versions by ambient, Ex zone and mounting, with these requirements in view: compliance with power-industry codes and unit availability targets.

Results

Since start-up the system has run steadily; the practical result is better noise immunity and much smaller transmission error.