Technical Data
CompareTemperature transmitters
| Measuring Principle | Head transmitter |
| Input | 1 x RTD, TC, Ohm, mV |
| Output | 1 x analog 4...20 mA |
| Auxiliary power supply | 10...36 V DC (standard-version) 10...30 V DC (Ex-version) |
| Communication | HART-protocol |
| Installation | Terminal head form B |
| Accuracy | (Pt100, 0…200°C) <= 0,10 K (Pt100, 32…392°F) <= 0,18 °F |
| Galvanic isolation | yes |
| Certification | ATEX Ex ia, Ex ec ATEX IECEx Ex ia NEPSI Ex ia |
Advantages
-
Multiple international certifications allow safe use in hazardous areas
-
Equipped with sensor and device monitoring functions for reliable measurement
-
Diagnostic information complies with NAMUR NE107
-
Always ready for use: can be pre-programmed at the factory if required
-
Free software, simple configuration
Application
-
Universal temperature transmitter with HART® communication that converts different types of input signals into a scalable 4...20 mA analog output signal
-
The iTEMP TMT182B offers high reliability, high long-term stability and high measurement accuracy, and is equipped with advanced diagnostic functions, particularly meeting the measurement requirements of critical process stages
-
Highest safety and reliability, reducing the risk of use
-
Allows connection of universal input signals: resistance thermometers (RTD), thermocouples (TC), resistance (Ω) and voltage (mV)
-
For installation in Type B (flat-face) connection heads
Spare Parts & Accessories 4
4 spare parts · click to collapse
| Order code | Description | |
|---|---|---|
| 71044061 | equipment package2x screws, 2x springs, 2x spring rings, 1x sealing CDI-connector | Details |
| 71044062 | equipment package2x screws, 1x sealing CDI-connector | Details |
| FXA195- | Communication interface FXA195Modem to connect HART field devices to a computer via USB. Commissioning of field devices with software tool. :: To connect to a intrinsically safe signal circuit. :: SIL2, IEC61508. | Enquire |
| 71528231 | DIN rail mounting accessoryClip according to IEC 60715 for temperature head transmitters. Packing unit: 2 pieces | Details |
Configurator / Comparison
Source:Endress+Hauserpublic information from the website
Manuals & Documents 4
All documents for this modelCase Studies
Municipal Wastewater Treatment · Temperature transmitter — Application Case
Site Conditions
This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was converting RTD or thermocouple signals into a standard current output.
The Problem
The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means choosing integral or remote versions by ambient, Ex zone and mounting.
What We Did
We took a temperature range approach — temperature solution matched to measuring point and response needs. Delivery was built around choosing integral or remote versions by ambient, Ex zone and mounting, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.
Operating Outcome
In service the system performs as intended — better noise immunity and much smaller transmission error, with routine maintenance falling noticeably.
Food & Beverage · Temperature transmitter — Application Case
Application Context
dosing, pasteurising, filling and CIP stages is a typical Food & Beverage duty. The project started from Temperature transmitter, focusing on converting RTD or thermocouple signals into a standard current output.
Process Constraints
frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, and syrups, dairy and beverages that scale easily, under strict hygienic requirements only amplify it. The Temperature transmitter specification must therefore cover choosing integral or remote versions by ambient, Ex zone and mounting.
Delivery Approach
Delivery was handled as the temperature range — temperature solution matched to measuring point and response needs. Execution centred on choosing integral or remote versions by ambient, Ex zone and mounting, together with food-safety and hygienic design per 3-A / EHEDG.
Field Results
Operation shows the benefit clearly — better noise immunity and much smaller transmission error, with confidence in this measuring point improving markedly.
Chemical & Pharmaceutical · Temperature transmitter — Application Case
Customer Profile
The typical setting in Chemical & Pharmaceutical is reactors, metering vessels and finished-product tanks. The measuring point is Temperature transmitter; the focus is converting RTD or thermocouple signals into a standard current output.
Key Difficulties
Conditions are highly corrosive media with solvents and crystallisation, partly in explosive atmospheres and, on top of that, corrosion plus Ex protection shortens instrument life and makes downtime costly, which a standard configuration cannot handle for long. The design therefore starts with choosing integral or remote versions by ambient, Ex zone and mounting.
Implementation
The scope ran through the temperature range: temperature solution matched to measuring point and response needs. Technically it hinges on choosing integral or remote versions by ambient, Ex zone and mounting, and on these requirements: Ex certification and GMP traceability of records.
Customer Benefit
In practice this means better noise immunity and much smaller transmission error, which cut the workload on the site maintenance team.
Power & Energy · Temperature transmitter — Application Case
Project Background
The project covers boiler feedwater, turbine condensate and FGD/DeNOx systems. The work centres on Temperature transmitter and the core task is converting RTD or thermocouple signals into a standard current output.
Operating Challenges
The medium and duty are characterised by high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. So Temperature transmitter cannot be specified generically — it calls for choosing integral or remote versions by ambient, Ex zone and mounting.
Solution
The Ainstru engineering team worked through the temperature range: temperature solution matched to measuring point and response needs. The configuration involves choosing integral or remote versions by ambient, Ex zone and mounting, with these requirements in view: compliance with power-industry codes and unit availability targets.
Results
Since start-up the system has run steadily; the practical result is better noise immunity and much smaller transmission error.
Related Products
Endress+HauseriTEMP TMT72, Transmitter HART
Endress+HauseriTEMP TMT182, Head Transmitter HART
Endress+HauseriTEMP TMT82, Transmitter HART
Endress+HauseriTEMP TMT71, Transmitter 4-20mA
Endress+HauseriTEMP TMT80, Head Transmitter
Endress+HauseriTEMP TMT31, Transmitter 4-20mA
Endress+HauseriTEMP TMT142, Field Transmitter HART
Endress+Hauser