Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

PS68.XXE1E2HKMXV

PS68.XXE1E2HKMXV
Product family: Antenna cover for VEGAPULS 68
Antenna cover for VEGAPULS 68
VEGA PS68.XXE1E2HKMXV
PS68.XXE1E2HKMXV;Approval without;Version / Material with horn antenna (ø95mm) / 316L;Process fitting / Material Swivelling holder with flange DN200 PN16 / 316/316L;Seal / Process temperature FKM (SHS

Order Code:PS68.XXE1E2HKMXV

Name:PS68.XXE1E2HKMXV

Configuration

CodeNameOrderSpecification
030ApprovalXXwithout
050Version / MaterialEwith horn antenna (ø95mm) / 316L
060Process fitting / Material1ESwivelling holder with flange DN200 PN16 / 316/316L
080Seal / Process temperature2FKM (SHS FPM 70C3 GLT) and PTFE / -40...+130°C
090ElectronicsHTwo-wire 4 ... 20 mA/HART
120Housing / ProtectionKPlastic single chamber / IP66/IP67
140Cable entry / Cable gland / Plug connectionMM20x1.5 / with / without
150Display/Adjustment module PLICSCOMXwithout
160Additional equipmentVRinsing connection with reflux valve

Configuration Explained

This is a VEGAPULS 68 radar level transmitter, 95 mm horn antenna, 316L, process connection swivel mounting bracket with DN200 PN16 flange, FKM plus PTFE seal, process temperature -40 to 130°C, two-wire 4-20mA HART, plastic single chamber housing IP66/67, without display, the flushing connection has a return valve and resets automatically after flushing, suitable for automatic purging of large tanks.