Product family:
Antenna cover for VEGAPULS 68
Antenna cover for VEGAPULS 68
PS68.XXXFKHIWMKX;Approval without;Version / Material for separate horn antenna;Process fitting / Material Flange DN150 PN16 Form C, DIN2501 / 316/316L;Seal / Process temperature Ceramic graphite / -19
Order Code:PS68.XXXFKHIWMKX
Name:PS68.XXXFKHIWMKX
Configuration
| Code | Name | Order | Specification |
|---|---|---|---|
| 030 | Approval | XX | without |
| 050 | Version / Material | X | for separate horn antenna |
| 060 | Process fitting / Material | FK | Flange DN150 PN16 Form C, DIN2501 / 316/316L |
| 080 | Seal / Process temperature | H | Ceramic graphite / -196...+450°C |
| 090 | Electronics | I | Four-wire 4 ... 20 mA/HART; 9.6 ... 48 V DC; 20 ... 42 V AC |
| 120 | Housing / Protection | W | Stainless steel double chamber / IP66/IP68 (0.2 bar) |
| 140 | Cable entry / Cable gland / Plug connection | M | M20x1.5 / with / without |
| 150 | Display/Adjustment module PLICSCOM | K | mounted; with Bluetooth, magnetic pen operation |
| 160 | Additional equipment | X | without |
Configuration Explained
This is a VEGAPULS 68 radar level transmitter for a detached horn antenna, process connection DN150 PN16 Form C flange, 316/316L, ceramic graphite seal, process temperature -196 to 450°C, four-wire 4-20mA HART, power supply 9.6 to 48V DC or 20 to 42V AC, stainless steel dual chamber housing IP66/68, Bluetooth display operable with a magnetic pen, suitable for cryogenic and high temperature tanks.
Related Products
Endress+HauserFlowfit W CPA250 flow-through holder
View →
Endress+HauserEcofit CPA640 pH holder with adapter set
View →
Endress+HauserFlowfit P CPA240
View →
Endress+HauserCleanfit W CPA450
View →
Endress+HauserCleanfit CPA871
View →
Endress+HauserDipfit P CPA140
View →
Endress+HauserFLEXDIP CYA112
View →
Endress+HauserDipfit W CPA111
View →