Technical Data
CompareLiquids
| Measuring Principle | Coriolis |
| Product headline | The compact sensor with an ultra-compact transmitter. Measurement of liquids with the most diverse properties in continuous process control & batching applications. |
| Sensor features | High process safety – high measuring accuracy for different media in shortest filling time. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Nominal diameter: DN 8 to 25 (³⁄₈ to 1"). Various hygienic process connections, 3-A conform. CIP, SIP cleanable sensor. |
| Transmitter features | Versatile and time-saving wiring – plug connector. Fast commissioning – pre-configured devices. Automatic recovery of data for servicing. Robust, ultra‐compact transmitter housing. Pulse/frequency/switch output, Modbus RS485. Excellent and easily cleanable transmitter. |
| Nominal diameter range | DN 8 to 25 (³⁄₈ to 1") |
| Wetted materials | Measuring tube: 1.4539 (904L) Connection: 1.4404 (316/316L) |
| Measured variables | Mass flow, density, temperature, volume flow |
| Max. measurement error | Mass flow (liquid): ±0.15 % Density (liquid): ±0.0005 g/cm³ |
| Measuring range | 0 to 18 000 kg/h (0 to 660 lb/min) |
| Max. process pressure | PN 40 |
| Medium temperature range | –40 to +125 °C (–40 to +257 °F) 150 °C allowed for 1 h |
| Ambient temperature range | –20 to +60 °C (–4 to +140 °F) |
| Sensor housing material | 1.4301 (304), corrosion resistant |
| Transmitter housing material | 1.4308 (304) |
| Degree of protection | IP67, type 4X enclosure |
| Display/Operation | No local operation Configuration via operating tools possible |
| Outputs | Pulse/frequency/switch output (passive) |
| Inputs | None |
| Digital communication | Modbus RS485 |
| Power supply | DC 20 to 30 V |
| Hazardous area approvals | ATEX, IECEx, cCSAus |
| Other approvals and certificates | 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR 3-A |
| Product safety | CE |
The Dosimass is used for flow measurement in filling and bottling processes. It directly measures volume flow and mass flow with temperature and density compensation, ensuring maximum repeatability. The Dosimass is suitable for use in confined spaces and is the preferred choice of system integrators, brake system manufacturers and equipment manufacturers.
Advantages
Small housing meets the installation requirements of rotary linear filling machines.
High measuring accuracy
Via Endress+Hauser’s FieldCare operating software:
1. Graphical display enables accurate analysis and optimization of batching processes
2. Complete system documentation can be compiled on the basis of device configuration and batch diagrams
3A approval
CIP and SIP cleaning, as well as external cleaning with corrosive media
No moving parts
Application areas
Suitable as a mass or volume flowmeter in filling process applications.
Measures the widest range of liquid properties in the following fields
Food industry
Beverage industry
Cosmetics industry
Chemical industry
Petrochemical industry
Spare Parts & Accessories 12
12 spare parts · click to collapse
| Order code | Description | |
|---|---|---|
| 50106416 | *** Power Module | Details |
| 50106219 | fuse | Details |
| 50104802 | cover seal ring | Details |
| 50106443 | FXA commissioning toolFXA service adapter Batchline packed | Details |
| 71035809 | 5BH Commissioning Cable, Y-Type Cable | Details |
| 50107167 | Adapter RSE4 8-pole -> 4-pole, 4-wire | Details |
| 50107168 | adapter | Details |
| 50107169 | Adapter RSE8 8-pin -> 8-pin, 5-wire | Details |
| 50107895 | Connecting cable RKWTN8-56/5 P92, 5 mCaution: Please note that this cable is not approved for use in ATEX Zone 2 or UL Class 1 Division 2 areas. This cable is not shielded. Use a shielded twisted pair cable for Modbus RS485 applications. | Details |
| 51516983 | Communication interface FXA291Serial USB Computer Interface Technical Data: - USB Version1.1 or higher - Power supply via USB - IP51; NEMA/Typ 3 - Ambient temperature: -20....+60oC - Ex: II(2) G (EEx ia) II C - ATEX: BVS 05 ATEX E 095 Scope of deliovery: Commubox FXA 291 MS Windows USB driver Device is submitted for CSA/FM application. The device may not be modified and may be used with intrinsically safe circuits with corresponding characteristics only (see safety certificate). | Details |
| 8BE- | Dosimass, 8BECoriolis mass flowmeter for filling applications (compact version) Housing in stainless steel | Enquire |
| FXA193- | *** Communication Interface FXA193The service interface connects the service port of Proline and ToF devices with the serial interface RS 232C (9 pin.) of a personal computer. Contents of delivery: - Serviceinterface with RS 232C connection cable (9 pin.) - FXA "USB" cable, the additional power supply for FXA193 from USB-port of the PC. - Service Softw.ToF Tool-Fieldtool Package | Enquire |
Configurator / Comparison
Accessories / Spare parts
Measuring principle video
Click to playCase Studies
Municipal Wastewater Treatment · Mass Flow Meter — Application Case
Application Context
the inlet, biological and outlet stages of a municipal plant is a typical Municipal Wastewater Treatment duty. The project started from Mass Flow Meter, focusing on direct mass flow and density measurement.
Process Constraints
effluent parameters drift and probes foul with sludge and biofilm, and high solids and corrosive fractions, with large diurnal flow swings only amplify it. The Mass Flow Meter specification must therefore cover choosing tube geometry by flow range, entrained gas and hygienic needs.
Delivery Approach
Delivery was handled as the flow range — flow solution matched to line size, medium and range. Execution centred on choosing tube geometry by flow range, entrained gas and hygienic needs, together with stable compliance with Grade 1A discharge limits and online data reporting.
Field Results
Operation shows the benefit clearly — no temperature or pressure compensation needed, making custody transfer more credible, with confidence in this measuring point improving markedly.
Food & Beverage · Mass Flow Meter — Application Case
Customer Profile
The typical setting in Food & Beverage is dosing, pasteurising, filling and CIP stages. The measuring point is Mass Flow Meter; the focus is direct mass flow and density measurement.
Key Difficulties
Conditions are syrups, dairy and beverages that scale easily, under strict hygienic requirements and, on top of that, frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, which a standard configuration cannot handle for long. The design therefore starts with choosing tube geometry by flow range, entrained gas and hygienic needs.
Implementation
The scope ran through the flow range: flow solution matched to line size, medium and range. Technically it hinges on choosing tube geometry by flow range, entrained gas and hygienic needs, and on these requirements: food-safety and hygienic design per 3-A / EHEDG.
Customer Benefit
In practice this means no temperature or pressure compensation needed, making custody transfer more credible, which cut the workload on the site maintenance team.
Chemical & Pharmaceutical · Mass Flow Meter — Application Case
Project Background
The project covers reactors, metering vessels and finished-product tanks. The work centres on Mass Flow Meter and the core task is direct mass flow and density measurement.
Operating Challenges
The medium and duty are characterised by highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. So Mass Flow Meter cannot be specified generically — it calls for choosing tube geometry by flow range, entrained gas and hygienic needs.
Solution
The Ainstru engineering team worked through the flow range: flow solution matched to line size, medium and range. The configuration involves choosing tube geometry by flow range, entrained gas and hygienic needs, with these requirements in view: Ex certification and GMP traceability of records.
Results
Since start-up the system has run steadily; the practical result is no temperature or pressure compensation needed, making custody transfer more credible.
Power & Energy · Mass Flow Meter — Application Case
Project Overview
The site is boiler feedwater, turbine condensate and FGD/DeNOx systems. The customer wanted Mass Flow Meter properly configured on the existing plant, with the aim of direct mass flow and density measurement.
Technical Challenges
What actually causes trouble is high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. All of this means the Mass Flow Meter configuration has to involve choosing tube geometry by flow range, entrained gas and hygienic needs.
Configuration
Supply and installation were organised through the flow range: flow solution matched to line size, medium and range. On site this meant choosing tube geometry by flow range, entrained gas and hygienic needs, checked line by line against: compliance with power-industry codes and unit availability targets.
Performance
After commissioning the outcome is no temperature or pressure compensation needed, making custody transfer more credible, and the readings are now used for process tuning.
Related Products
Endress+HauserMass flowmeter 8E3B
Endress+HauserCompact mass flowmeter
Endress+HauserMass flowmeter Promass K 10
Endress+HauserMass flowmeter
Endress+HauserMass flowmeter
Endress+HauserCNG dispenser mass flowmeter 8FF
Endress+HauserMass flowmeter 8F5B
Endress+Hauser