When it comes to billing and paying for the amount of CNG actually pumped, the measuring accuracy at the dispenser is just as important as with any other fuel. Therefore, the “brain” in every CNG dispenser is a flowmeter that measures the quantity of fuel transferred from dispenser to vehicle with the absolute highest accuracy – reliability day in, day out, round the clock. These are some of the benefits of CNGmass, which has been specifically designed for such applications.
Compare

Gas

Measuring Principle Coriolis
Product headline The refueling application flowmeter with easy system integration. Accurate measurement of compressed natural gas (CNG) in high pressure refueling applications.
Sensor features Excellent operational safety – reliable under extreme process conditions. Fewer process measuring points – multivariable measurement (flow, density, temp). Spacesaving installation – no in/outlet run needs. Flow rates up to 150 kg/min (330 lb/min). Process pressure up to 350 bar (5080 psi).
Transmitter features Easy operation – reduced to application needs. Fast commissioning – pre‐configured devices. Automatic recovery of data for servicing. Robust, ultra‐compact transmitter housing. Pulse output and Modbus RS485.
Nominal diameter range DN 8 to 25 (⅜ to 1")
Wetted materials Measuring tube: 1.4435 (316L)
Connection: 1.4404 (316)
Measured variables Mass flow, density, temperature, volume flow
Max. measurement error Mass flow: ±0.5 % of batch
Measuring range 0 to 150 kg/min (0 to 330 lb/min)
Max. process pressure 350 bar (5080 psi)
Medium temperature range –50 to +125 °C (–58 to +257 °F)
Ambient temperature range –40 to +60 °C (–40 to +140 °F)
Sensor housing material 1.4301 (304), corrosion resistant
Transmitter housing material Powder‐coated die‐cast aluminium
Degree of protection IP67, type 4X enclosure
Display/Operation No local operation
Configuration via operating tools possible
Outputs Pulse/frequency/switch output (passive), phase‐shifted pulse
Inputs None
Digital communication Modbus RS485
Power supply DC 10 to 30 V AC 20 to 28 V
Hazardous area approvals ATEX, IECEx, NEC/CEC, FM, CSA, NEPSI, UL
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), custody transfer
PTB, BEW, LNE, Rosstandart, NTEP approvals
Pressure approvals and certificates CRN
Material certificates 3.1 material

Liquids

Measuring Principle Coriolis
Product headline The refueling application flowmeter with easy system integration. Accurate measurement of compressed natural gas (CNG) in high pressure refueling applications.
Sensor features Excellent operational safety – reliable under extreme process conditions. Fewer process measuring points – multivariable measurement (flow, density, temp). Spacesaving installation – no in/outlet run needs. Flow rates up to 150 kg/min (330 lb/min). Process pressure up to 350 bar (5080 psi).
Transmitter features Easy operation – reduced to application needs. Fast commissioning – pre‐configured devices. Automatic recovery of data for servicing. Robust, ultra‐compact transmitter housing. Pulse output and Modbus RS485.
Nominal diameter range DN 8 to 25 (⅜ to 1")
Wetted materials Measuring tube: 1.4435 (316L)
Connection: 1.4404 (316)
Measured variables Mass flow, density, temperature, volume flow
Max. measurement error Mass flow: ±0.5 % of batch
Measuring range 0 to 150 kg/min (0 to 330 lb/min)
Max. process pressure 350 bar (5080 psi)
Medium temperature range –50 to +125 °C (–58 to +257 °F)
Ambient temperature range –40 to +60 °C (–40 to +140 °F)
Sensor housing material 1.4301 (304), corrosion resistant
Transmitter housing material Powder‐coated die‐cast aluminium
Degree of protection IP67, type 4X enclosure
Display/Operation No local operation
Configuration via operating tools possible
Outputs Pulse/frequency/switch output (passive), phase‐shifted pulse
Inputs None
Digital communication Modbus RS485
Power supply DC 10 to 30 V AC 20 to 28 V
Hazardous area approvals ATEX, IECEx, NEC/CEC, FM, CSA, NEPSI, UL
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
PTB, BEW, LNE, Rosstandart, NTEP approvals
Pressure approvals and certificates CRN
Material certificates 3.1 material

Advantages
FieldCare for on-site operation and diagnostics
Extremely low energy consumption
Space-saving one-piece design
Balanced twin-tube measuring system design with good vibration resistance
No inlet/outlet straight runs required, simple installation

Application areas
Coriolis measuring principle is unaffected by the physical properties of the fluid itself, such as viscosity and density.
Designed specifically for vehicles running on natural gas (CNG).
Fluid temperature can reach +125 °C (+257 °F)
Process pressure up to 350 bar (5080 psi)
Mass flow measurement up to 150 kg/min (330 lb/min)
Hazardous area approvals
ATEX, FM, CSA, NEPSI
Universal control connection
Modbus RS485

 

Spare Parts & Accessories 8

8 spare parts · click to collapse
Order codeDescription
71034464Electronic ModuleDetails
71034612blind cover8FF/8FE/8CMDetails
50106386Terminal compartment cover72/73/92F/8FF/8FEDetails
50097147Grounding terminal / Cover locking clamp10/1YH/23/65/72/73/91W/92F/8FF/8FE/8CMDetails
50098036Explosion-proof cable glandKit 10 cable glands M20x1.5 ExDetails
50098042adapterKit 10 extension M20x1.5/NPT 1/2"Details
50098041adapterKit 10 extension M20x1.5/G 1/2"Details
5010869184 Lead SealKit Screw sealing Pmass 84Details

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

Accessories / Spare parts

 

Measuring principle video

Click to play
All documents for this model
5 documents · click to expand
BA

CNGmass MODBUS RS485 Operating Instructions and Description of Device Functions English

Rev. 1622 104 pages
Preview
BA

CNGmass MODBUS RS485 Operating Instructions and Description of Device Functions English

Rev. 0410 104 pages
Preview
TI

CNGmass Technical Information Chinese

Rev. 1623 16 pages
Preview
TI

CNGmass Technical Information English

Rev. 1623 16 pages
Preview
TI

CNGmass Technical Information English

Rev. 0410 20 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Mass Flow Meter — Application Case

Application Context

the inlet, biological and outlet stages of a municipal plant is a typical Municipal Wastewater Treatment duty. The project started from Mass Flow Meter, focusing on direct mass flow and density measurement.

Process Constraints

effluent parameters drift and probes foul with sludge and biofilm, and high solids and corrosive fractions, with large diurnal flow swings only amplify it. The Mass Flow Meter specification must therefore cover choosing tube geometry by flow range, entrained gas and hygienic needs.

Delivery Approach

Delivery was handled as the flow range — flow solution matched to line size, medium and range. Execution centred on choosing tube geometry by flow range, entrained gas and hygienic needs, together with stable compliance with Grade 1A discharge limits and online data reporting.

Field Results

Operation shows the benefit clearly — no temperature or pressure compensation needed, making custody transfer more credible, with confidence in this measuring point improving markedly.

Food & Beverage

Food & Beverage · Mass Flow Meter — Application Case

Customer Profile

The typical setting in Food & Beverage is dosing, pasteurising, filling and CIP stages. The measuring point is Mass Flow Meter; the focus is direct mass flow and density measurement.

Key Difficulties

Conditions are syrups, dairy and beverages that scale easily, under strict hygienic requirements and, on top of that, frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, which a standard configuration cannot handle for long. The design therefore starts with choosing tube geometry by flow range, entrained gas and hygienic needs.

Implementation

The scope ran through the flow range: flow solution matched to line size, medium and range. Technically it hinges on choosing tube geometry by flow range, entrained gas and hygienic needs, and on these requirements: food-safety and hygienic design per 3-A / EHEDG.

Customer Benefit

In practice this means no temperature or pressure compensation needed, making custody transfer more credible, which cut the workload on the site maintenance team.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Mass Flow Meter — Application Case

Project Background

The project covers reactors, metering vessels and finished-product tanks. The work centres on Mass Flow Meter and the core task is direct mass flow and density measurement.

Operating Challenges

The medium and duty are characterised by highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. So Mass Flow Meter cannot be specified generically — it calls for choosing tube geometry by flow range, entrained gas and hygienic needs.

Solution

The Ainstru engineering team worked through the flow range: flow solution matched to line size, medium and range. The configuration involves choosing tube geometry by flow range, entrained gas and hygienic needs, with these requirements in view: Ex certification and GMP traceability of records.

Results

Since start-up the system has run steadily; the practical result is no temperature or pressure compensation needed, making custody transfer more credible.

Power & Energy

Power & Energy · Mass Flow Meter — Application Case

Project Overview

The site is boiler feedwater, turbine condensate and FGD/DeNOx systems. The customer wanted Mass Flow Meter properly configured on the existing plant, with the aim of direct mass flow and density measurement.

Technical Challenges

What actually causes trouble is high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. All of this means the Mass Flow Meter configuration has to involve choosing tube geometry by flow range, entrained gas and hygienic needs.

Configuration

Supply and installation were organised through the flow range: flow solution matched to line size, medium and range. On site this meant choosing tube geometry by flow range, entrained gas and hygienic needs, checked line by line against: compliance with power-industry codes and unit availability targets.

Performance

After commissioning the outcome is no temperature or pressure compensation needed, making custody transfer more credible, and the readings are now used for process tuning.