Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

8F3B Compact mass flowmeter

8F3B Compact mass flowmeter
Compact mass flowmeter
Configurable Models 20 models
Premium high-precision flowmeter, rugged and durable, with an easy-to-operate compact transmitter. 8F3B, also known as F 300, is the upgraded version of E+H's best-regarded mass flowmeter series, the 80F, and holds the largest market share within E+H's 8-series mass flowmeters, widely favored for its high accuracy and stability.

The 8F series is a high-precision (0.1 % to 0.05 %) mass flowmeter; the 8F3B is the four-wire version. If a two-wire version is required, please use the 8F2B.

The Promass F is a proven high-precision sensor. Unaffected by fluctuations and harsh environments, it is used in a wide range of applications. Used with a compact transmitter, the Promass F 300 offers flexible operation and convenient system integration: wiring on the same side of the instrument, remote display and improved connection options. Heartbeat Technology ensures compliance at all times and guarantees process safety.

 

Benefits

Highest process safety: unaffected by fluctuations and harsh conditions

Fewer process measuring points: multi-parameter measurement (flow, density, temperature)

Space-saving installation: no upstream/downstream straight pipe run requirements

Complete view of process and diagnostic information: various user-defined input/output combinations and fieldbuses available

Reduced complexity and variety: user-defined input/output functions

Built-in verification: integrated Heartbeat Technology

 

Application areas

Measuring principle unaffected by the physical properties of the fluid (e.g. viscosity and density).

Liquid and gas measurement under changing, demanding process conditions with the highest measuring performance.

Instrument features

Mass flow measuring accuracy: ±0.05 % (PremiumCal)

Medium temperature: -196...350 °C (-320...662 °F)

Nominal diameter: DN 8...250 (3/8...10")

Compact dual-compartment housing with up to 3 inputs/outputs

Backlit display, touch key control and WLAN access

Separate display unit available

Spare Parts & Accessories 69

69 spare parts · click to collapse
Order codeDescription
XPD0028-300/500 ISEM electronic plug-in moduleUsage: Promass, Cubemass 300/500, HPFmass 500Enquire
XPD0037-I/O moduleUsage: Proline 300/500Enquire
XPD0038-I/O moduleUsage: Proline 300/500Enquire
XPD0031-Display moduleUsage: Proline 300/500, DKX001.Enquire
71323007Power supply assemblyUsage: Promag/Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing, electronic compartment.Details
71323008Power supply assemblyUsage: Promag/Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing, electronic compartment.Details
71323009Power supply assemblyUsage: Promag/Promass/Prosonic Flow/ t-mass/Teqwave MW 300/500 digital, Non-haz, Zone 2, transmitter housing, electronic compartment.Details
71185788T-DAT moduleDetails
71323010Module housing, 300/500, ExUsage: transmitter housing, electronic compartment. Consists of: module cartridge incl. interconnection board.Details
71323011Module box, 300, Non-hazUsage: transmitter housing, electronic compartment. Consists of: module cartridge incl. interconnection board.Details
71323005ribbon cable assemblyUsage: Promag/Promass 300/500, t-mass/Teqwave MW 300, transmitter housing.Details
71323073Terminal Block AssemblyUsage: transmitter housing Alu/hygienic, connection compartment. Option A = HART, PROFIBUS PA, FOUNDATION Fieldbus. Consists of: 1x connection terminal 2-Pol., 1x connection terminal 3-Pol., 1x connection terminal 4-Pol.Details
71323074Terminal Block AssemblyUsage: transmitter housing Alu/hygienic, connection compartment. Option B = EtherNet, PROFINET. Consists of: 1x connection terminal 3-Pol., 1x connection terminal 4-Pol.Details
71327818Terminal Block AssemblyUsage: transmitter housing Alu/hygienic, connection compartment. Option C = PROFIBUS DP, Modbus RS485. Consists of: 1x connection terminal 2-Pol., 1x connection terminal 3-Pol., 1x connection terminal 4-Pol.Details
71323075Terminal Block AssemblyUsage: transmitter housing Alu/cast, connection compartment. Option A = HART, PROFIBUS PA, FOUNDATION Fieldbus, Profinet APL, Modbus TCP APL. Consists of: 2x connection terminal 2-Pol., 1x connection terminal 4-Pol.Details
71323076Terminal Block AssemblyUsage: transmitter housing Alu/cast, connection compartment. Option B = EtherNet, PROFINET. Consists of: 2x connection terminal 2-Pol.Details
71327819Terminal Block AssemblyUsage: transmitter housing Alu/cast, connection compartment. Option C = PROFIBUS DP, Modbus RS485. Consists of: 2x connection terminal 2-Pol., 1x connection terminal 4-Pol.Details
71323079Terminal Block AssemblyUsage: transmitter housing Alu/cast, connection compartment with remote display DKX001. Consists of: 1x connection terminal 4-Pol.Details
71323016Cover AssemblyUsage: Promag/Promass/Prosonic Flow/t-mass/ Teqwave MW 300, Prosonic Flow 500, transmitter housing Alu, Non-haz. Promag/Promass 300, Promag/Promass/Prosonic Flow 500, transmitter housing Alu, Ex. Consists of: cover sight glass, Alu, O-Ring 110.7x3.53 HNBR.Details
71323017Cover AssemblyUsage: Promass/Prosonic Flow/t-mass 300, transmitter housing Alu, Non-haz. Promass 300, Promag/Promass/Prosonic Flow 500, transmitter housing Alu, Ex. Consists of: cover sight glass, Alu, O-Ring 110,7x3,53 FVMQ, -50oC/-58oF.Details

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

   

Measuring principle video

Click to play

Source: public information from the Endress+Hauser website

28 models · click to collapse
promass f300(91 条)→

数据摘自 Endress+Hauser 操作手册,含状态信号、可能原因与维修指导。

Municipal Wastewater Treatment

Municipal Wastewater Treatment · Mass Flow Meter — Application Case

Application Context

the inlet, biological and outlet stages of a municipal plant is a typical Municipal Wastewater Treatment duty. The project started from Mass Flow Meter, focusing on direct mass flow and density measurement.

Process Constraints

effluent parameters drift and probes foul with sludge and biofilm, and high solids and corrosive fractions, with large diurnal flow swings only amplify it. The Mass Flow Meter specification must therefore cover choosing tube geometry by flow range, entrained gas and hygienic needs.

Delivery Approach

Delivery was handled as the flow range — flow solution matched to line size, medium and range. Execution centred on choosing tube geometry by flow range, entrained gas and hygienic needs, together with stable compliance with Grade 1A discharge limits and online data reporting.

Field Results

Operation shows the benefit clearly — no temperature or pressure compensation needed, making custody transfer more credible, with confidence in this measuring point improving markedly.

Food & Beverage

Food & Beverage · Mass Flow Meter — Application Case

Customer Profile

The typical setting in Food & Beverage is dosing, pasteurising, filling and CIP stages. The measuring point is Mass Flow Meter; the focus is direct mass flow and density measurement.

Key Difficulties

Conditions are syrups, dairy and beverages that scale easily, under strict hygienic requirements and, on top of that, frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, which a standard configuration cannot handle for long. The design therefore starts with choosing tube geometry by flow range, entrained gas and hygienic needs.

Implementation

The scope ran through the flow range: flow solution matched to line size, medium and range. Technically it hinges on choosing tube geometry by flow range, entrained gas and hygienic needs, and on these requirements: food-safety and hygienic design per 3-A / EHEDG.

Customer Benefit

In practice this means no temperature or pressure compensation needed, making custody transfer more credible, which cut the workload on the site maintenance team.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Mass Flow Meter — Application Case

Project Background

The project covers reactors, metering vessels and finished-product tanks. The work centres on Mass Flow Meter and the core task is direct mass flow and density measurement.

Operating Challenges

The medium and duty are characterised by highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. So Mass Flow Meter cannot be specified generically — it calls for choosing tube geometry by flow range, entrained gas and hygienic needs.

Solution

The Ainstru engineering team worked through the flow range: flow solution matched to line size, medium and range. The configuration involves choosing tube geometry by flow range, entrained gas and hygienic needs, with these requirements in view: Ex certification and GMP traceability of records.

Results

Since start-up the system has run steadily; the practical result is no temperature or pressure compensation needed, making custody transfer more credible.

Power & Energy

Power & Energy · Mass Flow Meter — Application Case

Project Overview

The site is boiler feedwater, turbine condensate and FGD/DeNOx systems. The customer wanted Mass Flow Meter properly configured on the existing plant, with the aim of direct mass flow and density measurement.

Technical Challenges

What actually causes trouble is high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. All of this means the Mass Flow Meter configuration has to involve choosing tube geometry by flow range, entrained gas and hygienic needs.

Configuration

Supply and installation were organised through the flow range: flow solution matched to line size, medium and range. On site this meant choosing tube geometry by flow range, entrained gas and hygienic needs, checked line by line against: compliance with power-industry codes and unit availability targets.

Performance

After commissioning the outcome is no temperature or pressure compensation needed, making custody transfer more credible, and the readings are now used for process tuning.