Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

8F2B Mass flowmeter

8F2B Mass flowmeter
Mass flowmeter
Configurable Models 13 models
Premium high-precision flowmeter, robust and durable, with easy-to-operate compact transmitter. It is the upgraded version of the 80F series, E+H's most highly regarded mass flowmeter, and holds the largest market share in the E+H 8 series of mass flowmeters, popular for its high precision and stability.

Field of application
The Promass F mass flowmeter is a renowned high-precision measuring instrument with a wide range of applications. The Promass F 200 flowmeter offers two-wire technology to meet industrial needs and can be seamlessly integrated into existing control systems. With intrinsically safe design (Ex ia), it ensures operational safety even in hazardous areas, and uses Heartbeat Technology for round-the-clock process safety.
The measuring principle is unaffected by the physical properties of the fluid itself, such as viscosity and density
Highest precision measurement of liquids and gases under different operating conditions

Device properties
Mass flow: measuring error ±0.1 %
Medium temperature up to +205 °C (+401 °F)
Nominal diameter: DN 8 ... 80 (3/8 ... 3")
Loop-powered technology
Robust two-compartment housing
Plant safety: extensive certifications (SIL, explosion-hazardous area

Advantages
Highest process safety - unaffected by vibration and harsh environments
Fewer process measuring points - multivariable measurement (flow, density, temperature)
Space-saving installation - no upstream or downstream straight pipe runs required
Convenient wiring - separate wiring compartment
Safe operation - backlit touch key control with display head, no need to open the cover
Comprehensive verification - Heartbeat Technology

Spare Parts & Accessories 48

48 spare parts · click to collapse
Order codeDescription
XPD0001-Mass flowmeter electronic insert 200Main electronic moduleEnquire
71108602I/O moduleNon-Ex, Ex. Current output, 4-20mA HART + 4-20mA analog. Usage: Promass 200/TB2, Prosonic Flow 200, Prowirl 200.Details
XPD0015-I/O module, 2-wire, 4-20mA, HART, ExNon-Ex, Ex. 1x current output HART.Enquire
XPD0016-I/O module, 2-wire, 4-20mA, HART, PFS, ExNon-Ex, Ex. 1x current output HART. 1x PFS= pulse/freq./switch output.Enquire
71164940I/O moduleNon-Ex, Ex. PROFIBUS PA, FOUNDATION Fieldbus. PFS=switch output. Version 2. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57. Usage: Promass 200, Prowirl 200, Promag 200.Details
71128617Overvoltage protector4-20mA HART. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/FMR54/FMR56/ FMR57, FMR60/FMR62/FMR67. Usage: Promass 200, Prosonic Flow 200, Promag 200, Prowirl 200.Details
71128619Overvoltage protector4-20mA HART, PROFIBUS PA, FOUNDATION Fieldbus, Imp./Freq./Switch output. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/FMR54/FMR56/ FMR57, FMR60/FMR62/FMR67. Usage: Promass 200, Prosonic Flow 200, Promag 200, Prowirl 200.Details
71109658Display module kit, SD02, push buttonsFor housing: GT18, GT19, GT20. Usage: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57. Usage: Promass 200/TB2, Prosonic Flow 200, t-mass 150, Promag 200, Prowirl 200. Consists of: Display SD02, helix cable, ribbon cable, connector cover.Details
XPD0024-Display moduleFor housing: GT18, GT19, GT20. Usage: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57, FMR60/62/67, FHX50. Promass 200/TB2, Prosonic Flow 200, t-mass 150, Promag 200, Prowirl 200. Consists of: Display SD02, helix cable, ribbon cable, connector cover.Enquire
71162152Display module kit, SD03, touch controlFor housing: GT18, GT19, GT20. Usage: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200. Consists of: Display SD03 illuminated, ribbon cable, connector cover.Details
XPD0025-Display moduleFor housing: GT18, GT19, GT20. Usage: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57, FMR60/62/67, FHX50. Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200. Consists of: Display SD03 illuminated, ribbon cable, connector cover.Enquire
71197334Transmitter FHX50Consists of: electronics, ribbon cable. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57. Usage: Promass200, Prowirl 200, Promag 200, Prosonic Flow 200.Details
71296840Plug connector M12, VATo connect FHX50. Usage: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57. Not for dust Ex. Usage: Prowirl 200, Promass 200, Promag 200, Prosonic Flow 200.Details
71206552CableConnection cable, shielded. Usage: FHX50, FHX50B.Details
71206554CableConnection cable, shielded. Usage: FHX50, FHX50B.Details
71206555CableConnection cable, shielded. Usage: FHX50, FHX50B.Details
71206556CableConnection cable, shielded. Usage: FHX50, FHX50B.Details
71110280Terminal kit 2-wire, I/O moduleConsists of: 4x terminal 2-pole, green. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.Details
71110281Aluminum coverMaterial: 316L. O-ring, EPDM, PTFE coated. Usage: FMP51/FMP52/FMP54/FMP55/ FMP56/FMP57, FMR51/FMR52/FMR53/ FMR54/FMR57, FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Prowirl 200.Details
71110282Aluminum coverMaterial: 316L. O-ring NBR, PTFE coated. Usage: FMP51/FMP52/FMP54/FMP55/ FMP56/FMP57, FMR51/FMR52/FMR53/ FMR54/FMR57, FMR62/FMR67, FHX50. Usage: Promass 200/TB2, Prosonic Flow 200, Prowirl 200.Details

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

   

Measuring principle video

Click to play

Source:Endress+Hauserpublic information from the website

13 models · click to collapse
Proline Prowirl F 200(66 条)→

数据摘自 Endress+Hauser 操作手册,含状态信号、可能原因与维修指导。

Municipal Wastewater Treatment

Municipal Wastewater Treatment · Mass Flow Meter — Application Case

Application Context

the inlet, biological and outlet stages of a municipal plant is a typical Municipal Wastewater Treatment duty. The project started from Mass Flow Meter, focusing on direct mass flow and density measurement.

Process Constraints

effluent parameters drift and probes foul with sludge and biofilm, and high solids and corrosive fractions, with large diurnal flow swings only amplify it. The Mass Flow Meter specification must therefore cover choosing tube geometry by flow range, entrained gas and hygienic needs.

Delivery Approach

Delivery was handled as the flow range — flow solution matched to line size, medium and range. Execution centred on choosing tube geometry by flow range, entrained gas and hygienic needs, together with stable compliance with Grade 1A discharge limits and online data reporting.

Field Results

Operation shows the benefit clearly — no temperature or pressure compensation needed, making custody transfer more credible, with confidence in this measuring point improving markedly.

Food & Beverage

Food & Beverage · Mass Flow Meter — Application Case

Customer Profile

The typical setting in Food & Beverage is dosing, pasteurising, filling and CIP stages. The measuring point is Mass Flow Meter; the focus is direct mass flow and density measurement.

Key Difficulties

Conditions are syrups, dairy and beverages that scale easily, under strict hygienic requirements and, on top of that, frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, which a standard configuration cannot handle for long. The design therefore starts with choosing tube geometry by flow range, entrained gas and hygienic needs.

Implementation

The scope ran through the flow range: flow solution matched to line size, medium and range. Technically it hinges on choosing tube geometry by flow range, entrained gas and hygienic needs, and on these requirements: food-safety and hygienic design per 3-A / EHEDG.

Customer Benefit

In practice this means no temperature or pressure compensation needed, making custody transfer more credible, which cut the workload on the site maintenance team.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Mass Flow Meter — Application Case

Project Background

The project covers reactors, metering vessels and finished-product tanks. The work centres on Mass Flow Meter and the core task is direct mass flow and density measurement.

Operating Challenges

The medium and duty are characterised by highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. So Mass Flow Meter cannot be specified generically — it calls for choosing tube geometry by flow range, entrained gas and hygienic needs.

Solution

The Ainstru engineering team worked through the flow range: flow solution matched to line size, medium and range. The configuration involves choosing tube geometry by flow range, entrained gas and hygienic needs, with these requirements in view: Ex certification and GMP traceability of records.

Results

Since start-up the system has run steadily; the practical result is no temperature or pressure compensation needed, making custody transfer more credible.

Power & Energy

Power & Energy · Mass Flow Meter — Application Case

Project Overview

The site is boiler feedwater, turbine condensate and FGD/DeNOx systems. The customer wanted Mass Flow Meter properly configured on the existing plant, with the aim of direct mass flow and density measurement.

Technical Challenges

What actually causes trouble is high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. All of this means the Mass Flow Meter configuration has to involve choosing tube geometry by flow range, entrained gas and hygienic needs.

Configuration

Supply and installation were organised through the flow range: flow solution matched to line size, medium and range. On site this meant choosing tube geometry by flow range, entrained gas and hygienic needs, checked line by line against: compliance with power-industry codes and unit availability targets.

Performance

After commissioning the outcome is no temperature or pressure compensation needed, making custody transfer more credible, and the readings are now used for process tuning.