Technical Data
CompareGas
| Measuring Principle | Coriolis |
| Product headline | Flowmeter with minimized total cost of ownership with easy-to-use operation concept. Measurement of liquids and gases in utility processes and basic applications. |
| Sensor features | Cost-effective general-purpose device – alternative to mechanical flowmeters. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space-saving installation – no in-/outlet run needs. Compact dual-tube sensor. Medium temperature up to +150 °C (+302 °F). Process pressure up to 100 bar (1450 psi). |
| Transmitter features | Optimum usability – display with touch screen (HART and Modbus RS485 communication only) or operation with mobile devices and SmartBlue app. Simple, time-saving commissioning – guided parameterization in advance and in the field. Integrated verification – Heartbeat Technology. System integration with HART, Modbus RS485, IO-Link. Flexible operation with app and optional display. |
| Nominal diameter range | DN 8 to 80 (⅜ to 3") |
| Wetted materials | Measuring tube: 1.4539 (904L) Connection: 1.4404 (316/316L) |
| Measured variables | Mass flow, temperature, Density (option), volume flow, corrected volume flow |
| Max. measurement error | Mass flow (liquid): ±0.5 % (standard), ±0.15 % (option) Mass flow (gas): ±0.75 % |
| Measuring range | 0 to 180 000 kg/h (0 to 6615 lb/min) |
| Max. process pressure | PN 40, Class 300, 40K |
| Medium temperature range | –40 to +150 °C (–40 to +302 °F) |
| Ambient temperature range | Standard: –20 to +60 °C (–4 to +140 °F) |
| Sensor housing material | Stainless steel 1.4301 (304) |
| Transmitter housing material | AlSi10Mg, coated |
| Degree of protection | Standard: IP66/67, Type 4X enclosure |
| Display/Operation | 2.4" LCD display with touch & auto rotate; Configuration and operation via Bluetooth technology possible |
| Outputs | 4-20 mA HART (active/passive), Pulse/frequency/switch output Modbus RS485, 4-20 mA |
| Digital communication | HART, MODBUS RS485, IO-Link |
| Power supply | DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area) |
| Hazardous area approvals | ATEX IECEx cCSAus EAC NEPSI INMETRO IND Ex JPN Uk Ex KC |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) |
| Pressure approvals and certificates | CRN, PED |
| Material certificates | 3.1 material |
| Hygienic approvals and certificates | EC 1935, FDA, GB4806, cGMP, 3-A |
Liquids
| Measuring Principle | Coriolis |
| Product headline | Flowmeter with minimized total cost of ownership with easy-to-use operation concept. Measurement of liquids and gases in utility processes and basic applications. |
| Sensor features | Cost-effective general-purpose device – alternative to mechanical flowmeters. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space-saving installation – no in-/outlet run needs. Compact dual-tube sensor. Medium temperature up to +150 °C (+302 °F). Process pressure up to 100 bar (1450 psi). |
| Transmitter features | Optimum usability – display with touch screen (HART and Modbus RS485 communication only) or operation with mobile devices and SmartBlue app. Simple, time-saving commissioning – guided parameterization in advance and in the field. Integrated verification – Heartbeat Technology. System integration with HART, Modbus RS485, IO-Link. Flexible operation with app and optional display. |
| Nominal diameter range | DN 8 to 80 (⅜ to 3") |
| Wetted materials | Measuring tube: 1.4539 (904L) Connection: 1.4404 (316/316L) |
| Measured variables | Mass flow, temperature, Density (option), volume flow, corrected volume flow |
| Max. measurement error | Mass flow (liquid): ±0.5 % (standard), ±0.15 % (option) Mass flow (gas): ±0.75% |
| Measuring range | 0 to 180 000 kg/h (0 to 6615 lb/min) |
| Max. process pressure | PN 40, Class 300, 40K |
| Medium temperature range | –40 to +150 °C (–40 to +302 °F) |
| Ambient temperature range | Standard: –20 to +60 °C (–4 to +140 °F) |
| Sensor housing material | Stainless steel 1.4301 (304) |
| Transmitter housing material | AlSi10Mg, coated |
| Degree of protection | Standard: IP66/67, Type 4X enclosure |
| Display/Operation | 2.4" LCD display with touch & auto rotate; Configuration and operation via Bluetooth technology possible |
| Outputs | 4-20 mA HART (active/passive), Pulse/frequency/switch output Modbus RS485, 4-20 mA |
| Digital communication | HART, MODBUS RS485, IO-Link |
| Power supply | DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area) |
| Hazardous area approvals | ATEX IECEx cCSAus EAC NEPSI INMETRO IND Ex JPN UK Ex KC |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) |
| Pressure approvals and certificates | CRN, PED |
| Material certificates | 3.1 material |
| Hygienic approvals and certificates | EC 1935, FDA, GB4806, cGMP, 3-A |
Benefits
Basic instrument with high cost-effectiveness: preferred alternative to conventional mechanical flowmeters
Fewer process measuring points: multivariable measurement (flow, density, temperature)
Space-saving installation: no inlet/outlet straight run requirement
Optimum operability: install the SmartBlue app on a mobile device for direct touchscreen operation
Simple, efficient commissioning: guided instrument configuration presets and on-site setup
Self-verification: uses Heartbeat Technology
Applications
The Promass K Coriolis mass flowmeter sensor is a cost-effective mass flow measurement solution. It reliably measures the flow of air, gases, fuel oil and water in basic applications. The hardware and software of the Promass K 10 are intuitively designed, greatly simplifying every step of the instrument throughout its entire lifecycle, from design to service, while ensuring Endress+Hauser quality. Heartbeat Technology ensures measurement reliability and extends the calibration interval of the instrument.
The measuring principle is unaffected by the physical properties of the fluid (e.g. viscosity or density)
Measurement of liquids and gases in utilities and basic applications
Device features
Dual measuring tube sensor, compact design
Maximum medium temperature: +150 °C (+302 °F)
Maximum process pressure: 100 bar (1450 psi)
Supports HART or Modbus RS485 system integration
Install the app and optional display unit for flexible operation
Spare Parts & Accessories 42
42 spare parts · click to collapse
| Order code | Description | |
|---|---|---|
| XPD0066- | sensor electronics moduleUsage: Promass 10. Consists of: ISEM (sensor electronic module) V312-02. | Enquire |
| XPD0067- | sensor electronics moduleUsage: Promass 10. Consists of: ISEM (sensor electronic module) V312-02. | Enquire |
| XPD0068- | sensor electronics moduleUsage: Promass 10. Consists of: ISEM (sensor electronic module) V312-05. | Enquire |
| XPD0069- | sensor electronics moduleUsage: Promass 10. Consists of: ISEM (sensor electronic module) V312-05. | Enquire |
| XPD0070- | sensor electronics moduleUsage: Promass 10. Consists of: ISEM (sensor electronic module) V312-04. | Enquire |
| XPD0071- | sensor electronics moduleUsage: Promass 10. Consists of: ISEM (sensor electronic module) V312-04. | Enquire |
| XPD0100- | ISEM, DN08-80, IO-Link, Promass 10, nExUsage: Promass 10. Consists of: ISEM (sensor electronic module) V312-02. | Enquire |
| XPD0076- | Electronic insert HART, 24VDC, nEx, polycarbonate, 10Electronic module E400. Usage: Promag 10, Promass 10. Consists of: Module cartridge, power supply module, I/O module | Enquire |
| XPD0077- | electronic plug-in moduleElectronic module E402. Usage: Promag 10, Promass 10. Consists of: Module cartridge, power supply module, I/O module | Enquire |
| XPD0078- | Power supply module Modbus, 24VDC, nEx, Polycarb., 10Electronic module E406. Usage: Promag 10, Promass 10. Consists of: Module cartridge, power supply module, I/O module | Enquire |
| XPD0079- | Modbus electronic module, 100-230VAC, nEx, polycarbonate, 10Electronic module E409. Usage: Promag 10, Promass 10. Consists of: Module cartridge, power supply module, I/O module | Enquire |
| XPD0080- | HART electronic module, 24 VDC, nEx, Alu, 10Electronic module E401. Usage: Promag 10, Promass 10. Consists of: Module cartridge, power supply module, I/O module | Enquire |
| XPD0081- | Power module, output moduleElectronic module E403. Usage: Promag 10, Promass 10. Consists of: Module cartridge, power supply module, I/O module | Enquire |
| XPD0082- | Power module, output moduleElectronic module E408. Usage: Promag 10, Promass 10. Consists of: Module cartridge, power supply module, I/O module | Enquire |
| XPD0083- | Power module, output moduleElectronic module E404. Usage: Promag 10, Promass 10. Consists of: Module cartridge, power supply module, I/O module | Enquire |
| XPD0084- | Power module, output moduleElectronic module E411. Usage: Promag 10, Promass 10. Consists of: Module cartridge, power supply module, I/O module | Enquire |
| XPD0096- | IO-Link, nEx, polycarbonate, 10Electronic module E415. Usage: Promag 10, Promass 10. Consists of: Module cartridge, main electronic mod., connection board. | Enquire |
| XPD0097- | IO-Link, nEx, alu, 10Electronic module E416. Usage: Promag 10, Promass 10. Consists of: Module cartridge, main electronic mod., connection board. | Enquire |
| XPD0087- | Display moduleUsage: Promag 10, Promass 10. Consists of: Display module A400. | Enquire |
| XPD0088- | Display moduleUsage: Promag 10, Promass 10. Consists of: Display module A401. | Enquire |
Configurator / Comparison
Measurement principle video
Click to playSource: Endress+Hauserpublic information from the website
8 documents · click to expand
BA Proline Promass K 10 Chinese
BA Proline Promass K 10 Chinese
BA Proline Promass K 10 Chinese
BA Proline Promass K 10 English
BA Proline Promass K 10 English
BA Proline Promass K 10 English
TI Proline Promass K 10 Chinese
TI Proline Promass K 10 English
Case Studies
Municipal Wastewater Treatment · Mass Flow Meter — Application Case
Application Context
the inlet, biological and outlet stages of a municipal plant is a typical Municipal Wastewater Treatment duty. The project started from Mass Flow Meter, focusing on direct mass flow and density measurement.
Process Constraints
effluent parameters drift and probes foul with sludge and biofilm, and high solids and corrosive fractions, with large diurnal flow swings only amplify it. The Mass Flow Meter specification must therefore cover choosing tube geometry by flow range, entrained gas and hygienic needs.
Delivery Approach
Delivery was handled as the flow range — flow solution matched to line size, medium and range. Execution centred on choosing tube geometry by flow range, entrained gas and hygienic needs, together with stable compliance with Grade 1A discharge limits and online data reporting.
Field Results
Operation shows the benefit clearly — no temperature or pressure compensation needed, making custody transfer more credible, with confidence in this measuring point improving markedly.
Food & Beverage · Mass Flow Meter — Application Case
Customer Profile
The typical setting in Food & Beverage is dosing, pasteurising, filling and CIP stages. The measuring point is Mass Flow Meter; the focus is direct mass flow and density measurement.
Key Difficulties
Conditions are syrups, dairy and beverages that scale easily, under strict hygienic requirements and, on top of that, frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, which a standard configuration cannot handle for long. The design therefore starts with choosing tube geometry by flow range, entrained gas and hygienic needs.
Implementation
The scope ran through the flow range: flow solution matched to line size, medium and range. Technically it hinges on choosing tube geometry by flow range, entrained gas and hygienic needs, and on these requirements: food-safety and hygienic design per 3-A / EHEDG.
Customer Benefit
In practice this means no temperature or pressure compensation needed, making custody transfer more credible, which cut the workload on the site maintenance team.
Chemical & Pharmaceutical · Mass Flow Meter — Application Case
Project Background
The project covers reactors, metering vessels and finished-product tanks. The work centres on Mass Flow Meter and the core task is direct mass flow and density measurement.
Operating Challenges
The medium and duty are characterised by highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. So Mass Flow Meter cannot be specified generically — it calls for choosing tube geometry by flow range, entrained gas and hygienic needs.
Solution
The Ainstru engineering team worked through the flow range: flow solution matched to line size, medium and range. The configuration involves choosing tube geometry by flow range, entrained gas and hygienic needs, with these requirements in view: Ex certification and GMP traceability of records.
Results
Since start-up the system has run steadily; the practical result is no temperature or pressure compensation needed, making custody transfer more credible.
Power & Energy · Mass Flow Meter — Application Case
Project Overview
The site is boiler feedwater, turbine condensate and FGD/DeNOx systems. The customer wanted Mass Flow Meter properly configured on the existing plant, with the aim of direct mass flow and density measurement.
Technical Challenges
What actually causes trouble is high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. All of this means the Mass Flow Meter configuration has to involve choosing tube geometry by flow range, entrained gas and hygienic needs.
Configuration
Supply and installation were organised through the flow range: flow solution matched to line size, medium and range. On site this meant choosing tube geometry by flow range, entrained gas and hygienic needs, checked line by line against: compliance with power-industry codes and unit availability targets.
Performance
After commissioning the outcome is no temperature or pressure compensation needed, making custody transfer more credible, and the readings are now used for process tuning.
Related Products
Endress+HauserMass flowmeter 8E3B
Endress+HauserCompact mass flowmeter
Endress+HauserMass flowmeter
Endress+HauserMass flowmeter
Endress+HauserFilling mass flowmeter
Endress+HauserCNG dispenser mass flowmeter 8FF
Endress+HauserMass flowmeter 8F5B
Endress+Hauser