Technical Data
CompareGas
| Measuring Principle | Coriolis |
| Product headline | The flowmeter for minimized cost of ownership combined with a compact field transmitter. Highly accurate measurement of liquids and gases for a wide range of standard applications. |
| Sensor features | Cost-effective – multi-purpose device; an alternative to conventional volumetric flowmeters. Fewer process measuring points – multivariable measurement (flow, temp). Space-saving installation – no in/outlet run needs. Compact dual-tube system. Medium temperature up to +140 °C (+284°F). |
| Transmitter features | Cost-effective – dedicated design for low-end applications and direct integration. Safe operation – display provides easy readable process information. Fully industry compliant – IEC/EN/NAMUR. 2-line backlit display without local operation. Device in compact version. |
| Nominal diameter range | DN 8 to 80 (⅜ to 3") |
| Wetted materials | Measuring tube: 1.4539 (904L) Connection: 1.4404 (316/316L) |
| Measured variables | Mass flow, volume flow, corrected volume flow |
| Max. measurement error | Mass flow (liquid): ±0.5 % Volume flow (liquid): ±0.5 % Mass flow (gas): ±1.0 % Density (liquid): ±0.0005 g/cm³ |
| Measuring range | 0 to 180 000 kg/h (0 to 6600 lb/min) |
| Max. process pressure | PN 100, Class 600, 63K |
| Medium temperature range | –40 to +140 °C (–40 to +284 °F) |
| Ambient temperature range | Standard: –20 to +60 °C (–4 to +140 °F) Option: –40 to +60 °C (–40 to +140 °F) |
| Sensor housing material | 1.4301 (304), corrosion resistant |
| Transmitter housing material | Powder-coated die-cast aluminium |
| Degree of protection | IP67, type 4X enclosure |
| Display/Operation | 2-line backlit display without push buttons (direct integration) Configuration via operating tools possible |
| Outputs | 3 outputs: 0-20 mA (active)/4-20 mA (active/passive) Pulse/frequency/switch output (passive) |
| Inputs | Status input |
| Digital communication | HART |
| Power supply | DC 16 to 62 V AC 85 to 260 V (45 to 65 Hz) AC 20 to 55 V (45 to 65 Hz) |
| Hazardous area approvals | ATEX, IECEx, FM, CSA, NEPSI, JPN |
| Other approvals and certificates | 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, marine PED, CRN 3-A |
| Product safety | CE, C-tick, EAC marking |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR |
| Marine approvals and certificates | Marine approval |
| Pressure approvals and certificates | PED, CRN |
| Material certificates | 3.1 material |
| Hygienic approvals and certificates | 3-A |
Liquids
| Measuring Principle | Coriolis |
| Product headline | The flowmeter for minimized cost of ownership combined with a compact field transmitter. Highly accurate measurement of liquids and gases for a wide range of standard applications. |
| Sensor features | Cost-effective – multi-purpose device; an alternative to conventional volumetric flowmeters. Fewer process measuring points – multivariable measurement (flow, temp). Space-saving installation – no in/outlet run needs. Compact dual-tube system. Medium temperature up to +140 °C (+284°F). |
| Transmitter features | Cost-effective – dedicated design for low-end applications and direct integration. Safe operation – display provides easy readable process information. Fully industry compliant – IEC/EN/NAMUR. 2-line backlit display without local operation. Device in compact version. |
| Nominal diameter range | DN 8 to 80 (⅜ to 3") |
| Wetted materials | Measuring tube: 1.4539 (904L) Connection: 1.4404 (316/316L) |
| Measured variables | Mass flow, volume flow, corrected volume flow |
| Max. measurement error | Mass flow (liquid): ±0.5 % Volume flow (liquid): ±0.5 % Mass flow (gas): ±1.0 % Density (liquid): ±0.0005 g/cm³ |
| Measuring range | 0 to 180 000 kg/h (0 to 6600 lb/min) |
| Max. process pressure | PN 100, Class 600, 63K |
| Medium temperature range | –40 to +140 °C (–40 to +284 °F) |
| Ambient temperature range | Standard: –20 to +60 °C (–4 to +140 °F) Option: –40 to +60 °C (–40 to +140 °F) |
| Sensor housing material | 1.4301 (304), corrosion resistant |
| Transmitter housing material | Powder-coated die-cast aluminium |
| Degree of protection | IP67, type 4X enclosure |
| Display/Operation | 2-line backlit display without push buttons (direct integration) Configuration via operating tools possible |
| Outputs | 3 outputs: 0-20 mA (active)/4-20 mA (active/passive) Pulse/frequency/switch output (passive) |
| Inputs | Status input |
| Digital communication | HART |
| Power supply | DC 16 to 62 V AC 85 to 260 V (45 to 65 Hz) AC 20 to 55 V (45 to 65 Hz) |
| Hazardous area approvals | ATEX, IECEx, FM, CSA, NEPSI, JPN |
| Product safety | CE, C-tick, EAC marking |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR |
| Marine approvals and certificates | Marine approval |
| Pressure approvals and certificates | PED, CRN |
| Material certificates | 3.1 material |
| Hygienic approvals and certificates | 3-A |
The Promass E series mass flowmeter uses the Coriolis principle, saves costs and has earned a good reputation. The flowmeter is equipped with a compact Promass 40 transmitter and is suitable for low-end measuring applications, providing high-precision liquid and gas flow measurement over a wide range of applications.
Advantages
Modular device and operating concept for greater efficiency.
One-piece flow measurement with fewer measuring points - multivariable measurement (flow, temperature)
Balanced twin-tube measuring system design with good vibration resistance.
Robust design, unaffected by external pipe forces.
No inlet/outlet straight runs required, simple installation.
Application areas
Coriolis measuring principle unaffected by the physical properties of the liquid, such as viscosity and density.
Extremely precise measurement of liquids and gases, e.g. additives, petroleum, greases, acids, alkalis, paints, varnishes and natural gas.
Fluid temperature up to +140 °C (+284 °F)
Process pressure up to 100 bar (1450 psi)
Mass flow measurement up to 180 t/h (6600 lb/min)
Hazardous area approvals
ATEX, FM, CSA, TIIS, IECEx, NEPSI
Spare Parts & Accessories 39
39 spare parts · click to collapse
| Order code | Description | |
|---|---|---|
| 50098557 | Power board220V = 85-260VAC | Details |
| 71039431 | Power boardHE = harsh environment 220V = 85-260VAC | Details |
| 50098558 | Explosion-proof power supply board220V = 85-260VAC | Details |
| 71097758 | explosion-proof amplifier board220V = 85-260VAC | Details |
| 50098565 | Power board24V = 20-55VAC / 16-62VDC | Details |
| 50098566 | Explosion-proof power supply boardKit P.s.b. 40/8X/65 20-55AC 16-62DC Ex | Details |
| 71097759 | Explosion-proof power supply board24V = 20-55VAC/16-62VDC | Details |
| 50094002 | fuseKit 10 fuses 250 VAC T800 MA | Details |
| 50094003 | fuseKit Bus/connec.b.5X/40/8X/65 field hous. | Details |
| 50106091 | explosion-proof amplifier boardLanguage: FR, ES, IT, NL, PT, DE, EN | Details |
| 50098302 | Intrinsically Safe Passive Current/Frequency Output ModuleKit com5X/40/8X/93/65 Iout pass/Freq.Exi | Details |
| 50098303 | Intrinsically Safe Active Current/Frequency Output ModuleKit com5X/40/8X/93/65 Iout act/Freq.Exi | Details |
| 50096757 | Explosion-proof current/frequency output moduleKit com50/40/80/90 curr/Freq.out Ex | Details |
| 50096759 | Explosion-proof current, frequency and status input/output moduleKit com50/51/40/80/90 I+F/stat.in+outEx | Details |
| 50098563 | Display module kit Pmass 40 <V1.06.00 | Details |
| 50108130 | Display module | Details |
| 50094016 | Field-mounted terminal board | Details |
| 50108139 | 5X/8X/40/65 Field-Mount Terminal BlockKit Termin.Block field hous. 5X/8X/40/65 | Details |
| 71003950 | S-Data module with settingSerialnumber is forceful required | Details |
| 50094026 | 5X/40/8X/65 Glass CoverKit Cover 5X/40/8X/65 with window | Details |
Configurator / Comparison
Accessories / Spare parts
Measuring principle video
Click to playManuals & Documents 8
All documents for this model8 documents · click to expand
Proline Promass 40 HART Description of Device Functions English
Proline Promass 40 HART Operating Instructions English
Proline Promass 40 English
Promass 40 Operating Instructions English
Proline Promass 40 HART Description of Device Functions English
技术资料 Proline Promass 40E Chinese
Proline Promass 40E Technical Information English
Proline Promass 40E Technical Information (SI units) English
Case Studies
Municipal Wastewater Treatment · Mass Flow Meter — Application Case
Application Context
the inlet, biological and outlet stages of a municipal plant is a typical Municipal Wastewater Treatment duty. The project started from Mass Flow Meter, focusing on direct mass flow and density measurement.
Process Constraints
effluent parameters drift and probes foul with sludge and biofilm, and high solids and corrosive fractions, with large diurnal flow swings only amplify it. The Mass Flow Meter specification must therefore cover choosing tube geometry by flow range, entrained gas and hygienic needs.
Delivery Approach
Delivery was handled as the flow range — flow solution matched to line size, medium and range. Execution centred on choosing tube geometry by flow range, entrained gas and hygienic needs, together with stable compliance with Grade 1A discharge limits and online data reporting.
Field Results
Operation shows the benefit clearly — no temperature or pressure compensation needed, making custody transfer more credible, with confidence in this measuring point improving markedly.
Food & Beverage · Mass Flow Meter — Application Case
Customer Profile
The typical setting in Food & Beverage is dosing, pasteurising, filling and CIP stages. The measuring point is Mass Flow Meter; the focus is direct mass flow and density measurement.
Key Difficulties
Conditions are syrups, dairy and beverages that scale easily, under strict hygienic requirements and, on top of that, frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, which a standard configuration cannot handle for long. The design therefore starts with choosing tube geometry by flow range, entrained gas and hygienic needs.
Implementation
The scope ran through the flow range: flow solution matched to line size, medium and range. Technically it hinges on choosing tube geometry by flow range, entrained gas and hygienic needs, and on these requirements: food-safety and hygienic design per 3-A / EHEDG.
Customer Benefit
In practice this means no temperature or pressure compensation needed, making custody transfer more credible, which cut the workload on the site maintenance team.
Chemical & Pharmaceutical · Mass Flow Meter — Application Case
Project Background
The project covers reactors, metering vessels and finished-product tanks. The work centres on Mass Flow Meter and the core task is direct mass flow and density measurement.
Operating Challenges
The medium and duty are characterised by highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. So Mass Flow Meter cannot be specified generically — it calls for choosing tube geometry by flow range, entrained gas and hygienic needs.
Solution
The Ainstru engineering team worked through the flow range: flow solution matched to line size, medium and range. The configuration involves choosing tube geometry by flow range, entrained gas and hygienic needs, with these requirements in view: Ex certification and GMP traceability of records.
Results
Since start-up the system has run steadily; the practical result is no temperature or pressure compensation needed, making custody transfer more credible.
Power & Energy · Mass Flow Meter — Application Case
Project Overview
The site is boiler feedwater, turbine condensate and FGD/DeNOx systems. The customer wanted Mass Flow Meter properly configured on the existing plant, with the aim of direct mass flow and density measurement.
Technical Challenges
What actually causes trouble is high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. All of this means the Mass Flow Meter configuration has to involve choosing tube geometry by flow range, entrained gas and hygienic needs.
Configuration
Supply and installation were organised through the flow range: flow solution matched to line size, medium and range. On site this meant choosing tube geometry by flow range, entrained gas and hygienic needs, checked line by line against: compliance with power-industry codes and unit availability targets.
Performance
After commissioning the outcome is no temperature or pressure compensation needed, making custody transfer more credible, and the readings are now used for process tuning.
Related Products
Endress+HauserMass flowmeter 8E3B
Endress+HauserCompact mass flowmeter
Endress+HauserMass flowmeter Promass K 10
Endress+HauserMass flowmeter
Endress+HauserMass flowmeter
Endress+HauserMass flowmeter
Endress+HauserMass flowmeter
Endress+Hauser