质量流量计 8E3B
Technical Data
CompareDensity
| Measuring Principle | Coriolis |
| Product Headline | Flowmeter with minimized total cost of ownership and a compact, easily accessible transmitter. Accurate measurement of liquids and gases for a wide range of standard applications. |
| Sensor features | Cost‐effective – multi‐purpose device; an alternative to conventional volumetric flowmeters. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Compact dual-tube sensor. Medium temperature up to +150 °C (+302 °F). |
| Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Process pressure up to 100 bar (1450 psi). Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. |
Density/Concentration
| Measuring Principle | Coriolis |
| Product headline | Flowmeter with minimized total cost of ownership and a compact, easily accessible transmitter. Accurate measurement of liquids and gases for a wide range of standard applications. |
| Sensor features | Cost‐effective – multi‐purpose device; an alternative to conventional volumetric flowmeters. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Compact dual-tube sensor. Medium temperature up to +150 °C (+302 °F). |
| Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Process pressure up to 100 bar (1450 psi). Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. |
| Nominal diameter range | DN 8 to 80 (⅜ to 3") |
| Wetted materials | Measuring tube: 1.4539 (904L) Connection: 1.4404 (316/316L) |
| Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration |
| Max. measurement error | Mass flow (liquid): ±0.15 % (standard), ±0.10 % (option) Volume flow (liquid): ±0.15 % Mass flow (gas): ±0.50 % Density (liquid): ±0.0005 g/cm³ |
| Measuring range | 0 to 180 000 kg/h (0 to 6615 lb/min) |
| Max. process pressure | PN 100, Class 600, 63K |
| Medium temperature range | –40 to +150 °C (–40 to +302 °F) |
| Ambient temperature range | Standard: –40 to +60 °C (–40 to +140 °F) Option: –50 to +60 °C (–58 to +140 °F) |
| Sensor housing material | 1.4301 (304), corrosion resistant |
| Transmitter housing material | AlSi10Mg, coated; stainless steel for hygenic transmitter design |
| Degree of protection | Standard: IP66/67, Type 4X enclosure IP69 |
| Display/Operation | 4-line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible Remote display available" |
| Outputs | 3 outputs: 4-20 mA HART (active/passive) 4-20 mA WirelessHART 4-20 mA (active/passive) Pulse/frequency/switch output (active/passive) Double pulse output (active/passive) Relay output |
| Inputs | Status input 4-20 mA input |
| Digital communication | HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, MODBUS TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA |
| Power supply | DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area) |
| Hazardous area approvals | ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex, KC |
| Product safety | CE, C-tick, EAC marking |
| Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) |
| Marine approvals and certificates | LR approval, DNV approval, ABS approval, BV approval, CCS approval |
| Pressure approvals and certificates | PED, CRN |
| Material certificates | 3.1 material |
| Hygienic approvals and certificates | 3-A, EHEDG, cGMP |
Gas
| Measuring Principle | Coriolis |
| Product headline | Flowmeter with minimized total cost of ownership and a compact, easily accessible transmitter. Accurate measurement of liquids and gases for a wide range of standard applications. |
| Sensor features | Cost‐effective – multi‐purpose device; an alternative to conventional volumetric flowmeters. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Compact dual-tube sensor. Medium temperature up to +150 °C (+302 °F). |
| Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Process pressure up to 100 bar (1450 psi). Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. |
| Nominal diameter range | DN 8 to 80 (⅜ to 3") |
| Wetted materials | Measuring tube: 1.4539 (904L) Connection: 1.4404 (316/316L) |
| Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration |
| Max. measurement error | Mass flow (liquid): ±0.15 % (standard), ±0.10 % (option) Volume flow (liquid): ±0.15 % Mass flow (gas): ±0.50 % Density (liquid): ±0.0005 g/cm³ |
| Measuring range | 0 to 180 000 kg/h (0 to 6615 lb/min) |
| Max. process pressure | PN 100, Class 600, 63K |
| Medium temperature range | –40 to +150 °C (–40 to +302 °F) |
| Ambient temperature range | Standard: –40 to +60 °C (–40 to +140 °F) Option: –50 to +60 °C (–58 to +140 °F) |
| Sensor housing material | 1.4301 (304), corrosion resistant |
| Transmitter housing material | AlSi10Mg, coated; stainless steel for hygenic transmitter design |
| Degree of protection | Standard: IP66/67, Type 4X enclosure IP69 |
| Display/Operation | 4-line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible Remote display available" |
| Outputs | 3 outputs: 4-20 mA HART (active/passive) 4-20 mA WirelessHART 4-20 mA (active/passive) Pulse/frequency/switch output (active/passive) Double pulse output (active/passive) Relay output |
| Inputs | Status input 4-20 mA input |
| Digital communication | HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, MODBUS TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA |
| Power supply | DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area) |
| Hazardous area approvals | ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex, KC |
| Product safety | CE, C-tick, EAC marking |
| Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) |
| Marine approvals and certificates | LR approval, DNV approval, ABS approval, BV approval, CCS approval |
| Pressure approvals and certificates | PED, CRN |
| Material certificates | 3.1 material |
| Hygienic approvals and certificates | 3-A, EHEDG, cGMP |
Liquids
| Measuring Principle | Coriolis |
| Product headline | Flowmeter with minimized total cost of ownership and a compact, easily accessible transmitter. Accurate measurement of liquids and gases for a wide range of standard applications. |
| Sensor features | Cost‐effective – multi‐purpose device; an alternative to conventional volumetric flowmeters. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Compact dual-tube sensor. Medium temperature up to +150 °C (+302 °F). |
| Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Process pressure up to 100 bar (1450 psi). Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. |
| Nominal diameter range | DN 8 to 80 (⅜ to 3") |
| Wetted materials | Measuring tube: 1.4539 (904L) Connection: 1.4404 (316/316L) |
| Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration |
| Max. measurement error | Mass flow (liquid): ±0.15 % (standard), ±0.10 % (option) Volume flow (liquid): ±0.15 % Mass flow (gas): ±0.50 % Density (liquid): ±0.0005 g/cm³ |
| Measuring range | 0 to 180 000 kg/h (0 to 6615 lb/min) |
| Max. process pressure | PN 100, Class 600, 63K |
| Medium temperature range | –40 to +150 °C (–40 to +302 °F) |
| Ambient temperature range | Standard: –40 to +60 °C (–40 to +140 °F) Option: –50 to +60 °C (–58 to +140 °F) |
| Sensor housing material | 1.4301 (304), corrosion resistant |
| Transmitter housing material | AlSi10Mg, coated; stainless steel for hygenic transmitter design |
| Degree of protection | Standard: IP66/67, Type 4X enclosure IP69 |
| Display/Operation | 4-line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible Remote display available" |
| Outputs | 3 outputs: 4-20 mA HART (active/passive) 4-20 mA WirelessHART 4-20 mA (active/passive) Pulse/frequency/switch output (active/passive) Double pulse output (active/passive) Relay output |
| Inputs | Status input 4-20 mA input |
| Digital communication | HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, MODBUS TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA |
| Power supply | DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area) |
| Hazardous area approvals | ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex, KC |
| Product safety | CE, C-tick, EAC marking |
| Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) |
| Marine approvals and certificates | LR approval, DNV approval, ABS approval, BV approval, CCS approval |
| Pressure approvals and certificates | PED, CRN |
| Material certificates | 3.1 material |
| Hygienic approvals and certificates | 3-A, EHEDG, cGMP |
Steam
| Measuring Principle | Coriolis |
| Product headline | Flowmeter with minimized total cost of ownership and a compact, easily accessible transmitter. Accurate measurement of liquids and gases for a wide range of standard applications. |
| Marine approvals and certificates | LR approval, DNV approval, ABS approval, BV approval |
The Promass E is robust and is an economical solution for long-term use in high-precision liquid and gas measurement in various standard applications across different industries. Combined with the compact transmitter, the Promass E 300 offers flexible operation and easy system integration: wiring on the same side of the instrument, remote display and improved connection options. Heartbeat Technology ensures compliance at all times and guarantees process safety.
Benefits
Economical: versatile instrument; preferred alternative to conventional volumetric flowmeters
Fewer process measuring points: multivariable measurement (flow, density, temperature)
Space-saving installation: no inlet/outlet straight run requirement
Complete view of process and diagnostic information: various user-configurable input/output combinations and fieldbuses
Reduced complexity and diversity: user-configurable input/output functions
Integrated verification: built-in Heartbeat Technology
Applications
The measuring principle is unaffected by the physical properties of the fluid (e.g. viscosity and density).
High-precision measurement of liquids and gases in standard applications, with broad applicability.
Device features
Compact dual measuring tube sensor
Medium temperature: max. +150 °C (+302 °F)
Process pressure: max. 100 bar (1450 psi)
Compact dual-compartment housing with up to 3 inputs/outputs
Backlit display, touch key operation and WLAN access
Remote display unit available
E+H Product Model Configuration Tool
Please enter the product model to configure
Product comparison
Please enter the product models to compare in the fields below; up to three products can be compared
Technical documentation
Technical data
Documents/Manuals/Software
Accessories/Spare parts
Measurement principle video
Source: Endress+Hauserpublic information from the website
Related Models
| Model | Name |
|---|---|
| 8E3B08-AAIBAEAFAASAD2SHA1+AK | 8E3B08-AAIBAEAFAASAD2SHA1+AK |
| 8E3B08-BBDBAEAFAASAD2SHA1+AK | 8E3B08-BBDBAEAFAASAD2SHA1+AK |
| 8E3B15-AAIBAEAFAASAD2SHA1+AK | 8E3B15-AAIBAEAFAASAD2SHA1+AK |
| 8E3B15-BBDBAEAFAASAD2SHA1+AK | 8E3B15-BBDBAEAFAASAD2SHA1+AK |
| 8E3B25-AAIBAEAFAASAD2SHA1+AK | 8E3B25-AAIBAEAFAASAD2SHA1+AK |
| 8E3B25-BBDBAEAFAASAD2SHA1+AK | 8E3B25-BBDBAEAFAASAD2SHA1+AK |
| 8E3B40-AAIBAEAFAASAD2SHA1+AK | 8E3B40-AAIBAEAFAASAD2SHA1+AK |
| 8E3B40-BBDBAEAFAASAD2SHA1+AK | 8E3B40-BBDBAEAFAASAD2SHA1+AK |
| 8E3B40-BDEBAEAFADSAAASAA1 | 8E3B40-BDEBAEAFADSAAASAA1 |
| 8E3B50-AAIBAEAFAASAD2SHA1+AK | 8E3B50-AAIBAEAFAASAD2SHA1+AK |
| 8E3B50-BBDBAEAFAASAD2SHA1+AK | 8E3B50-BBDBAEAFAASAD2SHA1+AK |
| 8E3B50-BSIBAEAFAASAD2SHA2+AK | 8E3B50-BSIBAEAFAASAD2SHA2+AK |
| 8E3B80-AAIBAAAFAASAD2SHA1+AK | 8E3B80-AAIBAAAFAASAD2SHA1+AK |
| 8E3B80-AAIBAEAFAASAD2SHA1+AK | 8E3B80-AAIBAEAFAASAD2SHA1+AK |
| 8E3B80-BBDBAEAFAASAD2SHA1+AK | 8E3B80-BBDBAEAFAASAD2SHA1+AK |
Case Studies
Municipal Wastewater Treatment — Wastewater Treatment Plant · Mass Flow Meter Application Case
Project Background
Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Mass Flow Meter.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Mass Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage — Food Production Line · Mass Flow Meter Application Case
Project Background
Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Mass Flow Meter.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Mass Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical — Reactors and Storage Tanks · Mass Flow Meter Application Case
Project Background
Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Mass Flow Meter.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Mass Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy — Power Plant Boiler and Turbine · Mass Flow Meter Application Case
Project Background
Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Mass Flow Meter.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Mass Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.