CCS120 Analog Total Chlorine SensorDiscontinued

CCS120 Analog Total Chlorine Sensor
Total Chlorine Sensor CCS120Discontinued
Configurable Models 1 models
hygienic sensors for all water and wastewater applications Sanitary sensors suitable for all water and sewage applications
Compare

Disinfection

Measuring Principle Total chlorine
Application Potable water,Process water, Waste water, pools
Characteristic Amperometric measurement of total chlorine.
Measuring range 0,1 - 10ppm total chlorine; pH 6,5 - 9,5
Measuring principle - Total chlorine consists of free chlorine (HOCl, OCl) and bounded chlorine (chloramines).
- A constant polarisation voltage between working and counter electrode instigates the electrochemical reaction.
- Only slightly pH dependent.
Design Closed amperometric two electrode sensor for continuous measurement of total chlorine.
Material Sensor shaft : PVC
Membrane cap : PPE
Dimension Diameter : appr. 25mm
Length : 210mm
Process temperature 5°C - 45°C
Process pressure 0bar - 3bar
Temperature sensor Including NTC-temperature sensor.
Connection TOP68 plug-in head

CCS120 analog sensor is used for the standard measurement of total chlorine. Reliable measurements are transmitted even when flow or conductivity fluctuations occur, control the disinfection circuit and ensure that the water is free of bacteria. At the same time, sensor calibration and maintenance intervals are long, reducing maintenance costs.

 

advantage

stable operating conditions.

prefabricated film cap for easy film replacement

When the flow rate exceeds 30l/h, the measurement is not affected by the flow rate

 

Application areas

CCS120 for total chlorine measurement:

 

Drinking water and process water

-Water treatment process and water supply network

-disinfection process monitoring, control and optimization

Sewage Treatment Plant

-Sewage Outlet Disinfection Monitoring and Control

-Waste water utilization

Utilities

-Sterilization process measurement

 

 

 

Accessories/Spare Parts

Source:Endress Hauserwebsite public information

Measuring principle video

Click to play

Spare Parts & Accessories 8

8 spare parts · click to collapse
Order codeDescription
71412917Kit CCS120/120D, Maintenance KitContent: Electrolyte 50 ml/ 1.69 fl.oz. 2x membrane capDetails
71412916Kit CCS120/120D, electrolyte 50 mlContent: Electrolyte 50 ml/ 1.69 fl.oz.Details
51516343Electrolyte, Total Chlorine Sensor CCS120Electrolyte,Total Chlorine Sensor CCS120Details
51517284Maintenance Kit, CCS120two membrane caps, electrolyteDetails
51517204Connection cable between CCS120 and CCE benchtop instrumentConnection cable,CCS120,CCE-station, 1mDetails
71105209Viton O-ring2 pieces, replacement for silicone ringDetails
50003987*** Junction Box VBMwith 10 high-impedance terminals Protection class: IP65 Dimensions: 125 x 80 x 55 mm (L x W x H)Details
71257946Handheld DPD Colorimetric Calibrator PF-3colorimetric measurement of free and total chlorine 0,05 - 6mg/l Disinfection, drinking and process water hand held photometer, IP67-graded, with cuvettes, DPD, according to ISO 7393 delivery in plastic case, test kit for free and total chlorine included hand-held photometer for calibration and verification of disinfection loopsDetails

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products
1 models · click to collapse
All documents for this model
8 documents · click to expand
BA

Operating Instructions CCS120 English

28 pages
Preview
TI

技术资料 Liquisys M CCM223/253 Chinese

Rev. 1413 24 pages
Preview
TI

技术资料 Liquisys M CCM223/253 Chinese

Rev. 1311 20 pages
Preview
TI

技术资料 CCS120 Chinese

Rev. 0706 8 pages
Preview
TI

Technical Information CCM 223/ English

Rev. 1413 24 pages
Preview
TI

Technical Information CCM 223/ English

Rev. 1311 22 pages
Preview
TI

Technical Information CCM 223/ English

12 pages
Preview
TI

Technical Information CCS120 English

8 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · sterilize — Application Case

Customer Profile

The typical setting in Municipal Wastewater Treatment is the inlet, biological and outlet stages of a municipal plant. The measuring point is sterilize; the focus is monitoring and controlling disinfectant dosing and efficacy.

Key Difficulties

Conditions are high solids and corrosive fractions, with large diurnal flow swings and, on top of that, effluent parameters drift and probes foul with sludge and biofilm, which a standard configuration cannot handle for long. The design therefore starts with matching monitoring points to the disinfection route (chlorine, UV, ozone).

Implementation

The scope ran through the analyser range: selecting as part of a complete water-analysis system. Technically it hinges on matching monitoring points to the disinfection route (chlorine, UV, ozone), and on these requirements: stable compliance with Grade 1A discharge limits and online data reporting.

Customer Benefit

In practice this means on-demand dosing, lowering both by-products and cost, which cut the workload on the site maintenance team.

Food & Beverage

Food & Beverage · sterilize — Application Case

Project Background

The project covers dosing, pasteurising, filling and CIP stages. The work centres on sterilize and the core task is monitoring and controlling disinfectant dosing and efficacy.

Operating Challenges

The medium and duty are characterised by syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. So sterilize cannot be specified generically — it calls for matching monitoring points to the disinfection route (chlorine, UV, ozone).

Solution

The Ainstru engineering team worked through the analyser range: selecting as part of a complete water-analysis system. The configuration involves matching monitoring points to the disinfection route (chlorine, UV, ozone), with these requirements in view: food-safety and hygienic design per 3-A / EHEDG.

Results

Since start-up the system has run steadily; the practical result is on-demand dosing, lowering both by-products and cost.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · sterilize — Application Case

Project Overview

The site is reactors, metering vessels and finished-product tanks. The customer wanted sterilize properly configured on the existing plant, with the aim of monitoring and controlling disinfectant dosing and efficacy.

Technical Challenges

What actually causes trouble is highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. All of this means the sterilize configuration has to involve matching monitoring points to the disinfection route (chlorine, UV, ozone).

Configuration

Supply and installation were organised through the analyser range: selecting as part of a complete water-analysis system. On site this meant matching monitoring points to the disinfection route (chlorine, UV, ozone), checked line by line against: Ex certification and GMP traceability of records.

Performance

After commissioning the outcome is on-demand dosing, lowering both by-products and cost, and the readings are now used for process tuning.

Power & Energy

Power & Energy · sterilize — Application Case

Site Conditions

This is a Power & Energy customer whose plant is at boiler feedwater, turbine condensate and FGD/DeNOx systems. The main task was monitoring and controlling disinfectant dosing and efficacy.

The Problem

The difficulty lies in high temperature and pressure with both steam and saline water; at the same time drift under high temperature and pressure, with very costly unplanned outages. Specification therefore means matching monitoring points to the disinfection route (chlorine, UV, ozone).

What We Did

We took a analyser range approach — selecting as part of a complete water-analysis system. Delivery was built around matching monitoring points to the disinfection route (chlorine, UV, ozone), with point-by-point checks on: compliance with power-industry codes and unit availability targets.

Operating Outcome

In service the system performs as intended — on-demand dosing, lowering both by-products and cost, with routine maintenance falling noticeably.