CCS120 Analog Total Chlorine Sensor

CCS120 Analog Total Chlorine Sensor

Total Chlorine Sensor CCS120

Configurable Models 1 models
hygienic sensors for all water and wastewater applications Sanitary sensors suitable for all water and sewage applications
Compare

Disinfection

Measuring Principle Total chlorine
Application Potable water,Process water, Waste water, pools
Characteristic Amperometric measurement of total chlorine.
Measuring range 0,1 - 10ppm total chlorine; pH 6,5 - 9,5
Measuring principle - Total chlorine consists of free chlorine (HOCl, OCl) and bounded chlorine (chloramines).
- A constant polarisation voltage between working and counter electrode instigates the electrochemical reaction.
- Only slightly pH dependent.
Design Closed amperometric two electrode sensor for continuous measurement of total chlorine.
Material Sensor shaft : PVC
Membrane cap : PPE
Dimension Diameter : appr. 25mm
Length : 210mm
Process temperature 5°C - 45°C
Process pressure 0bar - 3bar
Temperature sensor Including NTC-temperature sensor.
Connection TOP68 plug-in head

CCS120 analog sensor is used for the standard measurement of total chlorine. Reliable measurements are transmitted even when flow or conductivity fluctuations occur, control the disinfection circuit and ensure that the water is free of bacteria. At the same time, sensor calibration and maintenance intervals are long, reducing maintenance costs.

 

advantage

stable operating conditions.

prefabricated film cap for easy film replacement

When the flow rate exceeds 30l/h, the measurement is not affected by the flow rate

 

Application areas

CCS120 for total chlorine measurement:

 

Drinking water and process water

-Water treatment process and water supply network

-disinfection process monitoring, control and optimization

Sewage Treatment Plant

-Sewage Outlet Disinfection Monitoring and Control

-Waste water utilization

Utilities

-Sterilization process measurement

 

 

Technical Information

 

technical parameters

 

Documentation/Manuals/Software

 

Accessories/Spare Parts

Source:Endress Hauserwebsite public information

Model Name
CCS120-AS0 模拟式总氯传感器
Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · Disinfection Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Disinfection.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Disinfection for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · Disinfection Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Disinfection.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Disinfection for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · Disinfection Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Disinfection.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Disinfection for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · Disinfection Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Disinfection.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Disinfection for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.