Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

CLM253 Liquisys M

CLM253 Liquisys M
Liquisys M CLM253
Configurable Models 20 models
Liquisys CLM253 is a standard transmitter for all analog conductivity sensors. It improves your operational safety thanks to continuous plausibility, process and sensor checks. Select from numerous hardware and software modules, such as relays or fieldbus communication, to adapt it exactly to your measuring task. This modularity also allows you to upgrade the transmitter at any time. A simple menu and calibration make configuration and operation fast and easy.
Compare

Conductivity

Measuring Principle Conductive
Application Water, waste water, process
Characteristic 4-wire transmitter with a two-line display
Design Conductivity transmitter in a PC/ABS-field housing
Material PC/ABS
Dimension 247x170x115 mm
Temperature sensor Display and current output
Ex certification No
Ingress protection IP65
Input One-channel transmitter
Output / communication 0/4-20mA, Hart, Profibus.
Certificates, declarations and approvals CSA Gen. Purpose.

The Liquisys CLM253 is a standard transmitter for all analog conductivity sensors. Continuous plausibility, process and sensor checks increase operational safety. No matter which of the numerous hardware and software modules you choose, such as relays and bus communication, it adapts perfectly to the measuring task. It also allows the transmitter to be upgraded at any time, and its simple menus and factory calibration make configuration and operation fast and convenient.

Advantages
Greater operational safety: continuous process checking system, user-defined alarm settings, calibration plausibility checks
Extensive functions: conductivity, resistivity and concentration measurement, ultrapure water monitoring in accordance with USP and EP
Convenient operation and service: intuitive user interface, simple calibration, manual contact control
Reduced maintenance: automatic cleaning function triggered by alarm and limit switches (with Chemoclean)
Suitable for a wide range of applications: numerous expansion options such as P(ID) controllers, timers, etc., for all processes

Application areas
The Liquisys CLM253 transmitter can be used with various analog conductivity sensors and is suitable for non-hazardous area measurement in the following industries and utilities:
Chemical industry
Food & beverage
Life sciences
Power & energy
Water & wastewater
Primary materials & metallurgy
The Liquisys CLM253 uses the following communication protocols and interfaces:
0/4...20 mA
HART
PROFIBUS DP

 

Spare Parts & Accessories 37

37 spare parts · click to collapse
Order codeDescription
51501068KIT CXM253 Instrument PanelKIT CXM253 housing coverDetails
71071446Kit CxM253: Front foil + 6 key liftersDetails
51501073CXM253 Internally Mounted ComponentKIT CXM253 Internal housing partsDetails
51502184Transmitter connection headDetails
51501072CXM253 Mounting Base PlateKIT CXM253 bottom of housingDetails
51501069Mounting hingeKIT hingesDetails
51501087CXM253 Grounding Terminal BlockKIT CXM253 Ground terminal stripDetails
51501079CXM223 Terminal Block Power SupplyKIT CXM253 terminal strip power supplyDetails
51501074CXM253 Flat CableKIT CXM253 Ribbon cablesDetails
50086842LIQUISYS transmitter standpipe mounting kitfor mounting the field-transmitters on horizontal or vertical pipes (max. diam. 60 mm). Material: stainless steel V2ADetails
51501210CLM2x3 Main BoardKIT CLM2x3 Central module I1 conductiveDetails
51501213CLM2X3 Conductive ModuleKIT CLM2X3 Conductive modul I1 HARTDetails
51501212CLM2X3 Conductive ModuleKIT CLM2X3 Conductive module I2Details
51501214CLM2X3 Conductive ModuleKIT CLM2X3 Conductive module I2 HARTDetails
51501215CLM2X3 Main ModuleKIT CLM2X3 cen. module Profibus PA cond.Details
51502502Kit CLM2X3 Main ModuleKit CLM2X3 central module ProfibusDPkondDetails
71134726Kit CLM2x3: Central module, conductivity, PBDP; H/W2.1xContent: 1x Central module Profibus DP Module name: LSCP-DP qualifired from H/W 2.10Details
71134732Relay moduleContent: 1x Relay module Profibus DP 2x Relay, 1x Current input DP connection qualified from H/W 2.10Details
51501216CLM2x3 Inductive ModuleKIT CLM2x3 inductive module I1Details
51501219CLM2x3 Inductive ModuleKIT CLM2x3 Inductive modul I1 HARTDetails

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

Accessories / Spare parts

 

A

Source:Endress+Hauserpublic information from the website

Measuring principle video

Click to play
336 models · click to collapse
All documents for this model
9 documents · click to expand
BA

Liquisys M CLM223/253 操作手册 Chinese

Rev. 1515 116 pages
Preview
BA

Liquisys M CLM223/253 Operating Instructions English

Rev. 1515 122 pages
Preview
BA

Operating Instructions Liquisys M CXM223/253 PROFIBUS English

Rev. 1311 40 pages
Preview
BA

Operating Instructions Liquisys M CLM 223/253 English

Rev. 1311 108 pages
Preview
BA

Operating Instructions Liquisys M CXM223/253 HART English

HART 35 pages
Preview
TI

技术资料 Liquisys M CLM223/253 Chinese

Rev. 1514 20 pages
Preview
TI

技术资料 Liquisys M CLM223/253 Chinese

Rev. 1311 20 pages
Preview
TI

Liquisys M CLM223/253 Technical Information English

Rev. 1514 20 pages
Preview
TI

Technical Information LIQUISYS English

Rev. 1311 20 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · conductivity — Application Case

Customer Profile

The typical setting in Municipal Wastewater Treatment is the inlet, biological and outlet stages of a municipal plant. The measuring point is conductivity; the focus is measuring conductivity to judge water purity or chemical concentration.

Key Difficulties

Conditions are high solids and corrosive fractions, with large diurnal flow swings and, on top of that, effluent parameters drift and probes foul with sludge and biofilm, which a standard configuration cannot handle for long. The design therefore starts with choosing two- or four-electrode cells by range and corrosivity.

Implementation

The scope ran through the analyser range: selecting as part of a complete water-analysis system. Technically it hinges on choosing two- or four-electrode cells by range and corrosivity, and on these requirements: stable compliance with Grade 1A discharge limits and online data reporting.

Customer Benefit

In practice this means stable concentration control and less reagent and discharge waste, which cut the workload on the site maintenance team.

Food & Beverage

Food & Beverage · conductivity — Application Case

Project Background

The project covers dosing, pasteurising, filling and CIP stages. The work centres on conductivity and the core task is measuring conductivity to judge water purity or chemical concentration.

Operating Challenges

The medium and duty are characterised by syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. So conductivity cannot be specified generically — it calls for choosing two- or four-electrode cells by range and corrosivity.

Solution

The Ainstru engineering team worked through the analyser range: selecting as part of a complete water-analysis system. The configuration involves choosing two- or four-electrode cells by range and corrosivity, with these requirements in view: food-safety and hygienic design per 3-A / EHEDG.

Results

Since start-up the system has run steadily; the practical result is stable concentration control and less reagent and discharge waste.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · conductivity — Application Case

Project Overview

The site is reactors, metering vessels and finished-product tanks. The customer wanted conductivity properly configured on the existing plant, with the aim of measuring conductivity to judge water purity or chemical concentration.

Technical Challenges

What actually causes trouble is highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. All of this means the conductivity configuration has to involve choosing two- or four-electrode cells by range and corrosivity.

Configuration

Supply and installation were organised through the analyser range: selecting as part of a complete water-analysis system. On site this meant choosing two- or four-electrode cells by range and corrosivity, checked line by line against: Ex certification and GMP traceability of records.

Performance

After commissioning the outcome is stable concentration control and less reagent and discharge waste, and the readings are now used for process tuning.

Power & Energy

Power & Energy · conductivity — Application Case

Site Conditions

This is a Power & Energy customer whose plant is at boiler feedwater, turbine condensate and FGD/DeNOx systems. The main task was measuring conductivity to judge water purity or chemical concentration.

The Problem

The difficulty lies in high temperature and pressure with both steam and saline water; at the same time drift under high temperature and pressure, with very costly unplanned outages. Specification therefore means choosing two- or four-electrode cells by range and corrosivity.

What We Did

We took a analyser range approach — selecting as part of a complete water-analysis system. Delivery was built around choosing two- or four-electrode cells by range and corrosivity, with point-by-point checks on: compliance with power-industry codes and unit availability targets.

Operating Outcome

In service the system performs as intended — stable concentration control and less reagent and discharge waste, with routine maintenance falling noticeably.