CLD134 Conductivity compact device

CLD134  Conductivity compact device
Smartec S CLD134
Configurable Models 20 models
Toroidal conductivity measuring system for hygienic and sterile applications
Compare

Conductivity

Measuring Principle Inductive
Application Food, beverage, dairies, breweries and pharmaceutical industries, biotechnology
Characteristic Specifically intended for use in hygienic applications and especially suitable for following applications:
Phase separation, control of CIP, concentration control, product monitoring, leakage monitoring
Measuring range 100 µS/cm to 2000 mS/cm
Cell constant k : 6.3 1/cm
Measuring principle Inductive conductivity measurement
Design Hygienic design with FDA certified virgin PEEK body including all hygienic certifications
Material In contact with medium: Virgin PEEK
Process temperature Max. 125 °C (max. 257 °F)
For sterilization: up to 150 °C for max. 60 min
(up to 302 °F for max. 60 min)
Process pressure 12 bar abs up to 90 °C
(174 psi abs up to 194 °F)
Temperature sensor Pt 1000
Connection Dairy pipe, aseptic-fitting, Clamp ISO 2852, SMS-2", Varivent N DN 40-125, Neumo Biocontrol D50
Ingress protection IP67
Output / communication Conductivity, concentration and temperature. 0/4 to 20 mA, HART, Profibus
Certificates, declarations and approvals nspection certificate 3.1, EN10204
Surface roughness test ISO4287/Ra (≤ 0,8 µm)
Bio reactivity test USP Class VI
US Food Contact Materials FDA CFR 21
EU Food Contact Materials (EG) 1935/2004
CN Food Contact Materials GB 4806
EHEDG EL Class I, 3-A

Field of application
Smartec CLD134 is a measuring system for inductive conductivity in the food & beverage and life sciences industries. The combination of a transmitter and a sensor is interference-free and especially easy-to-use. It meets the highest hygienic and sterile demands thanks to its food-grade virgin PEEK body, its jointless and creviceless design and its hygienic certificates. Smartec CLD134 is therefore the ideal package to ensure the highest safety and quality of your products and processes.
The hygienic Smartec CLD134 measures toroidal conductivity in food & beverage and life science applications:
Phase separation of product/water and product/product mixtures in pipe systems
Control of CIP processes in the return channel
Concentration control in remaking of CIP cleaning agents
Product monitoring in pipe systems, bottling plants, quality assurance
Leakage monitoring
It features the following protocols and interfaces:
0/4...20mA
HART
PROFIBUS DP
PROFIBUS PA

Benefits
Unique hygienic design avoids recontamination
With all hygienic certificates required in hygienic and sterile applications
Certified biocompatibility according to USP class VI
Compliant with EG 2023/2006 and 1935/2004
Suitable for cleaning-in-place (CIP) and sterilization-in-place (SIP)
Durable thanks to encapsulated, jointless design

 

Conductivity:

Measuring Principle Inductive
Application Food, beverage, dairies, breweries and pharmaceutical industries, biotechnology
Characteristic Specifically intended for use in hygienic applications and especially suitable for following applications:
Phase separation, control of CIP, concentration control, product monitoring, leakage monitoring
Measuring range 100 µS/cm to 2000 mS/cm
Cell constant k : 6.3 1/cm
Measuring principle Inductive conductivity measurement
Design Hygienic design with FDA certified virgin PEEK body including all hygienic certifications
Material In contact with medium: Virgin PEEK
Process temperature Max. 125 °C (max. 257 °F)
For sterilization: up to 150 °C for max. 60 min
(up to 302 °F for max. 60 min)
Process pressure 12 bar abs up to 90 °C
(174 psi abs up to 194 °F)
 
Temperature sensor Pt 1000
Connection Dairy pipe, aseptic-fitting, Clamp ISO 2852, SMS-2", Varivent N DN 40-125, Neumo Biocontrol D50
Ingress protection IP67
Output / communication Conductivity, concentration and temperature. 0/4 to 20 mA, HART, Profibus
Additional certifications FDA, EHEDG, 3A
Biological reactivity USP class VI part <87> and <88>
EC Regulation No. 1935/2004

Measuring principle video

Click to play

Spare Parts & Accessories 41

41 spare parts · click to collapse
Order codeDescription
71020487sensorKit CLD134, version MV5, spare sensorDetails
71020488sensorDetails
71020489sensorDetails
71020490sensorDetails
71020491sensorDetails
71020492sensorDetails
71020493***Kit CLD134 version AA5, sensor USP 87Details
71020495Kit CLD134 version CS1, sensor USP 87Details
71020496Kit CLD134 version VA4, sensor USP 87Details
71020497Kit CLD134 version BC5, sensor USP 87Details
71025965Kit CLD134 Main Module, 1 OutputDetails
71025968Output moduleDetails
71025969Kit CLD134 Main Module 1 Output + HARTDetails
71025970Kit CLD134 main module, 2 outputs + HARTDetails
71025971Kit CLD134 Main Module Profibus PADetails
71025972Kit CLD134 Main Module Profibus DPDetails
71134734CLD134: Central Processing UnitContent: 1x Central module Profibus DP Module name: LSCP-DP qualified from H/W 2.10Details
71134735CLD134: Terminal ModuleContent: 1x Terminal module Profibus DP Module name : LSKB qualified for central mod. from H/W 2.10Details
51501206MKIC Conductivity Transmitter KitKit MKIC Conductivity transmitterDetails
71161133Transmitter boardDetails

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products
346 models · click to collapse
All documents for this model
12 documents · click to expand
BA

Smartec CLD134 操作手册 Chinese

Rev. 1618 96 pages
Preview
BA

BA Smartec CLD132/134 Chinese

Rev. 1523 44 pages
Preview
BA

Smartec CLD18 Chinese

Rev. 0820 48 pages
Preview
BA

Smartec CLD134 Operating Instructions English

Rev. 1618 104 pages
Preview
BA

BA Smartec CLD132/134 English

Rev. 1523 44 pages
Preview
BA

Operating Instructions Smartec S CLD134 English

Rev. 1311 88 pages
Preview
BA

Smartec CLD18 English

Rev. 0820 52 pages
Preview
BA

Operating Instructions Smartec S CLD132 Profibus- PA/-DP English

PROFIBUS-PA 44 pages
Preview
TI

技术资料 Smartec CLD134 Chinese

Rev. 1315 24 pages
Preview
TI

技术资料 Smartec S CLD134 Chinese

Rev. 0108 24 pages
Preview
TI

Smartec CLD134 Technical Information English

Rev. 1418 24 pages
Preview
TI

Technical Information Smartec S CLD134 English

Rev. 0108 24 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · conductivity — Application Case

Customer Profile

The typical setting in Municipal Wastewater Treatment is the inlet, biological and outlet stages of a municipal plant. The measuring point is conductivity; the focus is measuring conductivity to judge water purity or chemical concentration.

Key Difficulties

Conditions are high solids and corrosive fractions, with large diurnal flow swings and, on top of that, effluent parameters drift and probes foul with sludge and biofilm, which a standard configuration cannot handle for long. The design therefore starts with choosing two- or four-electrode cells by range and corrosivity.

Implementation

The scope ran through the analyser range: selecting as part of a complete water-analysis system. Technically it hinges on choosing two- or four-electrode cells by range and corrosivity, and on these requirements: stable compliance with Grade 1A discharge limits and online data reporting.

Customer Benefit

In practice this means stable concentration control and less reagent and discharge waste, which cut the workload on the site maintenance team.

Food & Beverage

Food & Beverage · conductivity — Application Case

Project Background

The project covers dosing, pasteurising, filling and CIP stages. The work centres on conductivity and the core task is measuring conductivity to judge water purity or chemical concentration.

Operating Challenges

The medium and duty are characterised by syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. So conductivity cannot be specified generically — it calls for choosing two- or four-electrode cells by range and corrosivity.

Solution

The Ainstru engineering team worked through the analyser range: selecting as part of a complete water-analysis system. The configuration involves choosing two- or four-electrode cells by range and corrosivity, with these requirements in view: food-safety and hygienic design per 3-A / EHEDG.

Results

Since start-up the system has run steadily; the practical result is stable concentration control and less reagent and discharge waste.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · conductivity — Application Case

Project Overview

The site is reactors, metering vessels and finished-product tanks. The customer wanted conductivity properly configured on the existing plant, with the aim of measuring conductivity to judge water purity or chemical concentration.

Technical Challenges

What actually causes trouble is highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. All of this means the conductivity configuration has to involve choosing two- or four-electrode cells by range and corrosivity.

Configuration

Supply and installation were organised through the analyser range: selecting as part of a complete water-analysis system. On site this meant choosing two- or four-electrode cells by range and corrosivity, checked line by line against: Ex certification and GMP traceability of records.

Performance

After commissioning the outcome is stable concentration control and less reagent and discharge waste, and the readings are now used for process tuning.

Power & Energy

Power & Energy · conductivity — Application Case

Site Conditions

This is a Power & Energy customer whose plant is at boiler feedwater, turbine condensate and FGD/DeNOx systems. The main task was measuring conductivity to judge water purity or chemical concentration.

The Problem

The difficulty lies in high temperature and pressure with both steam and saline water; at the same time drift under high temperature and pressure, with very costly unplanned outages. Specification therefore means choosing two- or four-electrode cells by range and corrosivity.

What We Did

We took a analyser range approach — selecting as part of a complete water-analysis system. Delivery was built around choosing two- or four-electrode cells by range and corrosivity, with point-by-point checks on: compliance with power-industry codes and unit availability targets.

Operating Outcome

In service the system performs as intended — stable concentration control and less reagent and discharge waste, with routine maintenance falling noticeably.