Technical Data
CompareConductivity
| Measuring Principle | Inductive |
| Application | Chemical industry, process |
| Characteristic | Analog or digital, inductive conductivity sensor for standard, Ex and high-temperature applications |
| Measuring range | 2µS/cm to 2000 mS/cm |
| Measuring principle | Inductive conductivity measurement |
| Design | No direct contact with the media because of the sensor coating made of highly resistant material |
| Material | PEEK or PFA |
| Dimension | Electrode: Outside diameter: 47.5 mm (1.87 inch) Inside diameter: 15 mm (0.59 inch) Inside diameter (PEEK version): 15.5 mm (0.61 inch) |
| Process temperature | PEEK: max. 125°C (max. 260 °F) PFA: max. 110°C (max. 230 °F) |
| Process pressure | PEEK: max. 21 bar (max. 304.5 psi) PFA: max. 17 bar (max. 246.5 psi) |
| Temperature sensor | Integrated Pt1000 |
| Ex certification | ATEX, IECEx, NEPSI, FM, CSA, TIIS, EAC |
| Connection | Process connection: NPT1", DN50, AINSI, JIScable: fixed cable connection |
| Ingress protection | IP 68 / NEMA type 6 |
| Certificates, declarations and approvals | Calibration certification of the cell constant |
The Indumax CLS50D is an inductive conductivity sensor suitable for standard, hazardous and high-temperature environments. Thanks to the robust materials (PFA, PEEK), the sensor is insensitive to soiling and ensures reliable and repeatable performance even in corrosive media. Based on Memosens technology, the CLS50D achieves maximum process and data integrity through simple operation, is corrosion- and moisture-resistant and enables predictive maintenance.
Advantages
Durable, chemical-resistant, suitable for measurements under harsh operating conditions
Contamination-resistant materials prevent contamination
Wide temperature measuring range and corrosion-resistant materials make the sensor highly versatile
Reliable measurement based on effective connection monitoring
Long wiring distance does not affect measurement accuracy
Records sensor-specific parameters for convenient traceability
Explosion protection approval
Areas of application
The Indumax CLS50D measures toroidal conductivity and is suitable for:
Chemical industry:
- Concentration measurement of acids and bases
- Quality monitoring of chemical media in tanks and pipes
Food&beverage industry:
- Phase separation of medium/medium mixtures in pipes
Life sciences sector:
- Phase separation of medium/medium mixtures in pipes
Wastewater treatment industry:
- Inlet monitoring
Various international explosion protection approvals such as ATEX, FM, CSA, NEPSI, suitable for explosive hazardous areas
Spare Parts & Accessories 15
15 spare parts · click to collapse
| Order code | Description | |
|---|---|---|
| 71086368 | CLS50 CHEMRAZ O-ring | Details |
| 71086369 | Kit CLS50 >20081001: VITON O-ring | Details |
| 71086372 | PTFE sealing ring CLS50 DN50 | Details |
| 71086374 | Kit CLS50 ANSI+JIS >20081001: PTFE gasket | Details |
| 51500525 | CLS50 DN50 SS flange | Details |
| 51500527 | flange | Details |
| 51500934 | flange | Details |
| 51500935 | flange | Details |
| 51500936 | flange | Details |
| 51500937 | flange | Details |
| 50081902 | Calibration solution 74.0 µS/cm500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISO | Details |
| 50081903 | calibration solution500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISO. | Details |
| 50081904 | Calibration solution 1.406 mS/cm500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISO | Details |
| 50081905 | calibration solution500 ml, reference temperature 25oC. Precision solution referred to SRM to NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISO | Details |
| 50081906 | calibration solution500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISO | Details |
Configurator / Comparison
A
Source:Endress+Hauserwebsite public information
Measuring principle video
Click to playManuals & Documents 4
All documents for this modelCase Studies
Municipal Wastewater Treatment · conductivity — Application Case
Customer Profile
The typical setting in Municipal Wastewater Treatment is the inlet, biological and outlet stages of a municipal plant. The measuring point is conductivity; the focus is measuring conductivity to judge water purity or chemical concentration.
Key Difficulties
Conditions are high solids and corrosive fractions, with large diurnal flow swings and, on top of that, effluent parameters drift and probes foul with sludge and biofilm, which a standard configuration cannot handle for long. The design therefore starts with choosing two- or four-electrode cells by range and corrosivity.
Implementation
The scope ran through the analyser range: selecting as part of a complete water-analysis system. Technically it hinges on choosing two- or four-electrode cells by range and corrosivity, and on these requirements: stable compliance with Grade 1A discharge limits and online data reporting.
Customer Benefit
In practice this means stable concentration control and less reagent and discharge waste, which cut the workload on the site maintenance team.
Food & Beverage · conductivity — Application Case
Project Background
The project covers dosing, pasteurising, filling and CIP stages. The work centres on conductivity and the core task is measuring conductivity to judge water purity or chemical concentration.
Operating Challenges
The medium and duty are characterised by syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. So conductivity cannot be specified generically — it calls for choosing two- or four-electrode cells by range and corrosivity.
Solution
The Ainstru engineering team worked through the analyser range: selecting as part of a complete water-analysis system. The configuration involves choosing two- or four-electrode cells by range and corrosivity, with these requirements in view: food-safety and hygienic design per 3-A / EHEDG.
Results
Since start-up the system has run steadily; the practical result is stable concentration control and less reagent and discharge waste.
Chemical & Pharmaceutical · conductivity — Application Case
Project Overview
The site is reactors, metering vessels and finished-product tanks. The customer wanted conductivity properly configured on the existing plant, with the aim of measuring conductivity to judge water purity or chemical concentration.
Technical Challenges
What actually causes trouble is highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. All of this means the conductivity configuration has to involve choosing two- or four-electrode cells by range and corrosivity.
Configuration
Supply and installation were organised through the analyser range: selecting as part of a complete water-analysis system. On site this meant choosing two- or four-electrode cells by range and corrosivity, checked line by line against: Ex certification and GMP traceability of records.
Performance
After commissioning the outcome is stable concentration control and less reagent and discharge waste, and the readings are now used for process tuning.
Power & Energy · conductivity — Application Case
Site Conditions
This is a Power & Energy customer whose plant is at boiler feedwater, turbine condensate and FGD/DeNOx systems. The main task was measuring conductivity to judge water purity or chemical concentration.
The Problem
The difficulty lies in high temperature and pressure with both steam and saline water; at the same time drift under high temperature and pressure, with very costly unplanned outages. Specification therefore means choosing two- or four-electrode cells by range and corrosivity.
What We Did
We took a analyser range approach — selecting as part of a complete water-analysis system. Delivery was built around choosing two- or four-electrode cells by range and corrosivity, with point-by-point checks on: compliance with power-industry codes and unit availability targets.
Operating Outcome
In service the system performs as intended — stable concentration control and less reagent and discharge waste, with routine maintenance falling noticeably.
Related Products
Endress+HauserLiquisys M CLM223
Endress+HauserCondumax CLS21
Endress+HauserSmartec S CLD134
Endress+HauserCondumax CLS15D
Endress+HauserCondumax CLS19
Endress+HauserSmartec CLD18
Endress+HauserIndumax CLS50