Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

CLS19 Analog conductivity sensor

CLS19  Analog conductivity sensor
Condumax CLS19
Configurable Models 4 models
Conductive conductivity sensor for simple standard applications in pure and ultrapure water
Compare

Conductivity

Measuring Principle Conductive
Application Pure and ultrapure water
Characteristic 2-electrode conductivity cell for pure water applications.
Measuring range k=0,01: 0-20 µS/cm
k=0,1: 0-200 µS/cm
Measuring principle Conductive conductivity cell.
Design 2-electrode conductivity cell with coaxially arranged electrodes
Material Cell shaft: PES
Electrode: Stainless steel 1.4571
Dimension Electrode diameter: 16 mm
(0.62 inch)
Process temperature max. 60°C
max. 140°F
Process pressure max. 6 bar at 20°C
(max.87 psi at 68°F)
Temperature sensor Optional with integrated Pt100
Connection Process connection: NPT 1/2"
cable:4-pole DIN-connector with Pg9
Ingress protection IP65
Certificates, declarations and approvals Quality certification

Field of application
Condumax CLS19 measures conductivity in the low measuring ranges. It performs reliably and accurately in a wide range of applications. Designed for low maintenance and a long operating life, the sensor offers you best value for money.
Condumax CLS19 measures conductivity in pure and ultrapure water applications for the monitoring and control of:
Ion exchangers
Reverse osmosis
Cooling water
Distillation
Chip cleaning

Benefits
Reliable and accurate measuring values at low conductivities
Best price-performance ratio
Easy installation with threaded connection
Robust design for high durability
Different cell constants provide a wide measuring range

 

Conductivity:

Measuring Principle Conductive
Application Pure and ultrapure water
Characteristic 2-electrode conductivity cell for pure water applications.
Measuring range k=0,01: 0-20 µS/cm
k=0,1: 0-200 µS/cm
Measuring principle Conductive conductivity cell.
Design 2-electrode conductivity cell with coaxially arranged electrodes
Material Cell shaft: PES
Electrode: Stainless steel 1.4571
Dimension Electrode diameter: 16 mm
(0.62 inch)
Process temperature max. 60°C
max. 140°F
Process pressure max. 6 bar at 20°C
(max.87 psi at 68°F)
Temperature sensor Optional with integrated Pt100
Connection Process connection: NPT 1/2"
cable:4-pole DIN-connector with Pg9
Ingress protection IP65
Additional certifications Quality certification

Measuring principle video

Click to play

Spare Parts & Accessories 8

8 spare parts · click to collapse
Order codeDescription
50015632Cable connectorAlte Material-Nummer: 117234Details
50081902Calibration solution 74.0 µS/cm500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISODetails
50081903calibration solution500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISO.Details
50081904Calibration solution 1.406 mS/cm500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISODetails
50081905calibration solution500 ml, reference temperature 25oC. Precision solution referred to SRM to NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISODetails
50081906calibration solution500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISODetails
71042405316L flow-through bracketpolished, Connector medium: vertical/horizontal 6mm pipe --> Successor CYA21Details
CYA21-Compact flow-through mounting assembly CYA21Stainless steel flow-through assembly for mounting on analytical panels. Construction of analytical panels for applications within powerplants and the (petro-) chemical industry among others. Fits for applications up to 100oC at 16 bar. Robust stainless steel assembly; fit for applications at higher pressure and temperature rates; perfect for bypass installations; inclusive mounting kit.Enquire

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products
4 models · click to collapse
All documents for this model
7 documents · click to expand
BA

Condumax CLS19 Chinese

Rev. 0220 16 pages
Preview
BA

Condumax CLS19 English

Rev. 0220 16 pages
Preview
TI

Condumax CLS19 Chinese

Rev. 1321 8 pages
Preview
TI

技术资料 Condumax W CLS19 Chinese

Rev. 0308 8 pages
Preview
TI

Condumax CLS19 English

Rev. 1321 8 pages
Preview
TI

Technical Information CLS 19 English

Rev. 0308 8 pages
Preview
TI

Technical Information CLS 19 English

8 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · conductivity — Application Case

Customer Profile

The typical setting in Municipal Wastewater Treatment is the inlet, biological and outlet stages of a municipal plant. The measuring point is conductivity; the focus is measuring conductivity to judge water purity or chemical concentration.

Key Difficulties

Conditions are high solids and corrosive fractions, with large diurnal flow swings and, on top of that, effluent parameters drift and probes foul with sludge and biofilm, which a standard configuration cannot handle for long. The design therefore starts with choosing two- or four-electrode cells by range and corrosivity.

Implementation

The scope ran through the analyser range: selecting as part of a complete water-analysis system. Technically it hinges on choosing two- or four-electrode cells by range and corrosivity, and on these requirements: stable compliance with Grade 1A discharge limits and online data reporting.

Customer Benefit

In practice this means stable concentration control and less reagent and discharge waste, which cut the workload on the site maintenance team.

Food & Beverage

Food & Beverage · conductivity — Application Case

Project Background

The project covers dosing, pasteurising, filling and CIP stages. The work centres on conductivity and the core task is measuring conductivity to judge water purity or chemical concentration.

Operating Challenges

The medium and duty are characterised by syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. So conductivity cannot be specified generically — it calls for choosing two- or four-electrode cells by range and corrosivity.

Solution

The Ainstru engineering team worked through the analyser range: selecting as part of a complete water-analysis system. The configuration involves choosing two- or four-electrode cells by range and corrosivity, with these requirements in view: food-safety and hygienic design per 3-A / EHEDG.

Results

Since start-up the system has run steadily; the practical result is stable concentration control and less reagent and discharge waste.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · conductivity — Application Case

Project Overview

The site is reactors, metering vessels and finished-product tanks. The customer wanted conductivity properly configured on the existing plant, with the aim of measuring conductivity to judge water purity or chemical concentration.

Technical Challenges

What actually causes trouble is highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. All of this means the conductivity configuration has to involve choosing two- or four-electrode cells by range and corrosivity.

Configuration

Supply and installation were organised through the analyser range: selecting as part of a complete water-analysis system. On site this meant choosing two- or four-electrode cells by range and corrosivity, checked line by line against: Ex certification and GMP traceability of records.

Performance

After commissioning the outcome is stable concentration control and less reagent and discharge waste, and the readings are now used for process tuning.

Power & Energy

Power & Energy · conductivity — Application Case

Site Conditions

This is a Power & Energy customer whose plant is at boiler feedwater, turbine condensate and FGD/DeNOx systems. The main task was measuring conductivity to judge water purity or chemical concentration.

The Problem

The difficulty lies in high temperature and pressure with both steam and saline water; at the same time drift under high temperature and pressure, with very costly unplanned outages. Specification therefore means choosing two- or four-electrode cells by range and corrosivity.

What We Did

We took a analyser range approach — selecting as part of a complete water-analysis system. Delivery was built around choosing two- or four-electrode cells by range and corrosivity, with point-by-point checks on: compliance with power-industry codes and unit availability targets.

Operating Outcome

In service the system performs as intended — stable concentration control and less reagent and discharge waste, with routine maintenance falling noticeably.