CLD18 Compact conductivity device

CLD18  Compact conductivity device
Smartec CLD18
Configurable Models 14 models
Toroidal conductivity measuring system for hygienic applications
Compare

Conductivity

Measuring Principle Inductive
Application Food and beverage industries
Characteristic Specifically intended for use in beverage industry applications and especially suitable for:
Phase separation, control of CIP, concentration control, product monitoring, leakage monitoring
Measuring range 200 µS/cm to 1000 mS/cm
Cell constant k: 11.0 1/cm
Measuring principle Inductive conductivity measurement
Design Hygienic design with FDA certified virgin PEEK
Material Sensor: PEEK
Process connection 1.4435 (316L)
Seal: EPDM
Process temperature -10 °C to 110 °C (14 °F to 230 °F)
Sterilization: max. 130 °C at 6 bar abs up to 60 min
(Max. 266 °F at 87 psi up to 60 min)
Process pressure 13 bar abs up to 50 °C (188.5 psi up to 122 °F)
7.75 bar abs at 110 °C (112 psi at 230 °F)
6.0 bar abs at 130 °C for max. 60 minutes
(87 psi at 266 °F for max. 60 minutes)
Temperature sensor Pt 1000 (class B)
Connection Dairy pipe, aseptic-fitting DN40 and DN50, Clamp 2"
ISO 2852, SMS-2", Varivent N DN 40-125
Thread G1 1/2 SS, G1 1/2 PVC , Union nut 2 1/4 Inch PVC
Ingress protection IP69
Output / communication 0/4...20mA
IO-Link (option)
Certificates, declarations and approvals Inspection certificate 3.1, EN10204
US Food Contact Materials FDA CFR 21
EU Food Contact Materials (EG) 1935/2004
CN Food Contact Materials GB 4806
EHEDG EL Class I, 3-A

Field of application
Smartec CLD18 is the cost-effective solution for all applications in beverage plants where small tubes are used and where the toroidal measurement is used as a switch function. The combination of a transmitter and a sensor is interference-free, easy-to-use and features a hygienic design that protects your products and processes from contamination. Smartec CLD18 ensures the Overall Equipment Effectiveness (OEE) of your plant thanks to fast and reliable CIP and optional IO-Link protocol.
The hygienic Smartec CLD18 measures toroidal conductivity in beverage applications:
Control of CIP processes in the return channel
Concentration control in remaking of CIP cleaning agents
Product monitoring in pipe systems, bottling plants
Beer - Push water interphase
Beer - Water cut for brewing lines
Leakage monitoring
It features the following protocols and interfaces:
0/4...20mA
IO-Link (optional)

Benefits
Unique hygienic design avoids contamination
3-A approval
Compliant with EG 2023/2006 and 1935/2004
Suitable for cleaning-in-place (CIP)
Smart and easy integration into your plant infrastructure thanks to optional IO-Link protocol
Compact design permits installation in small tubes without restricting the flow

 

conductivity:

Measuring Principle Inductive
Application Food and beverage industries
Characteristic Specifically intended for use in beverage industry applications and especially suitable for:
Phase separation, control of CIP, concentration control, product monitoring, leakage monitoring
Measuring range 200 µS/cm to 1000 mS/cm
Cell constant k: 11.0 1/cm
Measuring principle Inductive conductivity measurement
Design Hygienic design with FDA certified virgin PEEK
Material Sensor: PEEK
Process connection 1.4435 (316L)
Seal: EPDM
Process temperature -10 °C to 110 °C (14 °F to 230 °F)
Sterilization: max. 130 °C at 6 bar abs up to 60 min
(Max. 266 °F at 87 psi up to 60 min)
Process pressure 13 bar abs up to 50 °C (188.5 psi up to 122 °F)
7.75 bar abs at 110 °C (112 psi at 230 °F)
6.0 bar abs at 130 °C for max. 60 minutes
(87 psi at 266 °F for max. 60 minutes)
Temperature sensor Pt 1000 (class B)
Connection Dairy pipe, aseptic-fitting DN40 and DN50, Clamp 2"
ISO 2852, SMS-2", Varivent N DN 40-125
Thread G1 1/2 SS, G1 1/2 PVC , Union nut 2 1/4 Inch PVC
Ingress protection IP69
Output / communication 0/4...20mA IO-Link (option)
Additional certifications 3A, FDA, EHEDG
EC Regulation No. 1935/2004

Measuring principle video

Click to play

Spare Parts & Accessories 9

9 spare parts · click to collapse
Order codeDescription
71228583CLD18 upper plastic housingDetails
71228584CLD18 Upper Stainless Steel HousingDetails
71526058Kit CLD18 Upgrade IO-LinkDetails
50081902Calibration solution 74.0 µS/cm500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISODetails
50081903calibration solution500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISO.Details
50081904Calibration solution 1.406 mS/cm500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISODetails
50081905calibration solution500 ml, reference temperature 25oC. Precision solution referred to SRM to NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISODetails
50081906calibration solution500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISODetails
51506592Adapter 2 1/4" for SMARTEC-TDetails

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products
14 models · click to collapse
All documents for this model
6 documents · click to expand
BA

Smartec CLD18 Chinese

Rev. 0820 48 pages
Preview
BA

Smartec CLD18 Chinese

Rev. 0221 48 pages
Preview
BA

Smartec CLD18 English

Rev. 0820 52 pages
Preview
BA

Smartec CLD18 English

Rev. 0221 48 pages
Preview
TI

Smartec CLD18 Chinese

Rev. 0621 16 pages
Preview
TI

Smartec CLD18 English

Rev. 0621 16 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · conductivity — Application Case

Customer Profile

The typical setting in Municipal Wastewater Treatment is the inlet, biological and outlet stages of a municipal plant. The measuring point is conductivity; the focus is measuring conductivity to judge water purity or chemical concentration.

Key Difficulties

Conditions are high solids and corrosive fractions, with large diurnal flow swings and, on top of that, effluent parameters drift and probes foul with sludge and biofilm, which a standard configuration cannot handle for long. The design therefore starts with choosing two- or four-electrode cells by range and corrosivity.

Implementation

The scope ran through the analyser range: selecting as part of a complete water-analysis system. Technically it hinges on choosing two- or four-electrode cells by range and corrosivity, and on these requirements: stable compliance with Grade 1A discharge limits and online data reporting.

Customer Benefit

In practice this means stable concentration control and less reagent and discharge waste, which cut the workload on the site maintenance team.

Food & Beverage

Food & Beverage · conductivity — Application Case

Project Background

The project covers dosing, pasteurising, filling and CIP stages. The work centres on conductivity and the core task is measuring conductivity to judge water purity or chemical concentration.

Operating Challenges

The medium and duty are characterised by syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. So conductivity cannot be specified generically — it calls for choosing two- or four-electrode cells by range and corrosivity.

Solution

The Ainstru engineering team worked through the analyser range: selecting as part of a complete water-analysis system. The configuration involves choosing two- or four-electrode cells by range and corrosivity, with these requirements in view: food-safety and hygienic design per 3-A / EHEDG.

Results

Since start-up the system has run steadily; the practical result is stable concentration control and less reagent and discharge waste.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · conductivity — Application Case

Project Overview

The site is reactors, metering vessels and finished-product tanks. The customer wanted conductivity properly configured on the existing plant, with the aim of measuring conductivity to judge water purity or chemical concentration.

Technical Challenges

What actually causes trouble is highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. All of this means the conductivity configuration has to involve choosing two- or four-electrode cells by range and corrosivity.

Configuration

Supply and installation were organised through the analyser range: selecting as part of a complete water-analysis system. On site this meant choosing two- or four-electrode cells by range and corrosivity, checked line by line against: Ex certification and GMP traceability of records.

Performance

After commissioning the outcome is stable concentration control and less reagent and discharge waste, and the readings are now used for process tuning.

Power & Energy

Power & Energy · conductivity — Application Case

Site Conditions

This is a Power & Energy customer whose plant is at boiler feedwater, turbine condensate and FGD/DeNOx systems. The main task was measuring conductivity to judge water purity or chemical concentration.

The Problem

The difficulty lies in high temperature and pressure with both steam and saline water; at the same time drift under high temperature and pressure, with very costly unplanned outages. Specification therefore means choosing two- or four-electrode cells by range and corrosivity.

What We Did

We took a analyser range approach — selecting as part of a complete water-analysis system. Delivery was built around choosing two- or four-electrode cells by range and corrosivity, with point-by-point checks on: compliance with power-industry codes and unit availability targets.

Operating Outcome

In service the system performs as intended — stable concentration control and less reagent and discharge waste, with routine maintenance falling noticeably.