Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

CLS15D CondumaxDiscontinued

CLS15D Condumax
Condumax CLS15DDiscontinued
Configurable Models 4 models
Condumax CLS15D is the digital solution for conductivity measurement in the low measuring ranges. It performs reliably and accurately in a wide range of applications - even in hazardous areas. Designed for low maintenance and a long operating life, the sensor offers best value for money. Condumax CLS15D is not the latest Memosens generation. To get information on the new Memosens CLS15E sensor with extended functionality, click here.
Compare

Conductivity

Measuring Principle
Application Measurement in pure and ultrapure water range, monitoring of ion exchangers, reverse osmosis, distillation, chip cleaning
Characteristic Analog or digital 2-electrode conductivity sensors
Measuring range k=0,01: 0.04 to 20 µS/cm
k=0,1: 0.10 to 200 µS/cm
Measuring principle Conductive conductivity cell with polished stainless steel electrodes
Design 2-electrode conductivity cell with coaxially arranged electrodes, electropolished
Material Electrode: stainless steel 1.4435
Electrode shaft: PES
Dimension Electrode diameter: 16 mm (0.63 inch)
Electrode length: appr. 55 mm (2.17 inch)
Process temperature Threaded with fixed cable:
-20 to 100 °C (-4 to 212 °F)
Threaded with plug-in head:
-20 to 120 °C (-4 to 248 °F)
Sterilization: max. 140 °C (284 °F) for 30 minutes
Process pressure 13 bar at 20 °C (188 psi at 68 °F)
1 bar at 120 °C (14 psi at 248 °F)
Temperature sensor NTC 30K
Ex certification ATEX, NEPSI, FM, CSA
Connection Process: 1/2" and 3/4" NPT, Clamp 1 1/2"
Cable: Memosens connector
Ingress protection IP68
Certificates, declarations and approvals Calibration certification of the cell constante, material certification 3.1

Condumax CLS15D is a digital solution for low-range conductivity measurement, suitable for a wide range of applications and operating reliably and accurately even in hazardous areas. It offers low maintenance, a long service life and an excellent price-performance ratio. Based on Memosens digital technology, CLS15D achieves maximum process and data integrity through simple operation. Resistant to corrosion and moisture, it can be laboratory calibrated for sensor pre-maintenance.

Benefits

  • Reliable and accurate measurement of low-conductivity media

  • Polished measuring surface, easy to clean

  • Sterilizable and heat-resistant

  • Quality certificate with independent cell constant

  • Sensor-specific parameters are recorded for easy traceability and pre-maintenance

  • Non-contact inductive signal transmission ensures maximum process safety

  • Simple maintenance strategy based on Memobase Plus for convenient data and sensor management

Application areas

  • The Condumax CLS15D conductivity sensor is used for conductivity measurement in pure and ultrapure water, for monitoring and control of:

  • Ion exchangers

  • Reverse osmosis

  • Cooling water

  • Distillation

  • Chip cleaning

  • The digital sensor can be used in power plants for:

  • Degassed conductivity

  • pH measurement using the differential conductivity method

  • Various international explosion protection approvals, such as ATEX and FM, for use in hazardous areas

Common models: CLS15D-A1A1 and CLS15D-B1A1

 

Spare Parts & Accessories 12

12 spare parts · click to collapse
Order codeDescription
50004381adapter fittingfor mounting of sensors with thread NPT 1/2".Details
50004738Mating Sleevefor conductivity cell installation into T-90-piece or cross piece DN 32Details
50004739Mating SleeveFor conductivity cell installation into T-90-piece or cross piece DN40Details
50004740Mating SleeveFor conductivity cell installation into T-90-piece or cross piece DN50Details
50081902Calibration solution 74.0 µS/cm500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISODetails
50081903calibration solution500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISO.Details
50081904Calibration solution 1.406 mS/cm500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISODetails
50081905calibration solution500 ml, reference temperature 25oC. Precision solution referred to SRM to NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISODetails
50081906calibration solution500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISODetails
71042405316L flow-through bracketpolished, Connector medium: vertical/horizontal 6mm pipe --> Successor CYA21Details
CYA21-Compact flow-through mounting assembly CYA21Stainless steel flow-through assembly for mounting on analytical panels. Construction of analytical panels for applications within powerplants and the (petro-) chemical industry among others. Fits for applications up to 100oC at 16 bar. Robust stainless steel assembly; fit for applications at higher pressure and temperature rates; perfect for bypass installations; inclusive mounting kit.Enquire
50066536threaded fittingfor cementing in cross / T-pieces DN 20Details

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

A

   

Measuring Principle Video

Click to play
4 models · click to collapse
All documents for this model
7 documents · click to expand
BA

Condumax CLS15D, CLS16D, CLS21D Chinese

Rev. 0722 28 pages
Preview
BA

Condumax CLS15D/16D/21D English

Rev. 0722 28 pages
Preview
TI

技术资料 Condumax CLS15, CLS15D Chinese

Rev. 1414 16 pages
Preview
TI

技术资料 Condumax CLS15, CLS15D Chinese

Rev. 1312 12 pages
Preview
TI

技术资料 Condumax CLS15/CLS15D Chinese

Rev. 0410 16 pages
Preview
TI

Technical Information Condumax CLS15/CLS15D English

Rev. 1414 16 pages
Preview
TI

Technical information Conductivity Sensor Condumax W CLS15 English

16 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · conductivity — Application Case

Customer Profile

The typical setting in Municipal Wastewater Treatment is the inlet, biological and outlet stages of a municipal plant. The measuring point is conductivity; the focus is measuring conductivity to judge water purity or chemical concentration.

Key Difficulties

Conditions are high solids and corrosive fractions, with large diurnal flow swings and, on top of that, effluent parameters drift and probes foul with sludge and biofilm, which a standard configuration cannot handle for long. The design therefore starts with choosing two- or four-electrode cells by range and corrosivity.

Implementation

The scope ran through the analyser range: selecting as part of a complete water-analysis system. Technically it hinges on choosing two- or four-electrode cells by range and corrosivity, and on these requirements: stable compliance with Grade 1A discharge limits and online data reporting.

Customer Benefit

In practice this means stable concentration control and less reagent and discharge waste, which cut the workload on the site maintenance team.

Food & Beverage

Food & Beverage · conductivity — Application Case

Project Background

The project covers dosing, pasteurising, filling and CIP stages. The work centres on conductivity and the core task is measuring conductivity to judge water purity or chemical concentration.

Operating Challenges

The medium and duty are characterised by syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. So conductivity cannot be specified generically — it calls for choosing two- or four-electrode cells by range and corrosivity.

Solution

The Ainstru engineering team worked through the analyser range: selecting as part of a complete water-analysis system. The configuration involves choosing two- or four-electrode cells by range and corrosivity, with these requirements in view: food-safety and hygienic design per 3-A / EHEDG.

Results

Since start-up the system has run steadily; the practical result is stable concentration control and less reagent and discharge waste.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · conductivity — Application Case

Project Overview

The site is reactors, metering vessels and finished-product tanks. The customer wanted conductivity properly configured on the existing plant, with the aim of measuring conductivity to judge water purity or chemical concentration.

Technical Challenges

What actually causes trouble is highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. All of this means the conductivity configuration has to involve choosing two- or four-electrode cells by range and corrosivity.

Configuration

Supply and installation were organised through the analyser range: selecting as part of a complete water-analysis system. On site this meant choosing two- or four-electrode cells by range and corrosivity, checked line by line against: Ex certification and GMP traceability of records.

Performance

After commissioning the outcome is stable concentration control and less reagent and discharge waste, and the readings are now used for process tuning.

Power & Energy

Power & Energy · conductivity — Application Case

Site Conditions

This is a Power & Energy customer whose plant is at boiler feedwater, turbine condensate and FGD/DeNOx systems. The main task was measuring conductivity to judge water purity or chemical concentration.

The Problem

The difficulty lies in high temperature and pressure with both steam and saline water; at the same time drift under high temperature and pressure, with very costly unplanned outages. Specification therefore means choosing two- or four-electrode cells by range and corrosivity.

What We Did

We took a analyser range approach — selecting as part of a complete water-analysis system. Delivery was built around choosing two- or four-electrode cells by range and corrosivity, with point-by-point checks on: compliance with power-industry codes and unit availability targets.

Operating Outcome

In service the system performs as intended — stable concentration control and less reagent and discharge waste, with routine maintenance falling noticeably.