Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

CLS13 Condumax

CLS13 Condumax
Condumax CLS13
Configurable Models 6 models
Condumax CLS13 is a robust conductivity sensor for steam/water cycles in power plants. It is optimized for low conductivities (even under very high temperatures and pressures) to protect your processes from deposits and corrosion. Low maintenance and simple to commission (large connection compartment), this is the ideal sensor for tough environments.
Compare

Conductivity

Measuring Principle Conductive
Application Process, power plant
Characteristic 2-electrode conductivity cell for high temperature applications.
Measuring range k=0,01: 0-20,0 µS/cm
k=0,1: 0-200,0 µS/cm
Measuring principle Coaxially arranged electrodes for high temperature applications
Design 2-electrode conductivity cell with coaxially arranged electrodes
Connection head and cooling body made of casting aluminium with fixed cable connection PG16
Material Electrode: 1.4571
Sealing: Kalrez, ceramic
Dimension Electrode diameter: 25 mm (0.984 inch)
Immersion depth: 50 to 115 mm (1.97 to 4.48 inch)
Weight: 3kg
Process temperature max. 250 °C (482 °F)
Process pressure max. 40 bar (580 psi)
Temperature sensor Integrated Pt100
Ex certification ATEX
Connection Process connection: G1"
Ingress protection IP67
Certificates, declarations and approvals Calibration certificate with cellconstant

The Condumax CLS13 is a stable conductivity sensor for measuring in steam/water cycles in power plants, especially suitable for low-conductivity measurement applications (high temperature, high pressure), ensuring that the process is protected from corrosion. Low maintenance and easy commissioning (large terminal compartment) make it the ideal choice for harsh operating conditions.

 

Advantages

Reliable and precise measurement of low-conductivity media

Best choice for high-temperature, high-pressure applications (temperature up to 250 °C)

Stainless steel body and removable external electrode for easy cleaning

Robust and durable

Quality certificate includes independent cell constant specification

 

Areas of application

The Condumax CLS13 can be used for conductivity measurement in steam/water cycles in the power&energy industry:

 

Condensate monitoring

Boiler feedwater monitoring

Boiler blowdown control

The sensor can be used for low-conductivity media measurement under high temperature and high pressure.

 

Various international explosion protection approvals such as ATEX and FM, suitable for explosive hazardous areas

Spare Parts & Accessories 11

11 spare parts · click to collapse
Order codeDescription
50012511insulating sleeveDetails
71603556CLS12/13 Outer SheathDetails
71603566CLS13 Seal KitDetails
50013937flat sealing gasketAlte Material-Nummer: 115731Details
50089330electrodeDetails
50089331electrodeDetails
50081902Calibration solution 74.0 µS/cm500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISODetails
50081903calibration solution500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISO.Details
50081904Calibration solution 1.406 mS/cm500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISODetails
50081905calibration solution500 ml, reference temperature 25oC. Precision solution referred to SRM to NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISODetails
50081906calibration solution500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISODetails

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

A

Source:Endress+Hauserwebsite public information

Measuring principle video

Click to play
6 models · click to collapse
All documents for this model
6 documents · click to expand
BA

BA Condumax CLS12/CLS13 Chinese

Rev. 0326 16 pages
Preview
BA

BA Condumax CLS12/CLS13 English

Rev. 0326 20 pages
Preview
TI

TI Condumax CLS13 Chinese

Rev. 1526 8 pages
Preview
TI

技术资料 Condumax W CLS13 Chinese

Rev. 0603 8 pages
Preview
TI

TI Condumax CLS13 English

Rev. 1526 8 pages
Preview
TI

Technical information Conductivity Sensor for High-Temperature Applications ConduMax W CLS 13 English

8 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · conductivity — Application Case

Customer Profile

The typical setting in Municipal Wastewater Treatment is the inlet, biological and outlet stages of a municipal plant. The measuring point is conductivity; the focus is measuring conductivity to judge water purity or chemical concentration.

Key Difficulties

Conditions are high solids and corrosive fractions, with large diurnal flow swings and, on top of that, effluent parameters drift and probes foul with sludge and biofilm, which a standard configuration cannot handle for long. The design therefore starts with choosing two- or four-electrode cells by range and corrosivity.

Implementation

The scope ran through the analyser range: selecting as part of a complete water-analysis system. Technically it hinges on choosing two- or four-electrode cells by range and corrosivity, and on these requirements: stable compliance with Grade 1A discharge limits and online data reporting.

Customer Benefit

In practice this means stable concentration control and less reagent and discharge waste, which cut the workload on the site maintenance team.

Food & Beverage

Food & Beverage · conductivity — Application Case

Project Background

The project covers dosing, pasteurising, filling and CIP stages. The work centres on conductivity and the core task is measuring conductivity to judge water purity or chemical concentration.

Operating Challenges

The medium and duty are characterised by syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. So conductivity cannot be specified generically — it calls for choosing two- or four-electrode cells by range and corrosivity.

Solution

The Ainstru engineering team worked through the analyser range: selecting as part of a complete water-analysis system. The configuration involves choosing two- or four-electrode cells by range and corrosivity, with these requirements in view: food-safety and hygienic design per 3-A / EHEDG.

Results

Since start-up the system has run steadily; the practical result is stable concentration control and less reagent and discharge waste.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · conductivity — Application Case

Project Overview

The site is reactors, metering vessels and finished-product tanks. The customer wanted conductivity properly configured on the existing plant, with the aim of measuring conductivity to judge water purity or chemical concentration.

Technical Challenges

What actually causes trouble is highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. All of this means the conductivity configuration has to involve choosing two- or four-electrode cells by range and corrosivity.

Configuration

Supply and installation were organised through the analyser range: selecting as part of a complete water-analysis system. On site this meant choosing two- or four-electrode cells by range and corrosivity, checked line by line against: Ex certification and GMP traceability of records.

Performance

After commissioning the outcome is stable concentration control and less reagent and discharge waste, and the readings are now used for process tuning.

Power & Energy

Power & Energy · conductivity — Application Case

Site Conditions

This is a Power & Energy customer whose plant is at boiler feedwater, turbine condensate and FGD/DeNOx systems. The main task was measuring conductivity to judge water purity or chemical concentration.

The Problem

The difficulty lies in high temperature and pressure with both steam and saline water; at the same time drift under high temperature and pressure, with very costly unplanned outages. Specification therefore means choosing two- or four-electrode cells by range and corrosivity.

What We Did

We took a analyser range approach — selecting as part of a complete water-analysis system. Delivery was built around choosing two- or four-electrode cells by range and corrosivity, with point-by-point checks on: compliance with power-industry codes and unit availability targets.

Operating Outcome

In service the system performs as intended — stable concentration control and less reagent and discharge waste, with routine maintenance falling noticeably.