Technical Data
CompareConductivity
| Measuring Principle | Conductive |
| Application | Process, power plant |
| Characteristic | 2-electrode conductivity cell for high temperature applications. |
| Measuring range | k=0,01: 0-20,0 µS/cm k=0,1: 0-200,0 µS/cm |
| Measuring principle | Coaxially arranged electrodes for high temperature applications |
| Design | 2-electrode conductivity cell with coaxially arranged electrodes Connection head and cooling body made of casting aluminium with fixed cable connection PG16 |
| Material | Electrode: 1.4571 Sealing: Kalrez, ceramic |
| Dimension | Electrode diameter: 25 mm (0.984 inch) Immersion depth: 50 to 115 mm (1.97 to 4.48 inch) Weight: 3kg |
| Process temperature | max. 250 °C (482 °F) |
| Process pressure | max. 40 bar (580 psi) |
| Temperature sensor | Integrated Pt100 |
| Ex certification | ATEX |
| Connection | Process connection: G1" |
| Ingress protection | IP67 |
| Certificates, declarations and approvals | Calibration certificate with cellconstant |
The Condumax CLS13 is a stable conductivity sensor for measuring in steam/water cycles in power plants, especially suitable for low-conductivity measurement applications (high temperature, high pressure), ensuring that the process is protected from corrosion. Low maintenance and easy commissioning (large terminal compartment) make it the ideal choice for harsh operating conditions.
Advantages
Reliable and precise measurement of low-conductivity media
Best choice for high-temperature, high-pressure applications (temperature up to 250 °C)
Stainless steel body and removable external electrode for easy cleaning
Robust and durable
Quality certificate includes independent cell constant specification
Areas of application
The Condumax CLS13 can be used for conductivity measurement in steam/water cycles in the power&energy industry:
Condensate monitoring
Boiler feedwater monitoring
Boiler blowdown control
The sensor can be used for low-conductivity media measurement under high temperature and high pressure.
Various international explosion protection approvals such as ATEX and FM, suitable for explosive hazardous areas
Spare Parts & Accessories 11
11 spare parts · click to collapse
| Order code | Description | |
|---|---|---|
| 50012511 | insulating sleeve | Details |
| 71603556 | CLS12/13 Outer Sheath | Details |
| 71603566 | CLS13 Seal Kit | Details |
| 50013937 | flat sealing gasketAlte Material-Nummer: 115731 | Details |
| 50089330 | electrode | Details |
| 50089331 | electrode | Details |
| 50081902 | Calibration solution 74.0 µS/cm500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISO | Details |
| 50081903 | calibration solution500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISO. | Details |
| 50081904 | Calibration solution 1.406 mS/cm500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISO | Details |
| 50081905 | calibration solution500 ml, reference temperature 25oC. Precision solution referred to SRM to NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISO | Details |
| 50081906 | calibration solution500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISO | Details |
Configurator / Comparison
A
Source:Endress+Hauserwebsite public information
Measuring principle video
Click to playManuals & Documents 6
All documents for this model6 documents · click to expand
Case Studies
Municipal Wastewater Treatment · conductivity — Application Case
Customer Profile
The typical setting in Municipal Wastewater Treatment is the inlet, biological and outlet stages of a municipal plant. The measuring point is conductivity; the focus is measuring conductivity to judge water purity or chemical concentration.
Key Difficulties
Conditions are high solids and corrosive fractions, with large diurnal flow swings and, on top of that, effluent parameters drift and probes foul with sludge and biofilm, which a standard configuration cannot handle for long. The design therefore starts with choosing two- or four-electrode cells by range and corrosivity.
Implementation
The scope ran through the analyser range: selecting as part of a complete water-analysis system. Technically it hinges on choosing two- or four-electrode cells by range and corrosivity, and on these requirements: stable compliance with Grade 1A discharge limits and online data reporting.
Customer Benefit
In practice this means stable concentration control and less reagent and discharge waste, which cut the workload on the site maintenance team.
Food & Beverage · conductivity — Application Case
Project Background
The project covers dosing, pasteurising, filling and CIP stages. The work centres on conductivity and the core task is measuring conductivity to judge water purity or chemical concentration.
Operating Challenges
The medium and duty are characterised by syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. So conductivity cannot be specified generically — it calls for choosing two- or four-electrode cells by range and corrosivity.
Solution
The Ainstru engineering team worked through the analyser range: selecting as part of a complete water-analysis system. The configuration involves choosing two- or four-electrode cells by range and corrosivity, with these requirements in view: food-safety and hygienic design per 3-A / EHEDG.
Results
Since start-up the system has run steadily; the practical result is stable concentration control and less reagent and discharge waste.
Chemical & Pharmaceutical · conductivity — Application Case
Project Overview
The site is reactors, metering vessels and finished-product tanks. The customer wanted conductivity properly configured on the existing plant, with the aim of measuring conductivity to judge water purity or chemical concentration.
Technical Challenges
What actually causes trouble is highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. All of this means the conductivity configuration has to involve choosing two- or four-electrode cells by range and corrosivity.
Configuration
Supply and installation were organised through the analyser range: selecting as part of a complete water-analysis system. On site this meant choosing two- or four-electrode cells by range and corrosivity, checked line by line against: Ex certification and GMP traceability of records.
Performance
After commissioning the outcome is stable concentration control and less reagent and discharge waste, and the readings are now used for process tuning.
Power & Energy · conductivity — Application Case
Site Conditions
This is a Power & Energy customer whose plant is at boiler feedwater, turbine condensate and FGD/DeNOx systems. The main task was measuring conductivity to judge water purity or chemical concentration.
The Problem
The difficulty lies in high temperature and pressure with both steam and saline water; at the same time drift under high temperature and pressure, with very costly unplanned outages. Specification therefore means choosing two- or four-electrode cells by range and corrosivity.
What We Did
We took a analyser range approach — selecting as part of a complete water-analysis system. Delivery was built around choosing two- or four-electrode cells by range and corrosivity, with point-by-point checks on: compliance with power-industry codes and unit availability targets.
Operating Outcome
In service the system performs as intended — stable concentration control and less reagent and discharge waste, with routine maintenance falling noticeably.