Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

CLS16 CondumaxDiscontinued

CLS16 Condumax
Condumax CLS16Discontinued
Configurable Models 7 models
Condumax CLS16 is a high-end conductivity sensor with certified hygienic design. It measures with highest precision providing you with reliable data for optimum process and product quality. Numerous certificates and various hygienic process connections ensure the perfect fit for your process.
Compare

Conductivity

Measuring Principle
Application Pharmaceuticals, pure and ultrapure water
Characteristic Hygienic 2-electrode conductivity sensor
Measuring range k=0,1: 0,04µS/cm - 500µS/cm
Measuring principle Conductive conductivity cell
Design Hygienic 2-electrode conductivity sensor with coaxially arranged electrodes, electropolished stainless steel and FDA sealing material; sterilizable
Material Isolation: PEEK
Electrode: polished stainless steel 1.4435
Sealing: Isolast (FFKM) FDA conform
Dimension Electrode diameter: 17 mm
(0.66 inch)
Electrode length: 54 mm
( 2.10 inch)
Process temperature Max. 120°C (150°C/30 min)
max. 248°F (302°F/30 min.)
Process pressure max. 12 bar at 20°C
max.174 psi at 68°F
Temperature sensor Integrated Pt100 or Pt1000
Ex certification ATEX
Connection Process connection: Varivent, Neumo, Clamp
Cable: TOP68 connector or fixed cable
Ingress protection IP68
Certificates, declarations and approvals - calibration certification - surface roughness Ra<0,8 (0,4)- Material certification 3.1.B - EHEDG, pharma certificate of compliance

Product Overview

Condumax CLS16D is a digital high-end conductivity sensor with hygienic design certification. It provides high-accuracy measurement and reliable data to optimize the measuring process and product quality. Numerous approvals and various hygienic process connections ensure a perfect fit for the measuring process.

  • Benefits

  • Highest measuring accuracy

  • Hygienic design, EHEDG certified

  • Wetted materials certified for biocompatibility in accordance with USP Cl. VI and FDA standards

  • Sterilizable and disinfectable

  • Quality certificate with cell constant specification

  • Application

  • Condumax CLS16 measures the conductivity of pure and ultrapure water for monitoring and controlling:

  • Ion exchangers

  • Reverse osmosis

  • Distillation

  • Electrodeionization

  • Water for injection (WFI)

  • With various international explosion protection approvals, such as ATEX, FM and CSA, the sensor is suitable for hazardous areas

Spare Parts & Accessories 2

2 spare parts · click to collapse
Order codeDescription
50081902Calibration solution 74.0 µS/cm500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISODetails
50081903calibration solution500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISO.Details

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products
7 models · click to collapse
All documents for this model
6 documents · click to expand
BA

Condumax CLS15/16/21 Chinese

Rev. 0622 28 pages
Preview
BA

Condumax CLS15/16/21 English

Rev. 0622 28 pages
Preview
TI

技术资料 Condumax CLS16, CLS16D Chinese

Rev. 1514 16 pages
Preview
TI

技术资料 Condumax CLS16, CLS16D Chinese

Rev. 1412 12 pages
Preview
TI

Technical Information Condumax CLS16/CLS16D English

Rev. 1514 16 pages
Preview
TI

Technical Information Condumax H CLS16 English

Rev. 1311 16 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · conductivity — Application Case

Customer Profile

The typical setting in Municipal Wastewater Treatment is the inlet, biological and outlet stages of a municipal plant. The measuring point is conductivity; the focus is measuring conductivity to judge water purity or chemical concentration.

Key Difficulties

Conditions are high solids and corrosive fractions, with large diurnal flow swings and, on top of that, effluent parameters drift and probes foul with sludge and biofilm, which a standard configuration cannot handle for long. The design therefore starts with choosing two- or four-electrode cells by range and corrosivity.

Implementation

The scope ran through the analyser range: selecting as part of a complete water-analysis system. Technically it hinges on choosing two- or four-electrode cells by range and corrosivity, and on these requirements: stable compliance with Grade 1A discharge limits and online data reporting.

Customer Benefit

In practice this means stable concentration control and less reagent and discharge waste, which cut the workload on the site maintenance team.

Food & Beverage

Food & Beverage · conductivity — Application Case

Project Background

The project covers dosing, pasteurising, filling and CIP stages. The work centres on conductivity and the core task is measuring conductivity to judge water purity or chemical concentration.

Operating Challenges

The medium and duty are characterised by syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. So conductivity cannot be specified generically — it calls for choosing two- or four-electrode cells by range and corrosivity.

Solution

The Ainstru engineering team worked through the analyser range: selecting as part of a complete water-analysis system. The configuration involves choosing two- or four-electrode cells by range and corrosivity, with these requirements in view: food-safety and hygienic design per 3-A / EHEDG.

Results

Since start-up the system has run steadily; the practical result is stable concentration control and less reagent and discharge waste.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · conductivity — Application Case

Project Overview

The site is reactors, metering vessels and finished-product tanks. The customer wanted conductivity properly configured on the existing plant, with the aim of measuring conductivity to judge water purity or chemical concentration.

Technical Challenges

What actually causes trouble is highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. All of this means the conductivity configuration has to involve choosing two- or four-electrode cells by range and corrosivity.

Configuration

Supply and installation were organised through the analyser range: selecting as part of a complete water-analysis system. On site this meant choosing two- or four-electrode cells by range and corrosivity, checked line by line against: Ex certification and GMP traceability of records.

Performance

After commissioning the outcome is stable concentration control and less reagent and discharge waste, and the readings are now used for process tuning.

Power & Energy

Power & Energy · conductivity — Application Case

Site Conditions

This is a Power & Energy customer whose plant is at boiler feedwater, turbine condensate and FGD/DeNOx systems. The main task was measuring conductivity to judge water purity or chemical concentration.

The Problem

The difficulty lies in high temperature and pressure with both steam and saline water; at the same time drift under high temperature and pressure, with very costly unplanned outages. Specification therefore means choosing two- or four-electrode cells by range and corrosivity.

What We Did

We took a analyser range approach — selecting as part of a complete water-analysis system. Delivery was built around choosing two- or four-electrode cells by range and corrosivity, with point-by-point checks on: compliance with power-industry codes and unit availability targets.

Operating Outcome

In service the system performs as intended — stable concentration control and less reagent and discharge waste, with routine maintenance falling noticeably.