Technical Data
CompareConductivity
| Measuring Principle | Conductive |
| Application | Pure and ultrapure water Pharmaceutical industry Final rinse WFI |
| Characteristic | Hygienic 2-electrode conductivity sensor |
| Measuring range | k=0,1: 0,04 to 500 µS/cm |
| Measuring principle | Conductive conductivity cell with electropolished stainless steel electrodes |
| Design | Hygienic 2-electrode conductivity sensor with coaxially arranged electrodes, electropolished |
| Material | n contact with medium Sensor depending on order execution: Electropolished, stainless steel 1.4435 (AISI 316L) PEEK Sealing depending on order execution: Form seal ISOLAST (FFKM) Form seal EPDM |
| Dimension | Electrode diameter: 17 mm (0.66 inch) Electrode length: 54 mm (2.13 inch) |
| Process temperature | -5 to 120 °C (23 to 248 °F) For Sterilizsation: max. 150 °C at 5 bar (Max. 302 °F at 73 psi) |
| Process pressure | 13 bar at 20 °C (188 psi at 68 °F) 9 bar at 120 °C (130 psi at 248 °F) |
| Temperature sensor | Pt1000 |
| Ex certification | ATEX, NEPSI, CSA, IECEx, INMETRO, EAC Ex |
| Connection | Process connection: Varivent, Neumo, BioControl, Clamp Sensor connection: Inductive, digital connection head with Memosens 2.0 technology |
| Ingress protection | IP68 |
| Certificates, declarations and approvals | Inspection certificate 3.1, EN10204 Surface roughness test ISO4287/Ra (≤ 0,38 µm) Conformity to cGMP derived requirements ASME BPE US Food Contact Materials FDA CFR 21 EU Food Contact Materials (EG) 1935/2004 CN Food Contact Materials GB 4806 EHEDG EL Class I |
The Memosens CLS16E is a high-end conductivity sensor with FDA and USP Cl. VI hygienic approvals. It reliably delivers high-precision measured values that help optimize processes and improve product quality. The sensor is robust, has replaceable seals and a long service life. The CLS16E uses Memosens 2.0 technology, stores calibration and process parameters in the sensor, and is the perfect basis for preventive maintenance and advancing IIoT technology.
Advantages
-
With quality certificate and EN 10204 3.1 material certificate, and approvals to EHEDG, USP Cl. VI, ASME and FDA, the Memosens CLS16E is the ideal choice for hygienic applications in the life sciences and food & beverage industries.
-
The sensor withstands high-temperature disinfection and autoclaving as well as CIP and SIP processes.
-
Stainless steel, robust and strongly corrosion-resistant, with replaceable seals and a long service life.
-
High-precision measurement even under high-temperature, pressurized conditions, reliably delivering measured values that help optimize processes and improve product quality.
-
Non-contact inductive signal transmission for high process integrity.
-
Supports IIoT: Memosens 2.0 supports extended data storage, saving calibration and process parameters for better trend identification, and is the perfect basis for preventive maintenance and advancing IIoT technology.
Application areas
-
The Memosens CLS16E measures conductivity in pure and ultrapure water applications for process monitoring:
-
Water for injection (WFI)
-
Ionization processes
-
Ion exchange columns
-
Reverse osmosis processes
-
Distillation
-
With international explosion protection approvals, e.g. ATEX, FM, CSA and NEPSI, the digital sensor can be used in hazardous areas.
Spare Parts & Accessories 2
2 spare parts · click to collapse
| Order code | Description | |
|---|---|---|
| 50081902 | Calibration solution 74.0 µS/cm500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISO | Details |
| 50081903 | calibration solution500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISO. | Details |
Configurator / Comparison
Accessories / Spare parts
Source:Endress+Hauserpublic information from the website
Manuals & Documents 4
All documents for this modelCase Studies
Municipal Wastewater Treatment · conductivity — Application Case
Customer Profile
The typical setting in Municipal Wastewater Treatment is the inlet, biological and outlet stages of a municipal plant. The measuring point is conductivity; the focus is measuring conductivity to judge water purity or chemical concentration.
Key Difficulties
Conditions are high solids and corrosive fractions, with large diurnal flow swings and, on top of that, effluent parameters drift and probes foul with sludge and biofilm, which a standard configuration cannot handle for long. The design therefore starts with choosing two- or four-electrode cells by range and corrosivity.
Implementation
The scope ran through the analyser range: selecting as part of a complete water-analysis system. Technically it hinges on choosing two- or four-electrode cells by range and corrosivity, and on these requirements: stable compliance with Grade 1A discharge limits and online data reporting.
Customer Benefit
In practice this means stable concentration control and less reagent and discharge waste, which cut the workload on the site maintenance team.
Food & Beverage · conductivity — Application Case
Project Background
The project covers dosing, pasteurising, filling and CIP stages. The work centres on conductivity and the core task is measuring conductivity to judge water purity or chemical concentration.
Operating Challenges
The medium and duty are characterised by syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. So conductivity cannot be specified generically — it calls for choosing two- or four-electrode cells by range and corrosivity.
Solution
The Ainstru engineering team worked through the analyser range: selecting as part of a complete water-analysis system. The configuration involves choosing two- or four-electrode cells by range and corrosivity, with these requirements in view: food-safety and hygienic design per 3-A / EHEDG.
Results
Since start-up the system has run steadily; the practical result is stable concentration control and less reagent and discharge waste.
Chemical & Pharmaceutical · conductivity — Application Case
Project Overview
The site is reactors, metering vessels and finished-product tanks. The customer wanted conductivity properly configured on the existing plant, with the aim of measuring conductivity to judge water purity or chemical concentration.
Technical Challenges
What actually causes trouble is highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. All of this means the conductivity configuration has to involve choosing two- or four-electrode cells by range and corrosivity.
Configuration
Supply and installation were organised through the analyser range: selecting as part of a complete water-analysis system. On site this meant choosing two- or four-electrode cells by range and corrosivity, checked line by line against: Ex certification and GMP traceability of records.
Performance
After commissioning the outcome is stable concentration control and less reagent and discharge waste, and the readings are now used for process tuning.
Power & Energy · conductivity — Application Case
Site Conditions
This is a Power & Energy customer whose plant is at boiler feedwater, turbine condensate and FGD/DeNOx systems. The main task was measuring conductivity to judge water purity or chemical concentration.
The Problem
The difficulty lies in high temperature and pressure with both steam and saline water; at the same time drift under high temperature and pressure, with very costly unplanned outages. Specification therefore means choosing two- or four-electrode cells by range and corrosivity.
What We Did
We took a analyser range approach — selecting as part of a complete water-analysis system. Delivery was built around choosing two- or four-electrode cells by range and corrosivity, with point-by-point checks on: compliance with power-industry codes and unit availability targets.
Operating Outcome
In service the system performs as intended — stable concentration control and less reagent and discharge waste, with routine maintenance falling noticeably.