Memosens CLS16E is a high-end conductivity sensor with certified hygienic design conforming to FDA and USP Class VI. It measures with highest precision delivering reliable data for optimum process and product quality. The sensor is robust and offers a long operating life thanks to its replaceable seal. With Memosens 2.0 technology, CLS16E is able to store more calibration and process data, facilitating predictive maintenance and providing the perfect basis for IIoT services.
Compare

Conductivity

Measuring Principle Conductive
Application Pure and ultrapure water
Pharmaceutical industry
Final rinse
WFI
Characteristic Hygienic 2-electrode conductivity sensor
Measuring range k=0,1: 0,04 to 500 µS/cm
Measuring principle Conductive conductivity cell with electropolished stainless steel electrodes
Design Hygienic 2-electrode conductivity sensor with coaxially arranged electrodes, electropolished
Material n contact with medium
Sensor depending on order execution:
Electropolished, stainless steel 1.4435 (AISI 316L)
PEEK
Sealing depending on order execution:
Form seal ISOLAST (FFKM)
Form seal EPDM
Dimension Electrode diameter: 17 mm (0.66 inch)
Electrode length: 54 mm (2.13 inch)
Process temperature -5 to 120 °C (23 to 248 °F)
For Sterilizsation: max. 150 °C at 5 bar
(Max. 302 °F at 73 psi)
Process pressure 13 bar at 20 °C (188 psi at 68 °F)
9 bar at 120 °C (130 psi at 248 °F)
Temperature sensor Pt1000
Ex certification ATEX, NEPSI, CSA, IECEx, INMETRO, EAC Ex
Connection Process connection: Varivent, Neumo, BioControl, Clamp
Sensor connection: Inductive, digital connection head with Memosens 2.0 technology
Ingress protection IP68
Certificates, declarations and approvals Inspection certificate 3.1, EN10204
Surface roughness test ISO4287/Ra (≤ 0,38 µm)
Conformity to cGMP derived requirements
ASME BPE
US Food Contact Materials FDA CFR 21
EU Food Contact Materials (EG) 1935/2004
CN Food Contact Materials GB 4806
EHEDG EL Class I

The Memosens CLS16E is a high-end conductivity sensor with FDA and USP Cl. VI hygienic approvals. It reliably delivers high-precision measured values that help optimize processes and improve product quality. The sensor is robust, has replaceable seals and a long service life. The CLS16E uses Memosens 2.0 technology, stores calibration and process parameters in the sensor, and is the perfect basis for preventive maintenance and advancing IIoT technology.

Advantages

  • With quality certificate and EN 10204 3.1 material certificate, and approvals to EHEDG, USP Cl. VI, ASME and FDA, the Memosens CLS16E is the ideal choice for hygienic applications in the life sciences and food & beverage industries.

  • The sensor withstands high-temperature disinfection and autoclaving as well as CIP and SIP processes.

  • Stainless steel, robust and strongly corrosion-resistant, with replaceable seals and a long service life.

  • High-precision measurement even under high-temperature, pressurized conditions, reliably delivering measured values that help optimize processes and improve product quality.

  • Non-contact inductive signal transmission for high process integrity.

  • Supports IIoT: Memosens 2.0 supports extended data storage, saving calibration and process parameters for better trend identification, and is the perfect basis for preventive maintenance and advancing IIoT technology.

Application areas

  • The Memosens CLS16E measures conductivity in pure and ultrapure water applications for process monitoring:

  • Water for injection (WFI)

  • Ionization processes

  • Ion exchange columns

  • Reverse osmosis processes

  • Distillation

  • With international explosion protection approvals, e.g. ATEX, FM, CSA and NEPSI, the digital sensor can be used in hazardous areas.

Spare Parts & Accessories 2

2 spare parts · click to collapse
Order codeDescription
50081902Calibration solution 74.0 µS/cm500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISODetails
50081903calibration solution500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISO.Details

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

Accessories / Spare parts

Source:Endress+Hauserpublic information from the website

3 models · click to collapse
All documents for this model
4 documents · click to expand
BA

BA Memosens CLS16E Chinese

Rev. 0424 20 pages
Preview
BA

BA Memosens CLS16E English

Rev. 0424 20 pages
Preview
TI

TI Memosens CLS16E Chinese

Rev. 0324 12 pages
Preview
TI

TI Memosens CLS16E English

Rev. 0324 12 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · conductivity — Application Case

Customer Profile

The typical setting in Municipal Wastewater Treatment is the inlet, biological and outlet stages of a municipal plant. The measuring point is conductivity; the focus is measuring conductivity to judge water purity or chemical concentration.

Key Difficulties

Conditions are high solids and corrosive fractions, with large diurnal flow swings and, on top of that, effluent parameters drift and probes foul with sludge and biofilm, which a standard configuration cannot handle for long. The design therefore starts with choosing two- or four-electrode cells by range and corrosivity.

Implementation

The scope ran through the analyser range: selecting as part of a complete water-analysis system. Technically it hinges on choosing two- or four-electrode cells by range and corrosivity, and on these requirements: stable compliance with Grade 1A discharge limits and online data reporting.

Customer Benefit

In practice this means stable concentration control and less reagent and discharge waste, which cut the workload on the site maintenance team.

Food & Beverage

Food & Beverage · conductivity — Application Case

Project Background

The project covers dosing, pasteurising, filling and CIP stages. The work centres on conductivity and the core task is measuring conductivity to judge water purity or chemical concentration.

Operating Challenges

The medium and duty are characterised by syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. So conductivity cannot be specified generically — it calls for choosing two- or four-electrode cells by range and corrosivity.

Solution

The Ainstru engineering team worked through the analyser range: selecting as part of a complete water-analysis system. The configuration involves choosing two- or four-electrode cells by range and corrosivity, with these requirements in view: food-safety and hygienic design per 3-A / EHEDG.

Results

Since start-up the system has run steadily; the practical result is stable concentration control and less reagent and discharge waste.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · conductivity — Application Case

Project Overview

The site is reactors, metering vessels and finished-product tanks. The customer wanted conductivity properly configured on the existing plant, with the aim of measuring conductivity to judge water purity or chemical concentration.

Technical Challenges

What actually causes trouble is highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. All of this means the conductivity configuration has to involve choosing two- or four-electrode cells by range and corrosivity.

Configuration

Supply and installation were organised through the analyser range: selecting as part of a complete water-analysis system. On site this meant choosing two- or four-electrode cells by range and corrosivity, checked line by line against: Ex certification and GMP traceability of records.

Performance

After commissioning the outcome is stable concentration control and less reagent and discharge waste, and the readings are now used for process tuning.

Power & Energy

Power & Energy · conductivity — Application Case

Site Conditions

This is a Power & Energy customer whose plant is at boiler feedwater, turbine condensate and FGD/DeNOx systems. The main task was measuring conductivity to judge water purity or chemical concentration.

The Problem

The difficulty lies in high temperature and pressure with both steam and saline water; at the same time drift under high temperature and pressure, with very costly unplanned outages. Specification therefore means choosing two- or four-electrode cells by range and corrosivity.

What We Did

We took a analyser range approach — selecting as part of a complete water-analysis system. Delivery was built around choosing two- or four-electrode cells by range and corrosivity, with point-by-point checks on: compliance with power-industry codes and unit availability targets.

Operating Outcome

In service the system performs as intended — stable concentration control and less reagent and discharge waste, with routine maintenance falling noticeably.