Condumax CLS21D is a robust conductivity sensor for all process and environmental applications. It provides you with precise and reliable measuring values for an optimum process and product quality monitoring. Better still, the sensor features high chemical, thermal and mechanical stability and high durability. Condumax CLS21D is not the latest Memosens generation. To get information on the new Memosens CLS21E sensor with extended functionality, click here.
Compare

Conductivity

Measuring Principle
Application Water, waste water, process, media separation, industrial water
Characteristic 2-electrode system for application in the middle application range
Measuring range k=1: 10 µS/cm to 20 mS/cm
Measuring principle Conductive conductivity cell with graphite electrodes for applications in the middle range
Design 2-electrode system with parallel arranged electrodes
Material Sensor shaft: PES
Electrodes: graphite
Dimension Diameter: 24 mm (0.94 inch)
Length: 61 mm (2.40 inch)
Process temperature -20 to 135 °C at 3.5 bar abs
(-4 to 275 °F at 50 psi)
Process pressure 17 bar abs at 20 °C
(246 psi at 68 °F)
Temperature sensor NTC 30K
Ex certification ATEX, NEPSI, EAC
Connection Process connection: DN25, DN40, G1, NPT 1"
Cable: Memosens connector CYK10
Ingress protection IP68 (connector)

For the same analog range, use CLS21; for low-range analog measurement of pure water, use CLS19; for digital, use CLS15D.

Condumax CLS21D is a robust conductivity sensor suitable for all process and environmental industries. It provides accurate and reliable measured values to optimize process and product quality monitoring. Even better, the sensor has extremely high chemical, thermal and mechanical stability and is robust. Based on Memosens digital technology, CLS21D achieves maximum process and data integrity through simple operation, is corrosion-resistant, moisture-proof and enables predictive maintenance.

 

Benefits

Reliable and accurate measurement in medium/high conductivity applications

Robust with low maintenance requirements

High chemical, thermal and mechanical stability

Quality certificate with independent cell constant specification

Sensor-specific parameters are recorded for traceability and predictive maintenance

Maximum process safety through non-contact inductive signal transmission

 

Application

Condumax CLS21D is used for conductivity measurement in the process and environmental industries, such as:

 

Drinking water treatment

Desalination plants

Industrial water treatment

River/lake water monitoring

Phase separation in medium conductivity applications (e.g. milk/water)

With various international explosion protection approvals, such as ATEX, FM, CSA and NEPSI, this digital sensor is suitable for hazardous areas

Spare Parts & Accessories 5

5 spare parts · click to collapse
Order codeDescription
50081902Calibration solution 74.0 µS/cm500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISODetails
50081903calibration solution500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISO.Details
50081904Calibration solution 1.406 mS/cm500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISODetails
50081905calibration solution500 ml, reference temperature 25oC. Precision solution referred to SRM to NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISODetails
50081906calibration solution500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISODetails

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

A

   

Measuring Principle Video

Click to play

Source:Endress+Hauserwebsite public information

3 models · click to collapse
All documents for this model
7 documents · click to expand
BA

Condumax CLS15D, CLS16D, CLS21D Chinese

Rev. 0722 28 pages
Preview
BA

Condumax CLS15D/16D/21D English

Rev. 0722 28 pages
Preview
TI

技术资料 Condumax CLS21, CLS21D Chinese

Rev. 1414 16 pages
Preview
TI

技术资料 Condumax CLS21, CLS21D Chinese

Rev. 1312 16 pages
Preview
TI

技术资料 Condumax CLS21/CLS21D Chinese

Rev. 0410 16 pages
Preview
TI

Condumax CLS21D/CLS21 Technical Information English

Rev. 1518 16 pages
Preview
TI

Technical Information CLS21 and CLS21D English

16 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · conductivity — Application Case

Customer Profile

The typical setting in Municipal Wastewater Treatment is the inlet, biological and outlet stages of a municipal plant. The measuring point is conductivity; the focus is measuring conductivity to judge water purity or chemical concentration.

Key Difficulties

Conditions are high solids and corrosive fractions, with large diurnal flow swings and, on top of that, effluent parameters drift and probes foul with sludge and biofilm, which a standard configuration cannot handle for long. The design therefore starts with choosing two- or four-electrode cells by range and corrosivity.

Implementation

The scope ran through the analyser range: selecting as part of a complete water-analysis system. Technically it hinges on choosing two- or four-electrode cells by range and corrosivity, and on these requirements: stable compliance with Grade 1A discharge limits and online data reporting.

Customer Benefit

In practice this means stable concentration control and less reagent and discharge waste, which cut the workload on the site maintenance team.

Food & Beverage

Food & Beverage · conductivity — Application Case

Project Background

The project covers dosing, pasteurising, filling and CIP stages. The work centres on conductivity and the core task is measuring conductivity to judge water purity or chemical concentration.

Operating Challenges

The medium and duty are characterised by syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. So conductivity cannot be specified generically — it calls for choosing two- or four-electrode cells by range and corrosivity.

Solution

The Ainstru engineering team worked through the analyser range: selecting as part of a complete water-analysis system. The configuration involves choosing two- or four-electrode cells by range and corrosivity, with these requirements in view: food-safety and hygienic design per 3-A / EHEDG.

Results

Since start-up the system has run steadily; the practical result is stable concentration control and less reagent and discharge waste.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · conductivity — Application Case

Project Overview

The site is reactors, metering vessels and finished-product tanks. The customer wanted conductivity properly configured on the existing plant, with the aim of measuring conductivity to judge water purity or chemical concentration.

Technical Challenges

What actually causes trouble is highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. All of this means the conductivity configuration has to involve choosing two- or four-electrode cells by range and corrosivity.

Configuration

Supply and installation were organised through the analyser range: selecting as part of a complete water-analysis system. On site this meant choosing two- or four-electrode cells by range and corrosivity, checked line by line against: Ex certification and GMP traceability of records.

Performance

After commissioning the outcome is stable concentration control and less reagent and discharge waste, and the readings are now used for process tuning.

Power & Energy

Power & Energy · conductivity — Application Case

Site Conditions

This is a Power & Energy customer whose plant is at boiler feedwater, turbine condensate and FGD/DeNOx systems. The main task was measuring conductivity to judge water purity or chemical concentration.

The Problem

The difficulty lies in high temperature and pressure with both steam and saline water; at the same time drift under high temperature and pressure, with very costly unplanned outages. Specification therefore means choosing two- or four-electrode cells by range and corrosivity.

What We Did

We took a analyser range approach — selecting as part of a complete water-analysis system. Delivery was built around choosing two- or four-electrode cells by range and corrosivity, with point-by-point checks on: compliance with power-industry codes and unit availability targets.

Operating Outcome

In service the system performs as intended — stable concentration control and less reagent and discharge waste, with routine maintenance falling noticeably.