Order Code:CLS50D-9PC1/0
Corresponding ext. order code:CLS50D-NA1D21
Name:Indumax CLS50D
Configuration
| Code | Name | Order | Specification |
|---|---|---|---|
| 010 | Approval | NA | NEPSI Ex ia IIC T4/T6 Ga |
| 020 | Process Connection | 1 | Thread G3/4; |
| 030 | Sensor-, Seal-; Adapter Material | D | PFA; Chemraz; 1.4571 |
| 040 | Cable length | 2 | 7 m |
| 050 | Cable Connection | 1 | Fixed cable; crimp sleeves |
Configuration Explained
This is a CLS50D toroidal conductivity sensor with Memosens digital technology, for the chemical industry, with NEPSI intrinsically safe approval for entry into hazardous areas, process connection G3/4 thread, adapter PFA, seal Chemraz, electrode 1.4571, the perfluorinated connection withstands strong acids and alkalis, 7 m fixed cable with terminals, digital signal without attenuation, suitable for acid and alkaline media and hazardous area piping measurement.