Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

CLS54 Indumax

CLS54 Indumax
Indumax CLS54
Configurable Models 20 models
The Indumax CLS54 inductive conductivity sensor protects all of your products and processes that must meet the strictest hygienic and sterile demands. Its outstanding performance combined with a unique hygienic design ensures highest safety and quality of your products.
Compare

Conductivity

Measuring Principle Inductive
Application Food, beverage and pharmaceutical industries and in biotechnology.
Characteristic Specifically intended for use in hygienic applications and especially suitable for following applications:
Phase separation, control of CIP, concentration control, product monitoring, leakage monitoring.
Measuring range 100 µS/cm - 2000 mS/cm Cell constant k: 6,3 1/cm
Measuring principle Inductive conductivity measurement
Design Hygienic design with food-grade virgin PEEK body in jointless and creviceless design including all hygienic certifications.
Material In contact with medium: Virgin PEEK
Surface roughness: Ra<0.9µm
Process temperature Process temperature: -10°C - +125°C
(14°F - 257°F)
Sterilisation: 150°C/5 bar (max. 60 min.)
(302°F / 72.5 psi)
Process pressure 12 bar(174 psi)/20°C(68°F)
8 bar(116 psi)/125°C(257°F)
Temperature sensor Pt1000 (class A)with a temperature response time T90 < 27s.
Ex certification ATEX II G EEx ia IIc T3/T4/T6
FM/CSA IS NI CL.I,II,III,Div.1&2 group A-G in connection with the transmitter CM42.
Connection Dairy pipe, Aseptic-fitting, Clamp ISO 2852, SMS-2", Varivent N DN 40-125, Neumo Biocontrol D50.
Ingress protection IP68/NEMA6P
Certificates, declarations and approvals Surface roughness test ISO4287/Ra (≤ 0,8 µm)
Bio reactivity test USP Class VI
US Food Contact Materials FDA CFR 21
EU Food Contact Materials (EG) 1935/2004
CN Food Contact Materials GB 4806
EHEDG EL Class I, 3-A

The Indumax CLS54 inductive conductivity sensor ensures that all products and processes meet the strictest hygiene and sterility requirements. It combines high performance with a unique hygienic design to ensure product quality and maximum safety.

 

Advantages

Unique hygienic design prevents contamination

All hygienic approvals for hygienic applications

Food-grade PEEK body with seamless, joint-free connection

Biocompatibility approval compliant with USP Cl.VI

Suitable for CIP and SIP

Compliant with EG 2023/2006 and 1935/2004

 

Areas of application

The Indumax CLS54 can be used for toroidal conductivity measurement in the food&beverage industry and the life sciences sector, e.g.:

 

Phase separation between medium/water and medium/medium mixtures in pipes

CIP process control in return lines

Concentration control during CIP cleaning agent preparation

Medium monitoring in pipes, bottling plants and quality assurance systems

Leak monitoring

Unique hygienic design with EHEDG and 3-A approval

Spare Parts & Accessories 6

6 spare parts · click to collapse
Order codeDescription
71183688Extension cableDetails
50081902Calibration solution 74.0 µS/cm500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISODetails
50081903calibration solution500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISO.Details
50081904Calibration solution 1.406 mS/cm500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISODetails
50081905calibration solution500 ml, reference temperature 25oC. Precision solution referred to SRM to NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISODetails
50081906calibration solution500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISODetails

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

A

   

Measuring principle video

Click to play
185 models · click to collapse
All documents for this model
6 documents · click to expand
BA

BA Indumax CLS54 Chinese

Rev. 0726 24 pages
Preview
BA

BA Indumax CLS54 English

Rev. 0726 24 pages
Preview
TI

技术资料 Indumax CLS54 Chinese

Rev. 1316 16 pages
Preview
TI

技术资料 Indumax H CLS54 Chinese

Rev. 0710 12 pages
Preview
TI

Indumax CLS54 Technical Information English

Rev. 1316 16 pages
Preview
TI

Technical Information Indumax H CLS54 English

Rev. 0710 12 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · conductivity — Application Case

Customer Profile

The typical setting in Municipal Wastewater Treatment is the inlet, biological and outlet stages of a municipal plant. The measuring point is conductivity; the focus is measuring conductivity to judge water purity or chemical concentration.

Key Difficulties

Conditions are high solids and corrosive fractions, with large diurnal flow swings and, on top of that, effluent parameters drift and probes foul with sludge and biofilm, which a standard configuration cannot handle for long. The design therefore starts with choosing two- or four-electrode cells by range and corrosivity.

Implementation

The scope ran through the analyser range: selecting as part of a complete water-analysis system. Technically it hinges on choosing two- or four-electrode cells by range and corrosivity, and on these requirements: stable compliance with Grade 1A discharge limits and online data reporting.

Customer Benefit

In practice this means stable concentration control and less reagent and discharge waste, which cut the workload on the site maintenance team.

Food & Beverage

Food & Beverage · conductivity — Application Case

Project Background

The project covers dosing, pasteurising, filling and CIP stages. The work centres on conductivity and the core task is measuring conductivity to judge water purity or chemical concentration.

Operating Challenges

The medium and duty are characterised by syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. So conductivity cannot be specified generically — it calls for choosing two- or four-electrode cells by range and corrosivity.

Solution

The Ainstru engineering team worked through the analyser range: selecting as part of a complete water-analysis system. The configuration involves choosing two- or four-electrode cells by range and corrosivity, with these requirements in view: food-safety and hygienic design per 3-A / EHEDG.

Results

Since start-up the system has run steadily; the practical result is stable concentration control and less reagent and discharge waste.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · conductivity — Application Case

Project Overview

The site is reactors, metering vessels and finished-product tanks. The customer wanted conductivity properly configured on the existing plant, with the aim of measuring conductivity to judge water purity or chemical concentration.

Technical Challenges

What actually causes trouble is highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. All of this means the conductivity configuration has to involve choosing two- or four-electrode cells by range and corrosivity.

Configuration

Supply and installation were organised through the analyser range: selecting as part of a complete water-analysis system. On site this meant choosing two- or four-electrode cells by range and corrosivity, checked line by line against: Ex certification and GMP traceability of records.

Performance

After commissioning the outcome is stable concentration control and less reagent and discharge waste, and the readings are now used for process tuning.

Power & Energy

Power & Energy · conductivity — Application Case

Site Conditions

This is a Power & Energy customer whose plant is at boiler feedwater, turbine condensate and FGD/DeNOx systems. The main task was measuring conductivity to judge water purity or chemical concentration.

The Problem

The difficulty lies in high temperature and pressure with both steam and saline water; at the same time drift under high temperature and pressure, with very costly unplanned outages. Specification therefore means choosing two- or four-electrode cells by range and corrosivity.

What We Did

We took a analyser range approach — selecting as part of a complete water-analysis system. Delivery was built around choosing two- or four-electrode cells by range and corrosivity, with point-by-point checks on: compliance with power-industry codes and unit availability targets.

Operating Outcome

In service the system performs as intended — stable concentration control and less reagent and discharge waste, with routine maintenance falling noticeably.