Instrumentation · Engineering · Package · PLC
0755-8222 1901 sales@ainstru.com

CLS54D 电导率传感器

CLS54D 电导率传感器

Indumax CLS54D

The Indumax CLS54D inductive conductivity sensor protects all of your products and processes that must meet the strictest hygienic and sterile demands. Its outstanding performance combined with a unique hygienic design ensures highest safety and quality of your products. Thanks to Memosens digital technology, Indumax CLS54D combines maximum process and data integrity with simple operation. It resists corrosion and moisture, enables lab calibration, and facilitates predictive maintenance.
Compare

Conductivity

Measuring Principle Inductive
Application Food, beverage and pharmaceutical industries, biotechnology, dairies, breweries
Characteristic Specifically intended for use in hygienic applications and especially suitable for following applications:
Phase separation, control of CIP, concentration control, product monitoring, leakage monitoring
Measuring range 100 µS/cm to 2000 mS/cm
Cell constant k: 6.3 1/cm
Measuring principle Inductive conductivity measurement
Design Hygienic design with food-grade virgin PEEK body in jointless and creviceless design including all hygienic certifications
Material In contact with medium: virgin PEEK
Process temperature -10 °C to 125 °C (14 °F to 257 °F)
Sterilization: 150 °C at 6 bar abs for max. 60 min
(302 °F at 87 psi abs for max. 60 min)
Process pressure 13 bar abs up to 90 °C (188.5 psi abs up to 194 °F)
9 bar at 125 °C (130.5 psi abs at 257 °F)
Temperature sensor Pt1000 (Class A according to IEC 60751)
Connection Dairy pipe, Aseptic-fitting, Clamp ISO 2852, SMS-2", Varivent N DN 40-125, Neumo Biocontrol D50
Ingress protection IP68 / NEMA type 6P
Certificates, declarations and approvals Surface roughness test ISO4287/Ra (≤ 0,8 µm)
Bio reactivity test USP Class VI
US Food Contact Materials FDA CFR 21
EU Food Contact Materials (EG) 1935/2004
CN Food Contact Materials GB 4806
EHEDG EL Class I, 3-A

The Indumax CLS54D inductive conductivity sensor ensures that all products and processes meet the strictest hygiene and sterility requirements. It combines high performance with a unique hygienic design to guarantee the highest product quality and maximum safety. Based on Memosens digital technology, the Indumax CLS54D combines simple operation with maximum process and data integration; it is corrosion- and moisture-resistant, can be laboratory-calibrated and facilitates predictive maintenance.

 

Advantages

Unique hygienic design prevents contamination

All approvals for hygienic and sterile applications, compliant with EG 2023/2006 and 1935/2004

Food-grade PEEK body with seamless, joint-free connection

Biocompatibility approval compliant with USP Cl. VI

Suitable for CIP and SIP

Convenient maintenance strategy with data and sensor management via Memobase Plus

Reliable measurement based on connection monitoring and EMC protection

 

Areas of application

The Indumax CLS54D can be used for toroidal conductivity measurement in the food and beverage and life sciences sectors, e.g.:

 

Phase separation between medium/medium and medium/water in piping systems

CIP process control in return channels

Concentration control during CIP cleaning agent regeneration

Medium monitoring in piping systems, filling plants and quality assurance systems

Leak monitoring

Unique hygienic design compliant with EHEDG and 3-A

 

 

 

E+H Product Configurator

Please enter the product order code to configure

Product comparison

Please enter the order codes of the products to compare in the boxes below (up to three products)

 

   

Technical documentation

   

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

A

Source:Endress+Hauserwebsite public information

Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · Conductivity Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Conductivity.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Conductivity for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · Conductivity Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Conductivity.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Conductivity for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · Conductivity Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Conductivity.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Conductivity for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · Conductivity Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Conductivity.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Conductivity for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.