Technical Data
CompareConductivity
| Measuring Principle | Inductive |
| Application | Food, beverage and pharmaceutical industries, biotechnology, dairies, breweries |
| Characteristic | Specifically intended for use in hygienic applications and especially suitable for following applications: Phase separation, control of CIP, concentration control, product monitoring, leakage monitoring |
| Measuring range | 100 µS/cm to 2000 mS/cm Cell constant k: 6.3 1/cm |
| Measuring principle | Inductive conductivity measurement |
| Design | Hygienic design with food-grade virgin PEEK body in jointless and creviceless design including all hygienic certifications |
| Material | In contact with medium: virgin PEEK |
| Process temperature | -10 °C to 125 °C (14 °F to 257 °F) Sterilization: 150 °C at 6 bar abs for max. 60 min (302 °F at 87 psi abs for max. 60 min) |
| Process pressure | 13 bar abs up to 90 °C (188.5 psi abs up to 194 °F) 9 bar at 125 °C (130.5 psi abs at 257 °F) |
| Temperature sensor | Pt1000 (Class A according to IEC 60751) |
| Connection | Dairy pipe, Aseptic-fitting, Clamp ISO 2852, SMS-2", Varivent N DN 40-125, Neumo Biocontrol D50 |
| Ingress protection | IP68 / NEMA type 6P |
| Certificates, declarations and approvals | Surface roughness test ISO4287/Ra (≤ 0,8 µm) Bio reactivity test USP Class VI US Food Contact Materials FDA CFR 21 EU Food Contact Materials (EG) 1935/2004 CN Food Contact Materials GB 4806 EHEDG EL Class I, 3-A |
The Indumax CLS54D inductive conductivity sensor ensures that all products and processes meet the strictest hygiene and sterility requirements. It combines high performance with a unique hygienic design to guarantee the highest product quality and maximum safety. Based on Memosens digital technology, the Indumax CLS54D combines simple operation with maximum process and data integration; it is corrosion- and moisture-resistant, can be laboratory-calibrated and facilitates predictive maintenance.
Advantages
Unique hygienic design prevents contamination
All approvals for hygienic and sterile applications, compliant with EG 2023/2006 and 1935/2004
Food-grade PEEK body with seamless, joint-free connection
Biocompatibility approval compliant with USP Cl. VI
Suitable for CIP and SIP
Convenient maintenance strategy with data and sensor management via Memobase Plus
Reliable measurement based on connection monitoring and EMC protection
Areas of application
The Indumax CLS54D can be used for toroidal conductivity measurement in the food and beverage and life sciences sectors, e.g.:
Phase separation between medium/medium and medium/water in piping systems
CIP process control in return channels
Concentration control during CIP cleaning agent regeneration
Medium monitoring in piping systems, filling plants and quality assurance systems
Leak monitoring
Unique hygienic design compliant with EHEDG and 3-A
Spare Parts & Accessories 5
5 spare parts · click to collapse
| Order code | Description | |
|---|---|---|
| 50081902 | Calibration solution 74.0 µS/cm500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISO | Details |
| 50081903 | calibration solution500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISO. | Details |
| 50081904 | Calibration solution 1.406 mS/cm500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISO | Details |
| 50081905 | calibration solution500 ml, reference temperature 25oC. Precision solution referred to SRM to NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISO | Details |
| 50081906 | calibration solution500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISO | Details |
Configurator / Comparison
A
Source:Endress+Hauserwebsite public information
Measuring principle video
Click to playManuals & Documents 6
All documents for this modelCase Studies
Municipal Wastewater Treatment · conductivity — Application Case
Customer Profile
The typical setting in Municipal Wastewater Treatment is the inlet, biological and outlet stages of a municipal plant. The measuring point is conductivity; the focus is measuring conductivity to judge water purity or chemical concentration.
Key Difficulties
Conditions are high solids and corrosive fractions, with large diurnal flow swings and, on top of that, effluent parameters drift and probes foul with sludge and biofilm, which a standard configuration cannot handle for long. The design therefore starts with choosing two- or four-electrode cells by range and corrosivity.
Implementation
The scope ran through the analyser range: selecting as part of a complete water-analysis system. Technically it hinges on choosing two- or four-electrode cells by range and corrosivity, and on these requirements: stable compliance with Grade 1A discharge limits and online data reporting.
Customer Benefit
In practice this means stable concentration control and less reagent and discharge waste, which cut the workload on the site maintenance team.
Food & Beverage · conductivity — Application Case
Project Background
The project covers dosing, pasteurising, filling and CIP stages. The work centres on conductivity and the core task is measuring conductivity to judge water purity or chemical concentration.
Operating Challenges
The medium and duty are characterised by syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. So conductivity cannot be specified generically — it calls for choosing two- or four-electrode cells by range and corrosivity.
Solution
The Ainstru engineering team worked through the analyser range: selecting as part of a complete water-analysis system. The configuration involves choosing two- or four-electrode cells by range and corrosivity, with these requirements in view: food-safety and hygienic design per 3-A / EHEDG.
Results
Since start-up the system has run steadily; the practical result is stable concentration control and less reagent and discharge waste.
Chemical & Pharmaceutical · conductivity — Application Case
Project Overview
The site is reactors, metering vessels and finished-product tanks. The customer wanted conductivity properly configured on the existing plant, with the aim of measuring conductivity to judge water purity or chemical concentration.
Technical Challenges
What actually causes trouble is highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. All of this means the conductivity configuration has to involve choosing two- or four-electrode cells by range and corrosivity.
Configuration
Supply and installation were organised through the analyser range: selecting as part of a complete water-analysis system. On site this meant choosing two- or four-electrode cells by range and corrosivity, checked line by line against: Ex certification and GMP traceability of records.
Performance
After commissioning the outcome is stable concentration control and less reagent and discharge waste, and the readings are now used for process tuning.
Power & Energy · conductivity — Application Case
Site Conditions
This is a Power & Energy customer whose plant is at boiler feedwater, turbine condensate and FGD/DeNOx systems. The main task was measuring conductivity to judge water purity or chemical concentration.
The Problem
The difficulty lies in high temperature and pressure with both steam and saline water; at the same time drift under high temperature and pressure, with very costly unplanned outages. Specification therefore means choosing two- or four-electrode cells by range and corrosivity.
What We Did
We took a analyser range approach — selecting as part of a complete water-analysis system. Delivery was built around choosing two- or four-electrode cells by range and corrosivity, with point-by-point checks on: compliance with power-industry codes and unit availability targets.
Operating Outcome
In service the system performs as intended — stable concentration control and less reagent and discharge waste, with routine maintenance falling noticeably.