Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

COA30 Flowfit

COA30 Flowfit
Flowfit COA30
The Flowfit COA30 flow cell quickly calibrates oxygen sensors with test gases. This portable calibration tool ensures reliable measurements and smooth processes.
Compare

Oxygen

Measuring Principle Amperometric oxygen measurement
Application Calibration of oxygen sensors with defined test gases
Installation for 12 mm sensors with standard process connection Pg13.5
for lengths from 120 mm to 420 mm
Material POM (flow cell)
Stainless steel (hose connections)
TPE (edge protection)
TSE/BSE compliant
Dimension Diameter of flow cell: 56 mm
Height of flow cell (without stand base): 195 mm
Height of stand base: 54 mm
Diameter of stand base: 98 mm
Process temperature 0 to 50 °C (32 to 122 °F)
Process pressure 1 to 10 bar (abs) (14.5 to 145 psi)
Connection 4 mm OD hose connection

COA30 flow assembly for calibrating dissolved oxygen sensors with a length of 120...360 mm and a diameter of 12 mm

Advantages
• Precise calibration of dissolved oxygen sensors using test gas: the COA30 calibration vessel enables precise calibration of dissolved oxygen sensors to match the requirements of the relevant measuring point exactly.
• Easy calibration of dissolved oxygen sensors: install the sensor in the calibration vessel, connect the corresponding transmitter and supply a suitable test gas to complete the calibration easily.
• Saves time on zero-point calibration: calibration with the COA30 calibration vessel is significantly faster than conventional calibration methods using sodium sulfite or zero-point gel.
• After calibration with the COA30, no residue remains on the sensor, so cleaning is not required. Calibration with a test gas (e.g. nitrogen) eliminates subsequent cleaning work.
• Compatible with sensors of various sizes: the calibration vessel is suitable for 12 mm dissolved oxygen sensors with PG13.5 thread connection and lengths from 120 mm...360 mm, offering a wide range of applications.

Field of application

The Flowfit COA30 is an efficient tool for calibrating oxygen sensors. The sensor can be installed quickly and easily in the flow assembly and calibrated with a test gas —— precisely tailored to your specific measuring requirements. The Flowfit COA30 is lightweight and portable, and can be used immediately anywhere. By using it to calibrate oxygen sensors, you can increase the reliability of the measuring point and ensure that the process runs smoothly. The Flowfit COA30 is used in various industries and applications where precise and efficient calibration of oxygen sensors is required, for example:

Power and energy:
- water and steam cycles

Life sciences:
- fermentation processes

Food and beverage:
- preparation
- filling
- storage

Chemical:
- inertization

Spare Parts & Accessories 7

7 spare parts · click to collapse
Order codeDescription
71685364Kit COA30 needle valveDetails
71685366Kit COA30-*CA* 2x Hose ConnectionPMMA versionDetails
71685378Kit COA30-*CB* 2x Hose ConnectionPOM versionDetails
71685381Kit COA30 2x edge protectionDetails
71685382Kit COA30 blind plugDetails
71685384COA30 sealing set kitDetails
71707975COA30 adapter kit for sensor >120 mmDetails

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

Source:Endress+Hauserpublic information from the website

All documents for this model
8 documents · click to expand
BA

BA Flowfit COA30 Chinese

Rev. 0226 24 pages
Preview
BA

BA Flowfit COA30 Chinese

Rev. 0125 20 pages
Preview
BA

BA Flowfit COA30 English

Rev. 0226 24 pages
Preview
BA

BA Flowfit COA30 English

Rev. 0125 20 pages
Preview
TI

TI Flowfit COA30 Chinese

Rev. 0125 8 pages
Preview
TI

TI Flowfit COA30 Chinese

Rev. 0125 8 pages
Preview
TI

TI Flowfit COA30 English

Rev. 0125 8 pages
Preview
TI

TI Flowfit COA30 English

Rev. 0125 8 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · brackets — Application Case

Customer Profile

The typical setting in Municipal Wastewater Treatment is the inlet, biological and outlet stages of a municipal plant. The measuring point is brackets; the focus is mounting, fixation and position adjustment for instruments.

Key Difficulties

Conditions are high solids and corrosive fractions, with large diurnal flow swings and, on top of that, effluent parameters drift and probes foul with sludge and biofilm, which a standard configuration cannot handle for long. The design therefore starts with checking structural strength by material, corrosion class and load.

Implementation

The scope ran through the system components range: supplying as a full cabinet and signal-chain configuration. Technically it hinges on checking structural strength by material, corrosion class and load, and on these requirements: stable compliance with Grade 1A discharge limits and online data reporting.

Customer Benefit

In practice this means accurate mounting positions that remove measurement bias at the source, which cut the workload on the site maintenance team.

Food & Beverage

Food & Beverage · brackets — Application Case

Project Background

The project covers dosing, pasteurising, filling and CIP stages. The work centres on brackets and the core task is mounting, fixation and position adjustment for instruments.

Operating Challenges

The medium and duty are characterised by syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. So brackets cannot be specified generically — it calls for checking structural strength by material, corrosion class and load.

Solution

The Ainstru engineering team worked through the system components range: supplying as a full cabinet and signal-chain configuration. The configuration involves checking structural strength by material, corrosion class and load, with these requirements in view: food-safety and hygienic design per 3-A / EHEDG.

Results

Since start-up the system has run steadily; the practical result is accurate mounting positions that remove measurement bias at the source.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · brackets — Application Case

Project Overview

The site is reactors, metering vessels and finished-product tanks. The customer wanted brackets properly configured on the existing plant, with the aim of mounting, fixation and position adjustment for instruments.

Technical Challenges

What actually causes trouble is highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. All of this means the brackets configuration has to involve checking structural strength by material, corrosion class and load.

Configuration

Supply and installation were organised through the system components range: supplying as a full cabinet and signal-chain configuration. On site this meant checking structural strength by material, corrosion class and load, checked line by line against: Ex certification and GMP traceability of records.

Performance

After commissioning the outcome is accurate mounting positions that remove measurement bias at the source, and the readings are now used for process tuning.

Power & Energy

Power & Energy · brackets — Application Case

Site Conditions

This is a Power & Energy customer whose plant is at boiler feedwater, turbine condensate and FGD/DeNOx systems. The main task was mounting, fixation and position adjustment for instruments.

The Problem

The difficulty lies in high temperature and pressure with both steam and saline water; at the same time drift under high temperature and pressure, with very costly unplanned outages. Specification therefore means checking structural strength by material, corrosion class and load.

What We Did

We took a system components range approach — supplying as a full cabinet and signal-chain configuration. Delivery was built around checking structural strength by material, corrosion class and load, with point-by-point checks on: compliance with power-industry codes and unit availability targets.

Operating Outcome

In service the system performs as intended — accurate mounting positions that remove measurement bias at the source, with routine maintenance falling noticeably.