Instrumentation · Engineering · Package · PLC
0755-8222 1901 sales@ainstru.com

FMD78 differential pressure transmitter

FMD78 differential pressure transmitter

Deltabar S FMD78

Configurable Models 2 models
The differential pressure transmitter with double diaphragm sealing can be used for differential pressure and liquid level measurement. Differential pressure transmitter with dual flanges, suitable for high-end applications.
Compare

Continuous / Liquids

Measuring Principle Differential pressure
Characteristic / Application Digital transmitter with metallic measuring diaphragms diaphragm seals and capillaries
Modular transmitter
Long term stability
Enhanced safety via self diagnostic functions
Secondary process barrier
Specialities TempC membrane
Supply / Communication 4...20 mA HART:
10,5...45V DC
Ex ia: 10,5...30V DC
PROFIBUS PA /
FOUDATION Fieldbus:
9...32V DC
Accuracy 0,075% + influence of diaphragm seal
Long term stability 0,05% of URL/year
Ambient temperature -50°C...85°C
(-58°F...185°F)
Process temperature -40°C...400°C
(-40°F...752°F)
Process pressure / max. overpressure limit 160bar (2400 psi)
Pressure measuring range 100mbar...40bar
(1.5psi ... 600 psi)
Main wetted parts Alloy C276
316L
Monel
Tantalum
Process connection Diaphragm seal (Pancakes, threads)
Flanges (DIN, ASME)
Tri-Clamp ISO2852
Hygienic connections
Process connection hygienic Tri-Clamp
DIN11851
NEUMO
Varivent
SMS
DRD
Universal adapter
Max. measurement distance 400m (1312ft) H2O
Communication 4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Certificates / Approvals ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, EAC
Safety approvals SIL
Design approvals EN10204-3.1
NACE MR0175, MR0103
Hygienic approvals 3A, EHEDG
Marine approval GL/ ABS
Options HistoROM/M-Dat
4-line digital display
SS- or Aluminiumhousing
Separate housing
Successor PMD78B
Application limits Measuring cell:
Metal welded

Pressure

Measuring Principle Differential pressure
Characteristic Digital transmitter with metallic measuring diaphragms diaphragm seals and capillaries
Modular transmitter
Long-term stability
Secondary process barrier
enhanced safety via self diagnostic functions.
Supply voltage 4...20 mA HART
10,5...45V DC (Non Ex):
Ex ia: 10,5...30V DC
PROFIBUS PA:
9...32 V DC (Non Ex)
FOUNDATION Fieldbus:
9...32 V DC (Non Ex)
Reference Accuracy 0,075% + influence of diaphragm seal
Long term stability 0.08 % of URL/ year
0.14 % of URL/ 5 years
0.27 % of URL/ 10 years
Process temperature -70°C...400°C
(-94°F...752°F)
Ambient temperature -50°C...85°C
(-58°F...185°F)
Measuring cell 100 mbar...40 bar
(40 inH2O...600 psi)
Smallest calibratable span 5 mbar (0.075 psi)
Vacuum resistance 50 mbar (0.73 psi)
Max. Turn down 100:1
Max. overpressure limit 160 bar
(2400 psi)
Process connection Diaphragm seal (Pancake, threads)
Flanges (DIN, ASME)
Hygienic connections
Tri-Clamp ISO2852
Process connection hygienic Tri-Clamp
DIN11851
NEUMO
Varivent
SMS
DRD
Universal adapter
Material process membrane 316L, AlloyC,
Tantal,
Gold-Rhodium
PTFE
Material gasket None, diaphragm seal welded
Fill fluid Silicone oil,
Inert oil,
Vegetable oil
Low- temperature oil
High- temperature oil
Material housing 316L, Die-cast aluminum
Communication 4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Certificates / Approvals ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, EAC, UK Ex
Safety approvals SIL
Design approvals NACE MR0175
EN10204-3.1
Hygienic approvals 3A, FDA
Marine approvals GL/ ABS
Specialities Diagnostic functions
TempC Membrane
Successor PMD78B

The Deltabar FMD78 differential pressure transmitter uses a metal sensor with dual-capillary diaphragm seals and is mainly used for the continuous differential pressure measurement of liquids, gases, steam and dust in the process industry and the hygiene sector. The built-in HistoROM data module facilitates process and device parameter management. It complies with IEC 61508 and meets SIL3 functional safety requirements.

 

Advantages

Excellent repeatability and long-term stability

High reference accuracy: up to ±0.075%, platinum version: ±0.05%

For flow and differential pressure monitoring to SIL3 requirements, compliant with IEC 61508, certified by TÜV SÜD

HistoROM®/M-DAT memory module

Function monitoring of measuring cell and electronics

Modular continuous measurement of differential pressure, static pressure and pressure (Deltabar S - Deltapilot S, Cerabar S), e.g. replaceable display, universal electronics for pressure and differential pressure measurement

 

Areas of application

For differential pressure, level, volume and mass measurement of liquids

 

Process connections: thread, flange, clamp and hygienic connections

Process temperature: -70 ... +400°C (-94 ... +752°F)

Measuring range: 100mbar ... +16bar (1.5... 240psi);

Accuracy: ±0.075%

International explosion protection approval, WHG overflow protection, hygienic approval, marine approval, SIL

 

 

 

E+H Product Configurator

Please enter the product order code to configure

Product comparison

Please enter the order codes of the products to compare in the boxes below (up to three products)

 

   

Technical documentation

   

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

Source:Endress+Hauserwebsite public information

Model Name
FMD78-1BA7FE1B31BQ 差压变送器
FMD78-ABA7FF1B31AU 差压变送器
Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · Differential Pressure Measurement Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Differential Pressure Measurement.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Differential Pressure Measurement for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · Differential Pressure Measurement Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Differential Pressure Measurement.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Differential Pressure Measurement for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · Differential Pressure Measurement Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Differential Pressure Measurement.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Differential Pressure Measurement for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · Differential Pressure Measurement Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Differential Pressure Measurement.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Differential Pressure Measurement for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.