Technical Data
CompareContinuous / Liquids
| Measuring Principle | Differential pressure |
| Characteristic / Application | Transmitter with metal membrane for differential pressure monitoring in liquids or gases. Intuitive and clear wizard for commissioning |
| Specialities | Bluetooth® Operation and maintenance with SmartBlue App, RFID TAG for easy identification, Plug and play functionalities |
| Supply / Communication | Ex d, Ex e, non-Ex:: 10.5...35V DC Ex i: 10.5...30V DC |
| Accuracy | Standard: up to 0.075 % Platinum: up to 0.055 % |
| Long term stability | 0.05 % of URL/ year 0.13 % of URL/ 5 years 0.23 % of URL/ 10 years |
| Ambient temperature | -40°C...+85°C (-40°F...+185°F) |
| Process temperature | -40°C...+110°C (-40°F...+230°F) |
| Process pressure / max. overpressure limit | 250 bar (3750 psi) |
| Pressure measuring range | 10 mbar.... 40 bar (0.15 psi... 600 psi) |
| Main wetted parts | 316L, AlloyC |
| Process connection | NPT 1/4-18, RC1/4" |
| Communication | 4...20 mA HART PROFINET with Ethernet-APL Bluetooth® wireless technology and app (optional) |
| Certificates / Approvals | ATEX, CSA, IECEx, JPN Ex, KC, INMETRO, NEPSI, UK Ex |
| Safety approvals | SIL |
| Design approvals | EN 10204-3.1, NACE MR0175, NACE MR0103, AD2000 |
| Drinking water approvals | NSF, KTW |
| Application limits | None |
Gas
| Measuring Principle | Differential pressure |
| Product headline | Smart transmitter with metal membrane for differential pressure monitoring. Accurate differential pressure-, level- or flow measurement in liquids or gases. |
| Sensor features | Fill fluid: Inert oil, Silicone oil |
| Transmitter features | Bluetooth® Operation and maintenance Smartblue App, RFID TAG for easy identification, Plug and play functionalities |
| Wetted materials | 316L, Alloy |
| Measuring range | 10 mbar...40 bar (0.15 psi...600 psi) |
| Medium temperature range | -40°C...+110°C (-40°F...+230°F) |
| Ambient temperature range | -40°C...+85°C (-40°F...+185°F) |
| Transmitter housing material | Aluminium |
| Display/Operation | Configuration via local display and operating tools possible Remote display available |
| Outputs | 4...20 mA HART |
| Digital communication | HART |
| Hazardous area approvals | ATEX, CSA, IECEx |
| Functional safety | SIL |
| Material certificates | EN10204-3.1, NACE MR0175, NACE MR0103 AD2000 |
Liquids
| Measuring Principle | Differential pressure |
| Product headline | Smart transmitter with metal membrane for differential pressure monitoring. Accurate differential pressure-, level- or flow measurement in liquids or gases. |
| Sensor features | Fill fluid: Inert oil, Silicone oil |
| Transmitter features | Bluetooth® Operation and maintenance SmartBlue App, RFID TAG for easy identification, Plug and play functionalities |
| Wetted materials | 316L, Alloy |
| Measuring range | 10 mbar...40 bar (0.15 psi...600 psi) |
| Medium temperature range | -40°C...+110°C (-40°F...+230°F) |
| Ambient temperature range | -40°C...+85°C (-40°F...+185°F) |
| Transmitter housing material | Aluminium |
| Display/Operation | Configuration via local display and operating tools possible Remote display available |
| Outputs | 4...20 mA HART |
| Digital communication | HART |
| Hazardous area approvals | ATEX, CSA, IECEx |
| Functional safety | SIL |
| Material certificates | EN10204-3.1, NACE MR0175, NACE MR0103 |
Pressure
| Measuring Principle | Differential pressure |
| Characteristic | Transmitter with metal membrane for differential pressure monitoring in liquids or gases. Intuitive and clear wizard for commissioning |
| Supply voltage | Ex d, Ex e, non-Ex:: 10.5...35V DC Ex i: 10.5...30V DC |
| Reference Accuracy | Standard: up to 0.075 % Platinum: up to 0.055 % |
| Long term stability | 0.05 % of URL/ year 0.13 % of URL/ 5 years 0.23 % of URL/ 10 years |
| Process temperature | -40°C...+110°C (-40°F...+230°F) |
| Ambient temperature | -40°C...+85°C (-40°F...+185°F) |
| Measuring cell | 10 mbar.... 40 bar (0.15 psi... 600 psi) |
| Smallest calibratable span | 0.25 mbar (0.00375 psi) |
| Vacuum resistance | 25 mbar (0.0375 psi) |
| Max. Turn down | 100:1 |
| Max. overpressure limit | 375 bar (5625 psi) |
| Process connection | NPT 1/4-18, RC1/4" |
| Material process membrane | 316L, AlloyC, Gold |
| Material gasket | EPDM, HNBR, FVMQ, |
| Fill fluid | Silicone oil, Inert oil |
| Material housing | Aluminium |
| Communication | 4...20 mA HART PROFINET with Ethernet-APL Bluetooth® wireless technology and app (optional) |
| Certificates / Approvals | ATEX, CSA, IECEx, JPN Ex, KC, INMETRO, NEPSI, UK Ex |
| Safety approvals | SIL |
| Design approvals | EN 10204-3.1, NACE MR0175, NACE MR0103, AD2000 |
| Drinking water approvals | NSF, KTW |
| Specialities | Bluetooth® Operation and maintenance with SmartBlue App, RFID TAG for easy identification, Plug and play functionalities |
PMD55B is a member of the new generation of Deltabar transmitters. The transmitter is robust and supports both on-site and remote operation. The transmitter can be controlled remotely via an app using a mobile device and a secure Bluetooth connection. PMD55B supports on-demand maintenance and significantly improves service efficiency.
The software is equally easy to use. The intuitive operating wizard guides the user step by step through instrument setup, functional safety tests and verification tests, minimizing the risk of operating errors.
Benefits
Wireless remote control of devices within the production area using the SmartBlue App, without interrupting the process
-
Fewer on-site incidents, protecting devices installed at hard-to-reach measuring points
-
Reduced risk of system failure, error-free SIL commissioning and guided functional safety testing of the instrument
Applications
Maximum working pressure 40 bar (600 psi)
-
Maximum working static pressure 250 bar (3750 psi)
-
Highest measurement accuracy of +/-0.055%
Spare Parts & Accessories 80
80 spare parts · click to collapse
| Order code | Description | |
|---|---|---|
| 71487198 | Blind plug, M20, 316L, O-ring EPDMConsists of: blind plug, O-ring PTFE coated 17.0x2.0. Usage: FHX50B, FTL51B, FTL62, FTL63, FTL64, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, NMT81, PMC51B, PMC71B, PMD50, PMD55B, PMD75B, PMD78B, PMP50, PMP51B, PMP71B. | Details |
| 71487199 | Plug: M20, aluminum, EPDM sealing ringConsists of: blind plug, O-ring PTFE coated 17.0x2.0. Usage: FHX50B, FTL51B, FTL62, FTL63, FTL64, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, NMT81, PMC51B, PMC71B, PMD50, PMD55B, PMD75B, PMD78B, PMP50, PMP51B, PMP71B. | Details |
| 71679714 | Blind plug M20, Alu, Ex dConsists of: Plug IEC/ATEX Ex d marking, o-ring PTFE coated 17,0x2,0. Usage: FMG50, FMP51, FMP52, FMP54, FMP55, FMP56, FMP57, FMR51, FMR52, FMR53, FMR54, FMR57, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL64, OFMP50, OFMP51, OFMP57, OFMR51, OFMR54, OFTL41, OFTL51B, PMC51B, PMC71B, PMD50, PMD55B, PMD75B, PMD78B, PMP50, PMP51B, PMP71B. | Details |
| 71487201 | Blind plug, NPT1/2, aluminumConsists of: blind plug, PTFE coated. Usage: FHX50B, FTL51B, FTL62, FTL63, FTL64, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, NMT81, PMC51B, PMC71B, PMD50, PMD55B, PMD75B, PMD78B, PMP50, PMP51B, PMP71B. | Details |
| 71487203 | Blind plug, NPT1/2, 316LConsists of: blind plug, PTFE coated. Usage: FHX50B, FTL51B, FTL62, FTL63, FTL64, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, NMT81, PMC51B, PMC71B, PMD50, PMD55B, PMD75B, PMD78B, PMP50, PMP51B, PMP71B. | Details |
| 71679718 | Blind plug NPT1/2, Alu, Ex dConsists of: Plug IEC/ATEX Ex d marking, PTFE coated. Usage: FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL64, PMC51B, PMC71B, PMD50, PMD55B, PMD75B, PMD78B, PMP50, PMP51B, PMP71B. | Details |
| 71435135 | Cable gland M20, plastic, suitable for models: FTL41, FTL51B, PMC51B, PConsists of: Cable gland, O-ring 17.0 x 2.0 PTFE coated. Usage: FHX50B, FMB70, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL63, FTL64, PMC51B, PMC71B, PMD50, PMD55B, PMD63B, PMD75B, PMD78B, PMP50, PMP51B, PMP63B, PMP71B. | Details |
| 71701449 | Cable gland, blue, M20, plasticConsists of: Cable gland blue M20x1.5, PA, O-ring 17.0 x 2.0 PTFE coated. Usage: FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL51B, FTL62, FTL64, PMC51B, PMC71B, PMD55B, PMD75B, PMD78B, PMP51B, PMP71B. | Details |
| 71435136 | Cable gland M20, nickel-plated brass, suitable for: FMG50, FTL41, FTL51B, PConsists of: Cable gland, O-ring 17.0 x 2.0 PTFE coated. Usage: FHX50B, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL63, FTL64, PMC51B, PMC71B, PMD55B, PMD75B, PMD78B, PMP51B, PMP71B. | Details |
| 71435137 | Cable gland M20, 316L, suitable for models: FMG50, FTL51B, PMC51BConsists of: Cable gland, O-ring 17.0 x 2.0 PTFE coated. Usage: FHX50B, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL51B, FTL62, FTL63, FTL64, PMC51B, PMC71B, PMD55B, PMD75B, PMD78B, PMP51B, PMP71B. | Details |
| 71440660 | M20x1.5-G1/2 adapter, aluminumConsists of: Adapter set, O-ring, 17.0 x 2.0 PTFE coated. Usage: FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL63, FTL64, PMC51B, PMC71B, PMD50, PMD55B, PMD75B, PMD78B, PMP50, PMP51B, PMP71B. | Details |
| 71435138 | Plug connector M20, nickel-plated brass, suitable for: screw-in thread, FMG50Usage: M12 screw-in thread, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL51B, FTL62, FTL64, PMC51B, PMC71B, PMD55B, PMD75B, PMD78B, PMP51B, PMP71B. | Details |
| 71435139 | M12 plug, 316L, APL, housing sideUsage: M12 screw-in thread. Usage: FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL51B, FTL62, FTL63, FTL64, FTM50, FTM51, FTM52, PMC51B, PMC71B, PMD55B, PMD75B, PMD78B, PMP51B, PMP71B. | Details |
| 52006263 | Process connection | Socket for plug 4p-125V, 4A-M12M12 插头 自连接 M12转成格兰 | Details |
| 71439098 | Connector HAN7D, 90°, IP65, suitable for: FMG50, PMC51BUsage: FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, PMC51B, PMC71B, PMD55B, PMD75B, PMD78B, PMP51B, PMP71B. | Details |
| 71474251 | Enclosure grounding terminal L+PConsists of: spring washer, screw, earth handle, clamp. Usage Liquiphant: Only for digital communication. Usage: FHX50B, FMG50, PMD50, PMD55B, PMD63B, PMD75B, PMD78B, PMC51B, PMC71B, PMP50, PMP51B, PMP63B, PMP71B, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL51B, FTL62, FTL63, FTL64. | Details |
| 71435116 | Housing cover, aluminum, sealed cover, O-ring, HNBR. Suitable for models: FMG50, FTL41, FTLSealing ring, HNBR. Usage: FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL63, FTL64, PMC51B, PMC71B, PMD55B, PMD75B, PMD78B, PMP51B, PMP71B. | Details |
| 71435118 | Housing cover, aluminum, closed cover, Ex d seal, HNBR. Suitable for: FMG50, FTL4Sealing ring, HNBR. Usage: FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL63, FTL64, NMT81, PMC51B, PMC71B, PMD55B, PMD75B, PMD78B, PMP51B, PMP71B. | Details |
| 71439086 | Cover red Alu, closed, Ex dSealing ring: HNBR. Usage: FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, PMC51B, PMC71B,PMD55B, PMD75B, PMD78B, PMP51B, PMP71B. | Details |
| 71439089 | Aluminum cover with glass viewing windowSealing ring: HNBR. Sight glass: plastic. Usage: FHX50B, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL63, FTL64, NMT81, PMC51B, PMC71B, PMD55B, PMD75B, PMD78B, PMP51B, PMP71B, QWX43. | Details |
Configurator / Comparison
Source: Endress+Hauserpublic information from the website
Measuring principle video
Click to playProduct Videos
Case Studies
Municipal Wastewater Treatment · Differential Pressure Measurement — Application Case
Project Overview
The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Differential Pressure Measurement properly configured on the existing plant, with the aim of differential pressure for flow and filter monitoring.
Technical Challenges
What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Differential Pressure Measurement configuration has to involve checking static pressure limit, overload margin and impulse lines.
Configuration
Supply and installation were organised through the pressure range: pressure solution matched to process pressure and temperature. On site this meant checking static pressure limit, overload margin and impulse lines, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.
Performance
After commissioning the outcome is filters changed on pressure drop, using cartridges to their full life, and the readings are now used for process tuning.
Food & Beverage · Differential Pressure Measurement — Application Case
Site Conditions
This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was differential pressure for flow and filter monitoring.
The Problem
The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means checking static pressure limit, overload margin and impulse lines.
What We Did
We took a pressure range approach — pressure solution matched to process pressure and temperature. Delivery was built around checking static pressure limit, overload margin and impulse lines, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.
Operating Outcome
In service the system performs as intended — filters changed on pressure drop, using cartridges to their full life, with routine maintenance falling noticeably.
Chemical & Pharmaceutical · Differential Pressure Measurement — Application Case
Application Context
reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Differential Pressure Measurement, focusing on differential pressure for flow and filter monitoring.
Process Constraints
corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Differential Pressure Measurement specification must therefore cover checking static pressure limit, overload margin and impulse lines.
Delivery Approach
Delivery was handled as the pressure range — pressure solution matched to process pressure and temperature. Execution centred on checking static pressure limit, overload margin and impulse lines, together with Ex certification and GMP traceability of records.
Field Results
Operation shows the benefit clearly — filters changed on pressure drop, using cartridges to their full life, with confidence in this measuring point improving markedly.
Power & Energy · Differential Pressure Measurement — Application Case
Customer Profile
The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Differential Pressure Measurement; the focus is differential pressure for flow and filter monitoring.
Key Difficulties
Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with checking static pressure limit, overload margin and impulse lines.
Implementation
The scope ran through the pressure range: pressure solution matched to process pressure and temperature. Technically it hinges on checking static pressure limit, overload margin and impulse lines, and on these requirements: compliance with power-industry codes and unit availability targets.
Customer Benefit
In practice this means filters changed on pressure drop, using cartridges to their full life, which cut the workload on the site maintenance team.
Related Products
Endress+HauserDeltabar M PMD55
Endress+HauserDeltabar S PMD75
Endress+HauserDeltabar PMD78B
Endress+HauserDeltabar FMD72
Endress+HauserDeltabar S FMD77
Endress+HauserDeltabar FMD71
Endress+HauserDeltabar PMD75B
Endress+Hauser