Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

PMD55B differential pressure transmitter

PMD55B differential pressure transmitter
Deltabar PMD55B
Configurable Models 20 models
Intelligent transmitter with metal diaphragm sensor, realizing differential pressure monitoring of liquids and gases for high-precision measurement of liquids and gases
Compare

Continuous / Liquids

Measuring Principle Differential pressure
Characteristic / Application Transmitter with metal membrane for differential pressure monitoring in liquids or gases.
Intuitive and clear wizard for commissioning
Specialities Bluetooth® Operation and maintenance with SmartBlue App,
RFID TAG for easy identification,
Plug and play functionalities
Supply / Communication Ex d, Ex e, non-Ex::
10.5...35V DC
Ex i: 10.5...30V DC
Accuracy Standard:
up to 0.075 %
Platinum:
up to 0.055 %
Long term stability 0.05 % of URL/ year
0.13 % of URL/ 5 years
0.23 % of URL/ 10 years
Ambient temperature -40°C...+85°C (-40°F...+185°F)
Process temperature -40°C...+110°C (-40°F...+230°F)
Process pressure / max. overpressure limit 250 bar (3750 psi)
Pressure measuring range 10 mbar.... 40 bar (0.15 psi... 600 psi)
Main wetted parts 316L, AlloyC
Process connection NPT 1/4-18, RC1/4"
Communication 4...20 mA HART
PROFINET with Ethernet-APL
Bluetooth® wireless
technology and app (optional)
Certificates / Approvals ATEX, CSA, IECEx, JPN Ex, KC, INMETRO, NEPSI, UK Ex
Safety approvals SIL
Design approvals EN 10204-3.1,
NACE MR0175,
NACE MR0103,
AD2000
Drinking water approvals NSF, KTW
Application limits None

Gas

Measuring Principle Differential pressure
Product headline Smart transmitter with metal membrane for differential pressure monitoring.
Accurate differential pressure-, level- or flow measurement in liquids or gases.
Sensor features Fill fluid:
Inert oil,
Silicone oil
Transmitter features Bluetooth® Operation and maintenance Smartblue App,
RFID TAG for easy identification,
Plug and play functionalities
Wetted materials 316L, Alloy
Measuring range 10 mbar...40 bar
(0.15 psi...600 psi)
Medium temperature range -40°C...+110°C
(-40°F...+230°F)
Ambient temperature range -40°C...+85°C
(-40°F...+185°F)
Transmitter housing material Aluminium
Display/Operation Configuration via local display and operating tools possible
Remote display available
Outputs 4...20 mA HART
Digital communication HART
Hazardous area approvals ATEX, CSA, IECEx
Functional safety SIL
Material certificates EN10204-3.1,
NACE MR0175,
NACE MR0103
AD2000

Liquids

Measuring Principle Differential pressure
Product headline Smart transmitter with metal membrane for differential pressure monitoring.
Accurate differential pressure-, level- or flow measurement in liquids or gases.
Sensor features Fill fluid:
Inert oil,
Silicone oil
Transmitter features Bluetooth® Operation and maintenance SmartBlue App,
RFID TAG for easy identification,
Plug and play functionalities
Wetted materials 316L, Alloy
Measuring range 10 mbar...40 bar
(0.15 psi...600 psi)
Medium temperature range -40°C...+110°C
(-40°F...+230°F)
Ambient temperature range -40°C...+85°C
(-40°F...+185°F)
Transmitter housing material Aluminium
Display/Operation Configuration via local display and operating tools possible
Remote display available
Outputs 4...20 mA HART
Digital communication HART
Hazardous area approvals ATEX, CSA, IECEx
Functional safety SIL
Material certificates EN10204-3.1,
NACE MR0175,
NACE MR0103

Pressure

Measuring Principle Differential pressure
Characteristic Transmitter with metal membrane for differential pressure monitoring in liquids or gases.
Intuitive and clear wizard for commissioning
Supply voltage Ex d, Ex e, non-Ex::
10.5...35V DC
Ex i: 10.5...30V DC
Reference Accuracy Standard:
up to 0.075 %
Platinum:
up to 0.055 %
Long term stability 0.05 % of URL/ year
0.13 % of URL/ 5 years
0.23 % of URL/ 10 years
Process temperature -40°C...+110°C (-40°F...+230°F)
Ambient temperature -40°C...+85°C (-40°F...+185°F)
Measuring cell 10 mbar.... 40 bar (0.15 psi... 600 psi)
Smallest calibratable span 0.25 mbar (0.00375 psi)
Vacuum resistance 25 mbar (0.0375 psi)
Max. Turn down 100:1
Max. overpressure limit 375 bar (5625 psi)
Process connection NPT 1/4-18, RC1/4"
Material process membrane 316L, AlloyC,
Gold
Material gasket EPDM, HNBR, FVMQ,
Fill fluid Silicone oil,
Inert oil
Material housing Aluminium
Communication 4...20 mA HART
PROFINET with Ethernet-APL
Bluetooth® wireless
technology and app (optional)
Certificates / Approvals ATEX, CSA, IECEx, JPN Ex, KC, INMETRO, NEPSI, UK Ex
Safety approvals SIL
Design approvals EN 10204-3.1,
NACE MR0175,
NACE MR0103,
AD2000
Drinking water approvals NSF, KTW
Specialities Bluetooth® Operation and maintenance with SmartBlue App,
RFID TAG for easy identification,
Plug and play functionalities

PMD55B is a member of the new generation of Deltabar transmitters. The transmitter is robust and supports both on-site and remote operation. The transmitter can be controlled remotely via an app using a mobile device and a secure Bluetooth connection. PMD55B supports on-demand maintenance and significantly improves service efficiency.
The software is equally easy to use. The intuitive operating wizard guides the user step by step through instrument setup, functional safety tests and verification tests, minimizing the risk of operating errors.

Benefits
Wireless remote control of devices within the production area using the SmartBlue App, without interrupting the process

  • Fewer on-site incidents, protecting devices installed at hard-to-reach measuring points

  • Reduced risk of system failure, error-free SIL commissioning and guided functional safety testing of the instrument

Applications
Maximum working pressure 40 bar (600 psi)

  • Maximum working static pressure 250 bar (3750 psi)

  • Highest measurement accuracy of +/-0.055%

 

Spare Parts & Accessories 80

80 spare parts · click to collapse
Order codeDescription
71487198Blind plug, M20, 316L, O-ring EPDMConsists of: blind plug, O-ring PTFE coated 17.0x2.0. Usage: FHX50B, FTL51B, FTL62, FTL63, FTL64, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, NMT81, PMC51B, PMC71B, PMD50, PMD55B, PMD75B, PMD78B, PMP50, PMP51B, PMP71B.Details
71487199Plug: M20, aluminum, EPDM sealing ringConsists of: blind plug, O-ring PTFE coated 17.0x2.0. Usage: FHX50B, FTL51B, FTL62, FTL63, FTL64, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, NMT81, PMC51B, PMC71B, PMD50, PMD55B, PMD75B, PMD78B, PMP50, PMP51B, PMP71B.Details
71679714Blind plug M20, Alu, Ex dConsists of: Plug IEC/ATEX Ex d marking, o-ring PTFE coated 17,0x2,0. Usage: FMG50, FMP51, FMP52, FMP54, FMP55, FMP56, FMP57, FMR51, FMR52, FMR53, FMR54, FMR57, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL64, OFMP50, OFMP51, OFMP57, OFMR51, OFMR54, OFTL41, OFTL51B, PMC51B, PMC71B, PMD50, PMD55B, PMD75B, PMD78B, PMP50, PMP51B, PMP71B.Details
71487201Blind plug, NPT1/2, aluminumConsists of: blind plug, PTFE coated. Usage: FHX50B, FTL51B, FTL62, FTL63, FTL64, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, NMT81, PMC51B, PMC71B, PMD50, PMD55B, PMD75B, PMD78B, PMP50, PMP51B, PMP71B.Details
71487203Blind plug, NPT1/2, 316LConsists of: blind plug, PTFE coated. Usage: FHX50B, FTL51B, FTL62, FTL63, FTL64, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, NMT81, PMC51B, PMC71B, PMD50, PMD55B, PMD75B, PMD78B, PMP50, PMP51B, PMP71B.Details
71679718Blind plug NPT1/2, Alu, Ex dConsists of: Plug IEC/ATEX Ex d marking, PTFE coated. Usage: FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL64, PMC51B, PMC71B, PMD50, PMD55B, PMD75B, PMD78B, PMP50, PMP51B, PMP71B.Details
71435135Cable gland M20, plastic, suitable for models: FTL41, FTL51B, PMC51B, PConsists of: Cable gland, O-ring 17.0 x 2.0 PTFE coated. Usage: FHX50B, FMB70, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL63, FTL64, PMC51B, PMC71B, PMD50, PMD55B, PMD63B, PMD75B, PMD78B, PMP50, PMP51B, PMP63B, PMP71B.Details
71701449Cable gland, blue, M20, plasticConsists of: Cable gland blue M20x1.5, PA, O-ring 17.0 x 2.0 PTFE coated. Usage: FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL51B, FTL62, FTL64, PMC51B, PMC71B, PMD55B, PMD75B, PMD78B, PMP51B, PMP71B.Details
71435136Cable gland M20, nickel-plated brass, suitable for: FMG50, FTL41, FTL51B, PConsists of: Cable gland, O-ring 17.0 x 2.0 PTFE coated. Usage: FHX50B, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL63, FTL64, PMC51B, PMC71B, PMD55B, PMD75B, PMD78B, PMP51B, PMP71B.Details
71435137Cable gland M20, 316L, suitable for models: FMG50, FTL51B, PMC51BConsists of: Cable gland, O-ring 17.0 x 2.0 PTFE coated. Usage: FHX50B, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL51B, FTL62, FTL63, FTL64, PMC51B, PMC71B, PMD55B, PMD75B, PMD78B, PMP51B, PMP71B.Details
71440660M20x1.5-G1/2 adapter, aluminumConsists of: Adapter set, O-ring, 17.0 x 2.0 PTFE coated. Usage: FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL63, FTL64, PMC51B, PMC71B, PMD50, PMD55B, PMD75B, PMD78B, PMP50, PMP51B, PMP71B.Details
71435138Plug connector M20, nickel-plated brass, suitable for: screw-in thread, FMG50Usage: M12 screw-in thread, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL51B, FTL62, FTL64, PMC51B, PMC71B, PMD55B, PMD75B, PMD78B, PMP51B, PMP71B.Details
71435139M12 plug, 316L, APL, housing sideUsage: M12 screw-in thread. Usage: FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL51B, FTL62, FTL63, FTL64, FTM50, FTM51, FTM52, PMC51B, PMC71B, PMD55B, PMD75B, PMD78B, PMP51B, PMP71B.Details
52006263Process connection | Socket for plug 4p-125V, 4A-M12M12 插头 自连接 M12转成格兰Details
71439098Connector HAN7D, 90°, IP65, suitable for: FMG50, PMC51BUsage: FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, PMC51B, PMC71B, PMD55B, PMD75B, PMD78B, PMP51B, PMP71B.Details
71474251Enclosure grounding terminal L+PConsists of: spring washer, screw, earth handle, clamp. Usage Liquiphant: Only for digital communication. Usage: FHX50B, FMG50, PMD50, PMD55B, PMD63B, PMD75B, PMD78B, PMC51B, PMC71B, PMP50, PMP51B, PMP63B, PMP71B, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL51B, FTL62, FTL63, FTL64.Details
71435116Housing cover, aluminum, sealed cover, O-ring, HNBR. Suitable for models: FMG50, FTL41, FTLSealing ring, HNBR. Usage: FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL63, FTL64, PMC51B, PMC71B, PMD55B, PMD75B, PMD78B, PMP51B, PMP71B.Details
71435118Housing cover, aluminum, closed cover, Ex d seal, HNBR. Suitable for: FMG50, FTL4Sealing ring, HNBR. Usage: FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL63, FTL64, NMT81, PMC51B, PMC71B, PMD55B, PMD75B, PMD78B, PMP51B, PMP71B.Details
71439086Cover red Alu, closed, Ex dSealing ring: HNBR. Usage: FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, PMC51B, PMC71B,PMD55B, PMD75B, PMD78B, PMP51B, PMP71B.Details
71439089Aluminum cover with glass viewing windowSealing ring: HNBR. Sight glass: plastic. Usage: FHX50B, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL63, FTL64, NMT81, PMC51B, PMC71B, PMD55B, PMD75B, PMD78B, PMP51B, PMP71B, QWX43.Details

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

Source: Endress+Hauserpublic information from the website

Measuring principle video

Click to play
48 models · click to collapse
Diagnostic codes(41 条)→
All documents for this model
6 documents · click to expand
BA

BA Deltabar PMD55B Chinese

Rev. 0725 80 pages
Preview
BA

BA Deltabar PMD55B Chinese

Rev. 0325 84 pages
Preview
BA

BA Deltabar PMD55B English

Rev. 0725 84 pages
Preview
BA

BA Deltabar PMD55B English

Rev. 0325 92 pages
Preview
TI

TI Deltabar PMD55B Chinese

Rev. 0925 52 pages
Preview
TI

TI Deltabar PMD55B English

Rev. 0925 52 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Differential Pressure Measurement — Application Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Differential Pressure Measurement properly configured on the existing plant, with the aim of differential pressure for flow and filter monitoring.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Differential Pressure Measurement configuration has to involve checking static pressure limit, overload margin and impulse lines.

Configuration

Supply and installation were organised through the pressure range: pressure solution matched to process pressure and temperature. On site this meant checking static pressure limit, overload margin and impulse lines, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is filters changed on pressure drop, using cartridges to their full life, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · Differential Pressure Measurement — Application Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was differential pressure for flow and filter monitoring.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means checking static pressure limit, overload margin and impulse lines.

What We Did

We took a pressure range approach — pressure solution matched to process pressure and temperature. Delivery was built around checking static pressure limit, overload margin and impulse lines, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — filters changed on pressure drop, using cartridges to their full life, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Differential Pressure Measurement — Application Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Differential Pressure Measurement, focusing on differential pressure for flow and filter monitoring.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Differential Pressure Measurement specification must therefore cover checking static pressure limit, overload margin and impulse lines.

Delivery Approach

Delivery was handled as the pressure range — pressure solution matched to process pressure and temperature. Execution centred on checking static pressure limit, overload margin and impulse lines, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — filters changed on pressure drop, using cartridges to their full life, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · Differential Pressure Measurement — Application Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Differential Pressure Measurement; the focus is differential pressure for flow and filter monitoring.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with checking static pressure limit, overload margin and impulse lines.

Implementation

The scope ran through the pressure range: pressure solution matched to process pressure and temperature. Technically it hinges on checking static pressure limit, overload margin and impulse lines, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means filters changed on pressure drop, using cartridges to their full life, which cut the workload on the site maintenance team.