PMD75B differential pressure transmitter

PMD75B differential pressure transmitter
Deltabar PMD75B
Configurable Models 18 models
Intelligent pressure transmitters can detect process abnormalities in a timely manner, such as blockages in pressure pipes
Compare

Continuous / Liquids

Measuring Principle Differential pressure
Characteristic / Application Differential pressure transmitter which detects process anomalies like plugged impulse lines.
Intuitive and clear wizards for commissioning, proof tests and verification.
Specialities Heartbeat Technology,
Bluetooth® Operation and maintenance with SmartBlue App,
LED Module,
RFID TAG for easy identification,
Plug and play functionalities
HistoROM
Supply / Communication Ex d, Ex e, non-Ex:
10.5...35V DC
Ex i:
10.5...30V DC
Accuracy Standard:
up to 0.05 %
Platinum:
up to 0.035 %
Long term stability 0.025 % of URL/ year
0.05 % of URL/ 5 years
0.10 % of URL/ 10 years
Ambient temperature -54°C...+85°C
(-65°F...+185°F)
Process temperature -40°C...+110°C
(-40°F...+230°F)
Process pressure / max. overpressure limit 420 bar (6300 psi)
Pressure measuring range 10 mbar...250 bar
(0.15 psi...3750 psi)
Main wetted parts 316L, AlloyC,
Tantal, Monel,
Gold
Process connection NPT1/4-18,
RC1/4"
Max. measurement distance 400 m (1,312 ft) H2O
Communication 4...20 mA HART
PROFIBUS PA
PROFINET with Ethernet-APL
Bluetooth® wireless
technology and app (optional)
Certificates / Approvals ATEX, CSA, IECEx, JPN Ex, INMETRO, NEPSI, UK Ex
Safety approvals SIL
Design approvals EN 10204-3.1,
NACE MR0175,
NACE MR0103
Drinking water approvals NSF, KTW
Options Touch control display
Application limits None

Gas

Measuring Principle Differential pressure
Product headline Differential pressure transmitter which detects process anomalies like plugged impulse lines,
Intuitive and clear wizards for commissioning, proof tests and verification
Sensor features Fill fluid:
Silicone oil,
Inert oil
Transmitter features LED Module,
RFID TAG for easy identification,
Plug and play functionalities,
HistoROM
Wetted materials 316L,
AlloyC,
Tantal,
Monel,
Gold
Measured variables Differential pressure
Max. measurement error Standard:
up to 0.05 %
Platinum:
up to 0.035 %
Measuring range 10 mbar...250 bar
(0.15 psi...3750 psi)
Max. process pressure 420 bar (6300 psi)
Ambient temperature range -40°C...+85°C
(-40°F...+185°F)
Transmitter housing material Aluminium, 316L
Display/Operation 4-line backlit display with touch control (operation from outside)
Bluetooth® Operation and maintenance SmartBlue App,
Configuration via local display and operating tools possible
Outputs 4...20 mA HART
Digital communication HART
Hazardous area approvals ATEX, CSA, IECEx, JPN Ex, INMETRO, NEPSI, UK Ex
Functional safety SIL
Metrological approvals and certificates Heartbeat Technology
Pressure approvals and certificates CRN
Material certificates EN10204-3.1,
NACE MR0175,
NACE MR0103

Liquids

Measuring Principle Differential pressure
Product headline Differential pressure transmitter which detects process anomalies like plugged impulse lines,
Intuitive and clear wizards for commissioning, proof tests and verification
Sensor features Fill fluid:
Silicone oil,
Inert oil
Transmitter features LED Module,
RFID TAG for easy identification,
Plug and play functionalities,
HistoROM
Wetted materials 316L,
AlloyC,
Tantal,
Monel,
Gold
Measured variables Differential pressure
Max. measurement error Standard:
up to 0.05 %
Platinum:
up to 0.035 %
Measuring range 10 mbar...250 bar
(0.15 psi...3750 psi)
Max. process pressure 420 bar (6300 psi)
Ambient temperature range -40°C...+85°C
(-40°F...+185°F)
Transmitter housing material Aluminium, 316L
Display/Operation 4-line backlit display with touch control (operation from outside)
Bluetooth® Operation and maintenance SmartBlue App,
Configuration via local display and operating tools possible
Outputs 4...20 mA HART
Digital communication HART
Hazardous area approvals ATEX, CSA, IECEx, JPN Ex, INMETRO, NEPSI, UK Ex
Functional safety SIL
Metrological approvals and certificates Heartbeat Technology
Pressure approvals and certificates CRN
Material certificates EN10204-3.1,
NACE MR0175,
NACE MR0103

Pressure

Measuring Principle Differential pressure
Characteristic Differential pressure transmitter which detects process anomalies like plugged impulse lines.
Intuitive and clear wizards for commissioning, proof tests and verification.
Supply voltage Ex d, Ex e, non-Ex:
10.5...35V DC
Ex i: 10.5...30V DC
Reference Accuracy Standard:
up to 0.05 %
Platinum:
up to 0.035 %
Long term stability 0.025 % of URL/ year
0.05 % of URL/ 5 years
0.10 % of URL/ 10 years
Process temperature -40°C...+110°C
(-40°F...+230°F)
Ambient temperature -40°C...+85°C
(-40°F...+185°F)
Measuring cell 10 mbar...250 bar
(0.15 psi...3750 psi)
Smallest calibratable span 0.25 mbar (0.00375 psi)
Vacuum resistance 25 mbar (0.0375 psi)
Max. Turn down 100:1
Max. overpressure limit 630 bar (9,450 psi)
Process connection NPT1/4-18
RC1/4"
Material process membrane 316L, AlloyC,
Tantal,
Monel,
Gold
Material gasket PTFE, FKM, EPDM, FFKM
Fill fluid Silicone oil,
Inert oil
Material housing Aluminium, 316L
Communication 4...20 mA HART
PROFIBUS PA
PROFINET with Ethernet-APL
Bluetooth® wireless
technology and app (optional)
Certificates / Approvals ATEX, CSA, IECEx, JPN Ex, INMETRO, NEPSI, UK Ex
Safety approvals SIL
Design approvals EN10204-3.1,
NACE MR0103,
NACE MR0175
Drinking water approvals NSF, KTW
Specialities Heartbeat Technology,
Bluetooth® Operation and maintenance SmartBlue App,
LED Module,
RFID TAG for easy identification,
Plug and play functionalities,
HistoROM

Steam

Measuring Principle Differential pressure
Product headline Differential pressure transmitter which detects process anomalies like plugged impulse lines,
Intuitive and clear wizards for commissioning, proof tests and verification
Sensor features Fill fluid:
Silicone oil,
Inert oil
Transmitter features LED Module,
RFID TAG for easy identification,
Plug and play functionalities,
HistoROM
Wetted materials 316L,
AlloyC,
Tantal,
Monel,
Gold
Measured variables Differential pressure
Max. measurement error Standard:
up to 0.05 %
Platinum:
up to 0.035 %
Measuring range 10 mbar...250 bar
(0.15 psi...3750 psi)
Max. process pressure 420 bar (6300 psi)
Ambient temperature range -40°C...+85°C
(-40°F...+185°F)
Transmitter housing material Aluminium, 316L
Display/Operation 4-line backlit display with touch control (operation from outside)
Bluetooth® Operation and maintenance SmartBlue App,
Configuration via local display and operating tools possible
Outputs 4...20 mA HART
Digital communication HART
Hazardous area approvals ATEX, CSA, IECEx, JPN Ex, INMETRO, NEPSI, UK Ex
Functional safety SIL
Metrological approvals and certificates Heartbeat Technology
Pressure approvals and certificates CRN
Material certificates EN10204-3.1,
NACE MR0175,
NACE MR0103

Applications

PMD75B is a member of the new generation of Deltabar transmitters. The transmitter is robust and features a secure Bluetooth connection, allowing remote operation of the instrument via a mobile device with the app installed. It supports on-demand maintenance and increases plant availability.
The software is very easy to use. The intuitive operating wizard guides the user step by step through instrument setup, functional safety tests and verification tests.
Heartbeat Technology provides self-verification and self-monitoring functions that can detect process anomalies, such as blocked impulse lines.

  • Maximum working pressure 250 bar (3750 psi) (gauge/absolute) and 40 bar (600 psi) (differential)

  • Maximum working static pressure 420 bar (6300 psi)

  • Highest measurement accuracy of +/- 0.035%

Benefits

  • Heartbeat Technology verifies instrument health without interrupting the process. Increases plant availability.

  • Clear instrument status indication: the instrument immediately switches from green to red display as soon as a diagnostic message occurs

  • Reduced risk of system failure, error-free SIL commissioning and guided functional safety testing of the instrument

  • Wireless remote control of devices in hard-to-reach areas using the SmartBlue App

 

Spare Parts & Accessories 95

95 spare parts · click to collapse
Order codeDescription
71487198Blind plug, M20, 316L, O-ring EPDMConsists of: blind plug, O-ring PTFE coated 17.0x2.0. Usage: FHX50B, FTL51B, FTL62, FTL63, FTL64, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, NMT81, PMC51B, PMC71B, PMD50, PMD55B, PMD75B, PMD78B, PMP50, PMP51B, PMP71B.Details
71487199Plug: M20, aluminum, EPDM sealing ringConsists of: blind plug, O-ring PTFE coated 17.0x2.0. Usage: FHX50B, FTL51B, FTL62, FTL63, FTL64, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, NMT81, PMC51B, PMC71B, PMD50, PMD55B, PMD75B, PMD78B, PMP50, PMP51B, PMP71B.Details
71679712Blind plug M20, 316L, Ex dConsists of: Plug IEC/ATEX Ex d marking o-ring PTFE coated 17,0x2,0. Usage: FMG50, FMP51, FMP52, FMP54, FMP55, FMP56, FMP57, FMR51, FMR52, FMR53, FMR54, FMR57, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL62, FTL64, OFMP51, OFMP57, OFMR51,OFMR54, OFTL51B, PMC71B, PMD50, PMD75B, PMD78B, PMP50, PMP71B.Details
71679714Blind plug M20, Alu, Ex dConsists of: Plug IEC/ATEX Ex d marking, o-ring PTFE coated 17,0x2,0. Usage: FMG50, FMP51, FMP52, FMP54, FMP55, FMP56, FMP57, FMR51, FMR52, FMR53, FMR54, FMR57, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL64, OFMP50, OFMP51, OFMP57, OFMR51, OFMR54, OFTL41, OFTL51B, PMC51B, PMC71B, PMD50, PMD55B, PMD75B, PMD78B, PMP50, PMP51B, PMP71B.Details
71487201Blind plug, NPT1/2, aluminumConsists of: blind plug, PTFE coated. Usage: FHX50B, FTL51B, FTL62, FTL63, FTL64, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, NMT81, PMC51B, PMC71B, PMD50, PMD55B, PMD75B, PMD78B, PMP50, PMP51B, PMP71B.Details
71487203Blind plug, NPT1/2, 316LConsists of: blind plug, PTFE coated. Usage: FHX50B, FTL51B, FTL62, FTL63, FTL64, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, NMT81, PMC51B, PMC71B, PMD50, PMD55B, PMD75B, PMD78B, PMP50, PMP51B, PMP71B.Details
71679715Blind plug NPT1/2, 316L, Ex dConsists of: Plug IEC/ATEX Ex d marking, PTFE coated. Usage: FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL64, PMC71B, PMD50, PMD75B, PMD78B, PMP71B, PMP50.Details
71679718Blind plug NPT1/2, Alu, Ex dConsists of: Plug IEC/ATEX Ex d marking, PTFE coated. Usage: FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL64, PMC51B, PMC71B, PMD50, PMD55B, PMD75B, PMD78B, PMP50, PMP51B, PMP71B.Details
71435135Cable gland M20, plastic, suitable for models: FTL41, FTL51B, PMC51B, PConsists of: Cable gland, O-ring 17.0 x 2.0 PTFE coated. Usage: FHX50B, FMB70, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL63, FTL64, PMC51B, PMC71B, PMD50, PMD55B, PMD63B, PMD75B, PMD78B, PMP50, PMP51B, PMP63B, PMP71B.Details
71701449Cable gland, blue, M20, plasticConsists of: Cable gland blue M20x1.5, PA, O-ring 17.0 x 2.0 PTFE coated. Usage: FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL51B, FTL62, FTL64, PMC51B, PMC71B, PMD55B, PMD75B, PMD78B, PMP51B, PMP71B.Details
71435136Cable gland M20, nickel-plated brass, suitable for: FMG50, FTL41, FTL51B, PConsists of: Cable gland, O-ring 17.0 x 2.0 PTFE coated. Usage: FHX50B, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL63, FTL64, PMC51B, PMC71B, PMD55B, PMD75B, PMD78B, PMP51B, PMP71B.Details
71435137Cable gland M20, 316L, suitable for models: FMG50, FTL51B, PMC51BConsists of: Cable gland, O-ring 17.0 x 2.0 PTFE coated. Usage: FHX50B, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL51B, FTL62, FTL63, FTL64, PMC51B, PMC71B, PMD55B, PMD75B, PMD78B, PMP51B, PMP71B.Details
71440660M20x1.5-G1/2 adapter, aluminumConsists of: Adapter set, O-ring, 17.0 x 2.0 PTFE coated. Usage: FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL63, FTL64, PMC51B, PMC71B, PMD50, PMD55B, PMD75B, PMD78B, PMP50, PMP51B, PMP71B.Details
71440667M20x1.5-G1/2 adapter, 316LConsists of: Adapter, O-Ring 17.0 x 2.0 PTFE coated. Usage: FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL64, PMC51B, PMC71B, PMD50, PMD55B, PMD75B, PMD78B, PMP50, PMP51B, PMP71B.Details
71435138Plug connector M20, nickel-plated brass, suitable for: screw-in thread, FMG50Usage: M12 screw-in thread, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL51B, FTL62, FTL64, PMC51B, PMC71B, PMD55B, PMD75B, PMD78B, PMP51B, PMP71B.Details
71435139M12 plug, 316L, APL, housing sideUsage: M12 screw-in thread. Usage: FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL51B, FTL62, FTL63, FTL64, FTM50, FTM51, FTM52, PMC51B, PMC71B, PMD55B, PMD75B, PMD78B, PMP51B, PMP71B.Details
52006263Process connection | Socket for plug 4p-125V, 4A-M12M12 插头 自连接 M12转成格兰Details
71439098Connector HAN7D, 90°, IP65, suitable for: FMG50, PMC51BUsage: FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, PMC51B, PMC71B, PMD55B, PMD75B, PMD78B, PMP51B, PMP71B.Details
71474251Enclosure grounding terminal L+PConsists of: spring washer, screw, earth handle, clamp. Usage Liquiphant: Only for digital communication. Usage: FHX50B, FMG50, PMD50, PMD55B, PMD63B, PMD75B, PMD78B, PMC51B, PMC71B, PMP50, PMP51B, PMP63B, PMP71B, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL51B, FTL62, FTL63, FTL64.Details
71435116Housing cover, aluminum, sealed cover, O-ring, HNBR. Suitable for models: FMG50, FTL41, FTLSealing ring, HNBR. Usage: FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL63, FTL64, PMC51B, PMC71B, PMD55B, PMD75B, PMD78B, PMP51B, PMP71B.Details

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

 

 

   

Orifice plate flowmeter measurement principle video

Click to play

   

Pitot tube measurement principle video

Click to play

Source: Endress+Hauserpublic information from the website

18 models · click to collapse
All documents for this model
8 documents · click to expand
BA

BA Deltabar PMD75B Chinese

Rev. 0725 84 pages
Preview
BA

BA Deltabar PMD75B Chinese

Rev. 0325 92 pages
Preview
BA

BA Deltabar PMD75B Chinese

Rev. 0125 80 pages
Preview
BA

BA Deltabar PMD75B English

Rev. 0725 96 pages
Preview
BA

BA Deltabar PMD75B English

Rev. 0325 96 pages
Preview
BA

BA Deltabar PMD75B English

Rev. 0125 84 pages
Preview
TI

TI Deltabar PMD75B Chinese

Rev. 0925 60 pages
Preview
TI

TI Deltabar PMD75B English

Rev. 0925 64 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Differential Pressure Measurement — Application Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Differential Pressure Measurement properly configured on the existing plant, with the aim of differential pressure for flow and filter monitoring.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Differential Pressure Measurement configuration has to involve checking static pressure limit, overload margin and impulse lines.

Configuration

Supply and installation were organised through the pressure range: pressure solution matched to process pressure and temperature. On site this meant checking static pressure limit, overload margin and impulse lines, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is filters changed on pressure drop, using cartridges to their full life, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · Differential Pressure Measurement — Application Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was differential pressure for flow and filter monitoring.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means checking static pressure limit, overload margin and impulse lines.

What We Did

We took a pressure range approach — pressure solution matched to process pressure and temperature. Delivery was built around checking static pressure limit, overload margin and impulse lines, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — filters changed on pressure drop, using cartridges to their full life, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Differential Pressure Measurement — Application Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Differential Pressure Measurement, focusing on differential pressure for flow and filter monitoring.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Differential Pressure Measurement specification must therefore cover checking static pressure limit, overload margin and impulse lines.

Delivery Approach

Delivery was handled as the pressure range — pressure solution matched to process pressure and temperature. Execution centred on checking static pressure limit, overload margin and impulse lines, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — filters changed on pressure drop, using cartridges to their full life, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · Differential Pressure Measurement — Application Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Differential Pressure Measurement; the focus is differential pressure for flow and filter monitoring.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with checking static pressure limit, overload margin and impulse lines.

Implementation

The scope ran through the pressure range: pressure solution matched to process pressure and temperature. Technically it hinges on checking static pressure limit, overload margin and impulse lines, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means filters changed on pressure drop, using cartridges to their full life, which cut the workload on the site maintenance team.